Preferred Language
Articles
/
fhefCpEBVTCNdQwCvZJA
Effective working parameters of laser micro-/nano-machining
...Show More Authors

Modern emerged technologies impose development and fabrication of miniatur-ized parts and devices in the micro- and nano-scale. Producing micro- and nano-featured structures requires nonconventional machining processes where con-ventional machining processes such as grinding, milling and eroding have failed. New emerging processes, such laser machining processes, are still fraught with almost invincible processes. Micro-/nano-machining are the pro-cesses of producing parts, microsystems or features at a scale of a few microm-eters and less than one hundred nanometers, respectively. Precise cutting and clean material removal accompanied with a negligible heat affected zone (HAZ), which are usually the characteristics of laser ablation, have opened a wide door for the evolution of remarkable technologies. This has been demonstrated by applications in different fields such as medicine, biotechnology, materials pro-cessing, microelectromechanical systems, electronics and communications. The continuous development in laser technology in terms of ultra-short pulse width, short wavelength and optics technologies has reduced the drawbacks of diffrac-tion-limited processing accuracies. Laser micro-/nano-machining requires the attainment of high fluence and short interaction time to achieve ablation pro-cesses in nanofabrication and structuring of different materials. To conduct the optimum desired machining process, it is important to integrally consider a number of laser beam and working parameters. Laser wavelength, beam mode, minimum attainable spot size, peak power, pulse duration, pulse repetition rate and scanning speed are some of the important considerations. Manipulating those parameters is crucial for ideal laser ablation represented by yielding the highest resolution of machining with the least lateral dimensions, acceptable depth and minimal or no melt at the edges. The assembly of laser beam delivery and focusing system with an automation system are the essential factors for workpiece positioning and obtaining the desired dimensions. The objective of this chapter is to review the effective parameters associated with laser machin-ing processes that affect the dimensions and quality of laser machining at the micro-/nano-scales in a simple presentation. The review is supported by demonstrating laser processing techniques applied in the field of micro-/nano-machining such as mask, interferometric and scribing techniques.

Crossref
View Publication
Publication Date
Mon Jan 01 2018
Journal Name
Ultramicroscopy
Characterization of trapped charges distribution in terms of mirror plot curve
...Show More Authors

View Publication
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Oct 12 2018
Journal Name
International Journal Of Medical Research & Health Sciences
A Comparison of Fear Levels of Endodontic Treatment in Iraqi Population
...Show More Authors

Introduction: Dental fear is defined as the patient’s specific reaction towards stress related to dental treatment in which the stimulus is unkn..

View Publication Preview PDF
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Effect the combination of antibiotics on clinical isolates of Staphylococcus aureus
...Show More Authors

Atotal of 75 different clinical samples were collected from different hospitals in Baghdad Biochemical and morphological characterization tests showed that forty isolates were identified as Staphylococcus aureus Antibiotic susceptibility tests of all isolates towards ten antibiotics were carried out and results showed that many isolates (97.5 %) were resistant to ?-lactam antibiotic , 70 % were resistant to Tetracyclinee , 62.5% were resistant to co-trimoxazole , 60 % were resistant to ciprofloxacin , 55% were resistant both of chloramphenicol and erythromycin , 52.5% were resistant to gentamicin , 35% were resistant to rifampicin , 10% were resistant to vancomycin . According to the above results the S.aureus I1 which is isolated

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Aug 10 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the esthetic smile in a sample of Iraqi population
...Show More Authors

Background: The aim of the present study is to evaluate the esthetic smile in sample of Iraqi adults and to assess the gender differences. Materials and Methods: 100 persons (50malesand 50 females had class I normal dental and skeletal selected for this study.Clinical examination and digital photograph with posed smile were performed for each individual. Six linear soft tissue parameters in each photograph using AutoCAD program 2011. Five visual and four quantitative evaluations of the smile were studied for eachsubject. The smile arch and index, buccal corridor spaces (BCSs) were studied.Descriptive statistics of the measurements were calculated. Independent student’s ttestswere used to evaluate the gender differences. Statistics: Desc

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 01 2020
Journal Name
Technology Reports Of Kansai University
Lascoux Resolution of Weyl Module in the Case of Partition (5,4,4)
...Show More Authors

Publication Date
Wed Jan 01 2020
Journal Name
2nd International Conference On Materials Engineering & Science (iconmeas 2019)
New application of pervaporation to enhance the conversion of consecutive reaction
...Show More Authors

This study investigates consecutive reaction assisted by pervaporation for the first time. It studies the saponification of diethyladipate DA with sodium hydroxide NaOH solution synchronous with separating ethanol from the reaction mixture through an aqueous – organic membrane. The effect of time on some variables such as: permeated ethanol concentration EtOH wt%, separation factor (α), concentration of NaOH solution CB in the reaction medium and the conversion of DA to monoethyladipate (the intermediate product) was studied. It was shown that EtOH wt% and the conversion increased with increasing time unlike CB but (α) showed the existence of maximum value during the time of experiment. The process of reaction assisted by pervaporation

... Show More
View Publication
Scopus Crossref
Publication Date
Thu Dec 28 2017
Journal Name
Al-khwarizmi Engineering Journal
Mathematical Modeling of Glucose Regulation System in Term of Perturbed Coefficients
...Show More Authors

In this research a recent developed practical modeling technique is applied for the glucose regulation system identification. By using this technique a set of mathematical models is obtained instead of single one to compensate for the  loss of information caused by the optimization technique in curve fitting algorithms, the diversity of members inside the single set is interpreted in term of restricted range of its parameters, also a diagnosis criteria is developed for detecting any disorder in the glucose regulation system by investigating the influence of variation of the parameters on the response of the system, this technique is applied in this research practically  for 20 cases with association of  National Center for

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 14 2019
Journal Name
Heat Transfer-asian Research
Characteristics of heat transfer of impingement system with swap swirl generator
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
The axial profile of plasma characteristics of cylindrical magnetron sputtering device
...Show More Authors

In the present work, a d.c. magnetron sputtering system was designed and fabricated. The chamber of this system was includes from two copper coaxial cylinders where the inner one used as a cathode (target) while the outer one used as the anode with Solenoid magnetic coil located on the outer cylinder (anode). The axial profile of magnetic field for various coil current (from 2A to 14 A) are shown. The plasma characteristics in the normal glow discharge region are diagnostics by the 2.2mm diameter Langmuir probe with different length along the cathode and located at different radial positions 1cm and 2cm from the cathode surface. The result of this work shows that, the electron energy distributions at different radial positions along the

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Political Sciences Journal
Impact of the Rising of China in Restructuring the International System
...Show More Authors

It is no secret to everyone that the Arab individual suffers from poor self-awareness and political awareness, which made the state and the importance of its existence and preserving its institutions not among his interests, which made researchers wonder about the possibility of strengthening it and the extent of its impact on the future of building the contemporary Arab state. So, the study attempts to addressing the issue of community awareness and its impact on building the state through a clear intellectual vision that blended what is social and political to define the concept of community awareness and highlight its importance and role as a basic pillar in shaping and building modern Arab countries in the Arab world and ways to enha

... Show More
View Publication Preview PDF
Crossref