Preferred Language
Articles
/
fhb9AIgBVTCNdQwC83JO
BC2N nanotube as a promising anode for rechargeable calcium ion batteries
...Show More Authors

Because of cost-effective production and abundant resources of calcium, Ca-ion batteries (CIBs) are an appropriate option to alternate Li-ion batteries (LIBs). A new category of anode materials for CIBs has emerged since the successful synthesis of carbon nanotubes, which are B and N doped derivatives of it. For high-performance CIBs, BC2N nanotube (BC2NNT) has been studied as promising anode materials. In order to comprehend electrochemical attributes, cycling stability, and adsorption behavior of BC2NNT, first-principles computations have been executed. Based on nuclear magnetic resonance computations, two types of hexagonal rings (B2C2N2 (I) and BC4N (II)) were specified that are non-aromatic. Ca has adsorption on B2C2N2 and BC4N with adsorption energy (Ead) values of −47.44 and −28.50 kcal/mol, respectively. Specific capacity value has been determined to be as high as 840 mAh/g. The predicted average open-circuit voltage (OCV) for BC2NNT is 1.56 V, which has a larger value than that of other 2D materials. All mentioned reasons provide BC2NNT as an acceptable anode material for use in CIBs. In present research, results may create new ways of designing favorable boron-carbon-nitrogen based anode materials for CIBs.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Dec 01 2010
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Technical methodology balanced performance as a strategic framework for the economic units operating in the Iraqi industrial sector environment
...Show More Authors

facing economic units operating in the environment sector of the Iraqi

industrial many pressures in its seeking to measure and evaluate its performance because of variables, today's corporate environment, as the case which makes looking for a methodology can be adopted to evaluate its performance with a more holistic, rather than being limited to traditional measures that are no longer enough to keep pace with rapid changes in today's corporate environment, which requires that measures of performance are derived from the strategy of unity and commensurate with the specificity of the environment in Iraq. Try searching discussion Ttormwhrat and performance measurement systems to suit the business strategies and directions of change

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 28 2023
Journal Name
Mathematical Modelling Of Engineering Problems
Using Crushed Glass with Sand as a Single and Dual Filter Media for Removal of Turbidity from Drinking Water
...Show More Authors

View Publication
Publication Date
Sun Dec 17 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study Using the Passive Solar Chimney for Evaporative Cooling With PCM and CFM as a Thermal Energy Storage
...Show More Authors

 

      In this work, a test room was built in Baghdad city, with (2*1.5*1.5) m3  in dimensions, while the solar chimneys (SC) were designed with aspect ratio (ar) bigger than 12. Test room was supplied by many solar collectors; vertical single side of air pass with ar equals 25, and tilted 45o double side of air passes with ar equals 50 for each pass, both collectors consist of flat thermal energy storage box collector (TESB) that covered by transparent clear acrylic sheet, third type of collector is array of evacuated tubular collectors with thermosyphon in 45o instelled  in the bottom of TESB of vertical SC. The TESB was

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The reliability of insertion torque as an indicator for primary stability in immediate dental implant: A prospective clinical study
...Show More Authors

Background: The primary stability of the dental implant is a crucial factor determining the ability to initiate temporary implant-supported prosthesis and for subsequent successful osseointegration, especially in the maxillary non-molar sites. This study assessed the reliability of the insertion torque of dental implants by relating it to the implant stability quotient values measured by the Osstell device. Material and methods: This study included healthy, non-smoker patients with no history of diabetes or other metabolic, or debilitating diseases that may affect bone healing, having non-restorable fractured teeth and retained roots in the maxillary non-molar sites. Primary dental implant stability was evaluated using a torque ratc

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Microporous And Mesoporous Materials
Using the ash of common water reeds as a silica source for producing high purity ZSM-5 zeolite microspheres
...Show More Authors

View Publication
Scopus (38)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Wed Oct 29 2025
Journal Name
The Indonesian Biomedical Journal
Genotype Combination of rs1042044 and rs6458093 in GLP-1R as A Genetic Risk for Osteoporosis in Postmenopausal Iraqi Women
...Show More Authors

BACKGROUND: Many genetic factors are known to be related to osteoporosis, and currently the role of the glucagon-like peptide-1 receptor (GLP-1R) gene in bone health has been studied intensively. Some variation of this gene, such as rs1042044 and rs6458093, are known to be linked to metabolic diseases and lower bone mineral density, however their specific contribution to osteoporosis remains largely unexplored. Therefore, this study was conducted to investigate the combined genotypic effect of rs1042044 and rs6458093 as a genetic risk factor for osteoporosis in postmenopausal Iraqi women.METHODS: Blood samples from 75 osteoporosis patients and 75 healthy controls, aged 45-85, were collected. DNA was extracted, and a region of GLP-1R

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sun Mar 06 2011
Journal Name
Baghdad Science Journal
The Calculation of the partical distribution function g(r12,r1) for Carbon Ion cases (C+2,C+3,C+4) in the position space
...Show More Authors

The aim of this work is study the partical distribution function g(r12,r1) for Carbon ion cases (C+2,C+3,C+4) in the position space using Hartree-Fock's Wave function, and the partitioning technique for each shell which is represented by Carbon Ions [C+2 (1s22s2)], [C+3 (1s22s)] and [C+4 (1s2)]. A comparision has been made among the three Carbon ions for each shell. A computer programs (MATHCAD ver. 2001i) has been used texcute the results.

View Publication Preview PDF
Crossref
Publication Date
Wed Aug 28 2024
Journal Name
World Academy Of Sciences Journal
Serum angiopoietin‑1 as a biomarker of missed miscarriage
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Terrestrial Invertebrates as a Bioindicators of Heavy Metals Pollution
...Show More Authors

Bioaccumulation of heavy metals in the terrestrial invertebrates in Al-Jadriyia district Baghdad- Iraq were investigated. Forth terrestrial invertebrates snails, slug, isopods, and diplopods , were selected for this study. The results showed that all invertebrate groups have the ability in accumulate considerable amounts of heavy metals. Higher levels of zinc and copper were observed in the isopods specimens, it's about ( 60.50±0.58 ) and ( 96.00±0.58 ) ppm respectively , while higher levels of lead were observed in the diplopods specimens ,it's about ( 23.00±1.15 ) ppm ,but the higher levels of both iron and cadmium were observed in snail specimens , it's about ( 590.00±1.15 ) and ( 9.50±1.15 ) ppm respectively .but the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Spectrophotometrically Analysis of PMMA as a low – Doses Dosimeter
...Show More Authors

Polymethylmethacrylate film (PMMA) of thickness 75 μm was evaluated Spectrophotometrically for using it as a low-doses gamma radiation dosimeter. The doses were examined in the range 0.1 mrad-10 krad. Within an absorption band of 200-400 nm, the irradiated films showed an increase in the absorption intensity with increasing the absorbed doses. Calibration curves for the changes in the absorption differences were obtained at 218, 301, and 343 nm. At 218 nm the response for the absorbed doses is a linear in the range 10 mrad- 10 krad. Hence it is recommended to be adopted as an environmental low doses dosimeter

View Publication Preview PDF