Preferred Language
Articles
/
fRdWX5MBVTCNdQwCINJY
Evaluation of the Effect of Type II Diabetes mellitus on Bone Mineral Density of Upper and Lower Limbs by Dual-Energy X-Ray Absorptiometry
...Show More Authors

Background: Bone mineral density has been assessed using Dual-Energy X-Ray Absorptiometry. Bone mineral density is measured according to the results of the Dual-Energy X-Ray Absorptiometry examination of the vertebral column and pelvis. Although diabetes mellitus type II (DM) is known to affect bone mineral density, at the present time this particular relationship is not clear. Objective: The aim of current study was to evaluate the effects of type II diabetes mellitus on bone mineral density of the upper and lower limbs as well as gender differences. Patients and Methods: This study involved 165 patients complaining of bone pain (85 males and 80 females), 85 patients of who suffered from diabetes, involving both genders. In addition, 90 apparently healthy volunteers had been studied and were considered to constitute the control group. All individuals (255) were studied regarding their bone mineral density via Dual-Energy X-Ray Absorptiometry for all parts of the body. Results: The Dual-Energy X-Ray Absorptiometry exam revealed highly statistically significant differences between the sides of the body in the same person. In addition, there were significant differences in bone mineral density between females and males, as well as between the control and patient groups with type II diabetes mellitus. Conclusion: Our results indicated that the bone mineral density of women was less than that in men in all cases (normal, osteoporosis, and diabetes mellitus type II (DM) with osteoporosis). Other results obtained from this research revealed that diabetes mellitus type II (DM) can be considered to be one of the major causes of osteoporosis in the general population

Publication Date
Fri Mar 01 2024
Journal Name
Journal Of Water Process Engineering
Chitosan-vermiculite composite adsorbent: Preparation, characterization, and competitive adsorption of Cu(II) and Cd(II) ions
...Show More Authors

The cost-effective removal of heavy metal ions represents a significant challenge in environmental science. In this study, we developed a straightforward and efficient reusable adsorbent by amalgamating chitosan and vermiculite (forming the CSVT composite), and comprehensively investigated its selective adsorption mechanism. Different techniques, such as Fourier-transform infrared spectroscopy (FTIR), zeta potential analysis, scanning electron microscopy (SEM), X-ray diffraction (XRD), and Brunauer, Emmett, Teller (BET) analysis were employed for this purpose. The prepared CSVT composite exhibited a larger surface area and higher mesoporosity increasing from 1.9 to 17.24 m2/g compared to pristine chitosan. The adsorption capabilities of the

... Show More
View Publication
Scopus (40)
Crossref (39)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Journal Of Ecological Engineering
Dual Application of Al-Kheriat of Removal of Arsenic from Aqueous Solution and Acting as Rodenticide
...Show More Authors

Arsenic is a prevalent and pervasive environmental contaminant with varied amounts in drinking water. Arsenic exposure causes cancer, cardiovascular, liver, nerve, and ophthalmic diseases. The current study aimed to find the best conditions for eliminating arsenic from simulated wastewater and their effect on biomarkers of hepatic in mice. Adsorption tests including pH, contact duration, Al-kheriat dosage, and arsenic concentrations were evaluated. Seventy-two healthy albino mice (male) were accidentally allocated into nine groups (n = 8), the first group was considered as healthy control, the second group (AL-Kheriat), and other groups received AL-Kheriat and arsenic 25, 50, 75, 100, 125, 150 and 175 mg/kg, respectively. Next 10 days, the

... Show More
Crossref (2)
Crossref
Publication Date
Tue Dec 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Spectral Study of Pt (II), Cr (II) Polymeric Complexes of the Ligand N- Crotonyl -2- Hydroxy-Phenylazomethine
...Show More Authors

 The polymeric complexes were obtained from the reaction of polymeric Schiff base.N-crotonyl-2-hydroxyphenylazomethine (HL), with divalent metals Pt (II), Cr (II). The modes of bonding and overall geometry of the complexes were determine through spectroscopic methods and compared with that reported from analogous monomeric ligand. This study revealed square planer geometry around the metal center for [Pt(L)Cl] and distorted octahedral geometry for Cr complex [Cr(L)Cl(H2O)2].

View Publication Preview PDF
Publication Date
Fri Nov 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation the antioxidant effect of ?-L- Fucose injection into rabbit periodontium
...Show More Authors

Background: ?-L-Fucose is a methyl pentose sugar similar to L-galactose except for the loss of alcohol group on carbon number 6. The objective of this study is to evaluate the biochemical and antioxidant effect of intracrevicular injection of fucose into rabbits periodontium, throughout measuring the levels of total protein (TP), total fucose (TF), protein bound fucose PBF) , Malondialdehyde (MDA) , and vitamin C in sera of fucose injected rabbit groups. ) Materials and Methods: The existing study was carried out on 55 male rabbits and were divided randomly into three groups ; first group was injected with 50µl of 150mM fucose solution into gingival sulcus ; second group was injected with 50 µl of normal saline ; while the third group was

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Baghdad Science Journal
Impacts of Denial-of-Service Attack on Energy Efficiency Pulse Coupled Oscillator
...Show More Authors

The Pulse Coupled Oscillator (PCO) has attracted substantial attention and widely used in wireless sensor networks (WSNs), where it utilizes firefly synchronization to attract mating partners, similar to artificial occurrences that mimic natural phenomena. However, the PCO model might not be applicable for simultaneous transmission and data reception because of energy constraints. Thus, an energy-efficient pulse coupled oscillator (EEPCO) has been proposed, which employs the self-organizing method by combining biologically and non-biologically inspired network systems and has proven to reduce the transmission delay and energy consumption of sensor nodes. However, the EEPCO method has only been experimented in attack-free networks without

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Thu Jan 04 2018
Journal Name
International Journal Of Molecular Sciences
Understanding the Progression of Bone Metastases to Identify Novel Therapeutic Targets
...Show More Authors

View Publication
Scopus (39)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
The nuclear level density parameter
...Show More Authors

The nuclear level density parameter  in non Equi-Spacing Model (NON-ESM), Equi-Spacing Model (ESM) and the Backshifted Energy Dependent Fermi Gas model (BSEDFG) was determined for 106 nuclei; the results are tabulated and compared with the experimental works. It was found that there are no recognizable differences between our results and the experimental -values. The calculated level density parameters have been used in computing the state density as a function of the excitation energies for 58Fe and 246Cm nuclei. The results are in a good agreement with the experimental results from earlier published work.

View Publication Preview PDF
Crossref
Publication Date
Mon Dec 01 2008
Journal Name
Al-khwarizmi Engineering Journal
Performance of Gas Induction in a Dual – Impeller Agitated Bioreactor
...Show More Authors

The rate of gas induction was measured in gas-inducing type mechanically agitated contactors provided with two impellers. A reactor of 0.5 m i.d. was used with a working capacity of 60 liters of liquid. Tap water was used as the liquid phase, and air was used as the gas phase. The bioreactor mixing system consists of two equal diameter stirrers; the top impeller is shrouded-disk/curved-blade turbine with six evacuated bending blades, while the bottom impeller was disk turbine. The impeller speed was varied in the range of 50 to 800 rpm. The ratio of impeller diameter to tank diameter (D/T) and the submergence (S) of upper impeller from the top were varied. The effects of clearance of lower impeller from the tank bottom (C2) an

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Effect of Laser Irradiation on the Optical Properties of SnO2 films Deposited by Post Oxidation of metal Films
...Show More Authors

Tin oxide films (SnO2) of thickness (1 ?m) are prepared on glass substrate by post oxidation of metal films technique. Films were irradiated with Nd:YAG double frequency laser of wavelength (532 nm) pulses of three energies (100, 500, 1000) mJ. The optical absorption, transmission, reflectance, refractive index and optical conductivity of these films are investigated in the UV-Vis region (200-900) nm. It was found that the average transmittance of the films is around (80%) at wavelength (550 nm) and showed high transmission (? 90 %) in the visible and near infrared region. The absorption edge shifts towards higher energies, which is due to the Moss-Burstien effect and it lies at (4 eV). The optical band gap increased with increasing of ene

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2022
Journal Name
Biochemical And Cellular Archives
EVALUATION OF THE TOXICITY OF DELTAMETHRIN INSECTICIDE ON SOME HEMATOLOGICAL PARAMETERS AND OXIDATIVE STRESS ON MICE
...Show More Authors