Objectives To tailor composites of polyethylene–hydroxyapatite to function as a new intracanal post for the restoration of endodontically treated teeth (ETT). Methods Silanated hydroxyapatite (HA) and zirconium dioxide (ZrO2) filled low-density polyethylene (LDPE) composites were fabricated by a melt extrusion process and characterised using infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). The flexural strength and modulus were determined in dry state and post ageing in simulated body fluid and fractured surfaces analysed by SEM. The water uptake and radiographic appearance of the experimental composites were also measured and compared with a commercially known endodontic fibre post. Data were submitted to one-way analysis of variance (ANOVA) and post hoc Tukey multiple comparison tests at a level of significance P < 0.05. Results The LDPE/HA composites were structurally flexible and the HA content had a significant effect on the flexural strength and modulus. A univariate analysis of variance showed no significant differences in modulus and strength (P < 0.05) post accelerated ageing in simulated body fluid with very low water uptake. The melting point of the LDPE/HA composites ranged between 135 and 136 °C, which would facilitate removal in case of retreatment using conventional dental heating devices. The inclusion of HA reduced the damping thereby enhancing dimensional stability, whilst the addition of zirconia yielded a semi-translucent material that was sufficiently radiopaque, comparable to commercial posts, thus yielding aesthetic materials. Conclusions Innovative materials for restoration of ETT were developed; offering considerable benefits over the currently available material in terms of biomechanical and thermal properties. Clinical significance This study provided a new option for the development of a new intracanal post made up of functional and aesthetic composites.
Background: Treatment of invasive prolactinoma, which has several characteristics including invasive growth into cavernous sinuses and formation of giant adenomas compressing adjacent neural structures, resulting in neurological dysfunction, has been very challenging. There are relatively few reports available describing long-term treatment outcome.
Aims of the study: In this study we evaluate the results of cabergoline administration as initial treatment during 4 years follow up period.
Methods: We prospectively categorized 36 patients into four groups according to the results of 3 months of cabergoline treatment: group 1, tumor volume reduction (TVR) ˃25% with normaliz
... Show MoreGypseous soils represented one of the most complex salty soils that faced the geotechnical engineers. Structures that built on gypsum soil will undergo unexpected distortions that will eventually contribute to catastrophic failure. The purpose of this article is to understand the durability of gypsum soil against wetting drying cycles after improvement with polyurethane polymer especially investigate the effect of the wetting-drying cycle on collapsibility. The soil was brought from Sawa lake in AL-Muthanna Governorate in Iraq, with gypsum content 65.5%, A set of Odometer tests were performed to determine the collapsibility potential (CP) for treated and untreated gypsum soil. The result shows that adding a different per
... Show MoreBackground: The most crucial mechanism of genetic variation in N. meningitidis is the slipped strand mispairing, this mechanism generates Phase variation using simple sequence repeat (SSR) and is commonly used by the N. meningitidis to escape the immune system despite its function in eradicating the pathogenic and commensal bacteria. Some of simple sequence repeats (SSRs) that located within the genome works as phase variation while other SSRs have no role in generating phase variation mechanisms. Therefore, Aim: the main goal of the current in silico study was to detect the probability of SSR to enroll with phase variation for the entire N. meningitidis genome. Methods: Different criteria were used to judge SSR as
... Show MoreIn this investigation , borax (B) (additive I) and chlorinated paraffin (CP.) (additive II) ,were used as flame retardants for each of epoxy and unsaturated polyester resins in the weight ratios of 2,4,6, & 8% by preparing films of (130×130×3) mm dimensions. Also films of these resins with a mixture of [50%(B.)+50%(CP.)] (additive III) in the same weight ratios were prepared in order to study the synergistic effect of these additives on the flammability of the two resins . Three standard test methods were used to measure the flame retardation which are : 1-ASTM : D-2863 2-ASTM : D-635 3-ASTM : D-3014
... Show MoreABSTRACT: BACKGROUND: The main goal of facelift surgery is to reduce the effect of aging by reposition of face soft tissue in to more youthful orientation. There are many methods for SMAS plication which had different design and vector of pull. AIM OF STUDY: To evaluate the effectiveness and longitivity of 7 shaped SMAS plication in facelift. PATIENT AND METHODS: From January 2020 to march 2021, 10 female patients with age (45-60) years were presented with facial sagging, those patients were subjected to subcutaneous facelift with 7 shaped SMAS plication with fat greft in Al-Shaheed Ghazi Al-Harri Hospital and Baghdad burn medical center at Baghdad medical complex. RESULTS: The average follow up period was 6 to 12 months. The mean operative
... Show MoreBackground: Implant stability is a mandatory factor for dental implant (DI) osseointegration and long-term success. The aim of this study was to evaluate the effect of implant length, diameter, and recipient jaw on the pre- and post-functional loading stability. Materials and methods: This study included 17 healthy patients with an age range of 24-61 years. Twenty-two DI were inserted into healed extraction sockets to replace missing tooth/ teeth in premolar and molar regions in upper and lower jaws. Implant stability was measured for each implant and was recorded as implant stability quotient (ISQ) immediately (ISQ0), and at 8 (ISQ8) and 12 (ISQ12) weeks postoperatively, as well as post-functional loading (ISQPFL). The pattern of implant
... Show More