The dependence of the energy losses or the stopping power for the energies and the related penetrating factor are arrive by using a theoretical approximation models. in this work we reach a compatible agreement between our results and the corresponding experimental results.
The use of heavy ions in the treatment of cancer tumors allows for accurate radiation of the tumor with minimal collateral damage that may affect the healthy tissue surrounding the infected tissue. For this purpose, the stopping power and the range to which these particles achieved of Nitrogen (N) in the skin tissue were calculated by programs SRIM (The Stopping and Range of Ions in Matter),(SRIM Dictionary) [1],(CaSP)(Convolution approximation for Swift Particles )[2]which are famous programs to calculate stopping power of material and Bethe formula , in the energy range (1 - 1000) MeV .Then the semi - empirical formulas to calculate the stopping power and range of Nitrogen io
... Show More
We apply a semi classical partial-wave scattering method based on the induced density approach (IDA) model. For ion electron scattering, the transport cross section is used to calculate the energy loss. This method yields a non-perturbative exemplification of energy loss, bridging the difference among classical and quantal representations. The focus of this work is the interaction of hetero nuclear di-cluster (He-H) ions with a free gas. The results show three kinds of stopping power in (a.u) (cluster stopping power, self-stopping power and correlated stopping power) of hetero nuclear di-cluster ions (He-H) with velocity at different atomic di-cluster distances at different densities and temperatures. We find that Bragg’
... Show MoreIn this work, the electrostatic probe was utilized to estimate the density of electrons for plasma generated around reentry vehicles that have a geometrically blunt nose at high-altitude. The thermocouple uses to measured electron temperature, which is equal to the temperature of the gas, on board the MAC spacecraft. In the spacecraft backflow field, electrostatic probe measurements were taken at five separate regions 1 to 5 cm from the body of the spacecraft. Over an altitude range of 90 to 50 km with an electron density of 108 to 1012 1/cm3, respectively. The measured electron temperature ranged from 0.05 to 0.9 electron volts and the maximum re-entry velocity of the spacecraft was about 7048 m
... Show MoreThe research aims to shed light on the importance of Natural gas as a National wealth is not being used optimally to be a financial resource is important to Iraq in addition to Oil, as well as could be used as an important Source of Energy, instead of burning gas is a waste of wealth and Contribute to the contamination of the environment. Research Reviews the importance of Natural gas, where is currently about a quarter of global energy consumption. Then deals with the reality of the gas industry in Iraq and winning because of the volume of waste incineration, which reached a rate (45%) of the gas Associated with oil, where Iraq is fourth globally in Terms of the amount of gas Burned. Finally, this paper discusses the future of n
... Show MoreIn this work, we studied the effect of power variation on inductively coupled plasma parameters using numerical simulation. Different values were used for input power (750 W-1500 W), gas temperature 300K, gas pressure (0.02torr), 5 tourns of the copper coil and the plasma was produced at radio frequency (RF) 13.56 MHZ on the coil above the quartz chamber. For the previous purpose, a computer simulation in two dimensions axisymmetric, based on finite element method, was implemented for argon plasma. Based on the results we were able to obtain plasma with a higher density, which was represented by obtaining the plasma parameters (electron density, electric potential, total power, number density of argon ions, el
... Show MoreIn this work; Silicon dioxide (SiO2) were fabricated by pulsed
laser ablation (PLA). The electron temperature was calculated by
reading the data of I-V curve of Langmuir probe which was
employed as a diagnostic technique for measuring plasma properties.
Pulsed Nd:YA Glaser was used for measuring the electron
temperature of SiO2 plasma plume under vacuum environment with
varying both pressure and axial distance from the target surface. The
electron temperature has been measured experimentally and the
effects of each of pressure and Langmuir probe distance from the
target were studied. An inverse relationship between electron
temperature and both pressure and axial distance was observed.
In this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.
In this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in high distance
... Show MoreIn this work, electron number density calculated using Matlab program code with the writing algorithm of the program. Electron density was calculated using Anisimov model in a vacuum environment. The effect of spatial coordinates on the electron density was investigated in this study. It was found that the Z axis distance direction affects the electron number density (ne). There are many processes such as excitation; ionization and recombination within the plasma that possible affect the density of electrons. The results show that as Z axis distance increases electron number density decreases because of the recombination of electrons and ions at large distances from the target and the loss of thermal energy of the electrons in
... Show MoreThe main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu
... Show More