Treated effluent wastewater is considered an alternative water resource which can provide an important contribution for using it in different purposes, so, the wastewater quality is very important for knowing its suitability for different uses before discharging it into fresh water ecosystems. The wastewater quality index (WWQI) may be considered as a useful and effective tool to assess wastewater quality by indicating one value representing the overall characteristic of the wastewater. It could be used to indicate the suitability of wastewater for different uses in water quality management and decision making. The present study was conducted to evaluate the Al-Diwaniyah sewage treatment plant (STP) effluent quality based on wastewater quality index (WWQI) for disposal according to Iraqi limitations. Wastewater samples were collected from Al-Diwaniyah STP during 2012-2016 and tested for a comprehensive analysis of physical and chemical analysis. The parameters included Total suspended solids (TSS), Nitrate (NO3), Biological oxygen demand (BOD5), and Chemical oxygen demand (COD). The determination of the WWQI was done using the weighted arithmetic method. The results showed that the effluent BOD5, COD and TSS concentrations were not in the Iraqi standards for effluent disposal. The WWQI of this effluent classified its quality within ranged from poor to very poor according to Iraqi standards (IQS) and very poor to very polluted under the world health standards (WHO), that could cause environmental pollution in the receiving river. The permanent solution is through the proper operation using scientific methods and training the operational staff using technical methods and then future solution, advanced treatment in the plant, by completing both the solutions above will lead to upgrade the effluent quality to achieve the required water standards.
Baghdad city has been faced numerous issues related to freshwater environment deteriorations due to many reasons, mainly was the discharge of wastewater without adequate treatment. Al- Rustamiya Wastewater Treatment Plant (WWTP) have been constructed among many plants in Baghdad city to reduce the amount of wastewater discharged into natural environment and its subsequent adverse effects. This study was conducted to evaluate the performance of the plant which consist of a conventional activated sludge (CAS) and sequencing batch reactors (SBR) systems as secondary treatment units and its ability to meet Iraqi specifications. A reliability level determination and analysis also were conducted to find the plant's stability and its capabi
... Show MoreBaghdad city has been faced numerous issues related to freshwater environment deteriorations due to many reasons, mainly was the discharge of wastewater without adequate treatment. Al-Rustamiya Wastewater Treatment Plant (WWTP) have been constructed among many plants in Baghdad city to reduce the amount of wastewater discharged into natural environment and its subsequent adverse effects. This study was conducted to evaluate the performance of the plant which consist of a conventional activated sludge (CAS) and sequencing batch reactors (SBR) systems as secondary treatment units and its ability to meet Iraqi specifications. A reliability level determination and analysis also were conducted to find the plant's stability an
... Show MoreThe present study deals with the assessment of water Quality Index to theAl-
Khadhimiya Groundwater city, by collection groundwater from 13wells during four
seasons, subjecting the samples to a comprehensive physicochemical analysis. The
13 parameters have been considered: pH, total hardness, calcium, magnesium,
turbidity, nitrate, electrical conductivity, total dissolved solid, Sulfate, Chloride,
zinc, manganic, and iron, that are used for calculating the WQI. From the result
shown, the most groundwater quality lies in Unfit for human drinking purpose. The
wells (1 and 11) and wells (3 and 10) were a bad water quality for drinking purpose
since they lie in poor and in very poor respectively according to the WQI.
Inefficient wastewater disposal and wastewater discharge problems in water bodies have led to increasing pollution in water bodies. Pollutants in the river contribute to increasing the biological oxygen demand (BOD), total suspended solids (SS), total dissolved solids (TDS), chemical oxygen demand (COD), and toxic metals render this water unsuitable for consumption and even pose a significant risk to human health. Over the last few years, water conservation has been the subject of growing awareness and concern throughout the world, so this research focused on review studies of researches that studied the importance of water quality of wastewater treated disposal in water bodies and modern technology to management w
... Show MoreWater quality of Al-Gharraf River, which considered the main branch of Tigris River south of Iraq was examined using the Canadian Council of Ministers of the Environment Water Quality Index (CCME-WQI) for aquatic life protection and irrigation. Water samples were collected monthly from five sampling stations during 2013-2014 and 17 physicochemical parameters were analyzed: Temperature, hydrogen ion concentration (pH), electrical conductivity, dissolved oxygen, turbidity, alkalinity, chloride, calcium, magnesium, sulfate, phosphate, nitrate, sodium, lead, cadmium, nickel and zinc.
The model classified water of Al-Gharraf River as poor for aquatic life protection and fair for irrigation with seasonal overall WQI value of 30-39 and among
This study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in the study were
... Show MoreThis study was conducted to investigate the effects of Al-Rasheed power plant (RPP) effluents at Al-Zafaraniya city on the physical – chemical of the Tigris River by using Canadian Water Quality Index(CCME WQI).Water samples were taken monthly at four positions and 11parameters were analyzed . The results of this study conducted that there was a significant impact of the RPP effluents on increase of water temperature, turbidity and electrical conductivity, and there was an increase in the phosphate concentration and water hardness at station 2 and the model classified water of Tigris river as poor in winter and fair to marginal in rest season for drinking and aquatic life
Al-Rustamiya sewage treatment plant (WWTP) serves the east side of Baghdad city (Rusafa) and is considered one of the largest projects.It consists of three parts (old project F0, first extension F1, and second extension F2) that treat wastewater and the
effluent is discharged into Diyala river and thus into the Tigris River. These plants are designed and constructed with an aim to manage wastewater to reachIraqi effluent standard for BOD5, COD, TSS and chloride concentrations of 40, 100, 60 and 600
mg/L respectively. The data recordedfrom March till December 2011 provided from Al-RustamiyaWWTP, were considered in this study to evaluate the performance of the plant. The results indicated that the strength of the wastewater enterin
This study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in th
... Show More