Carbonate matrix stimulation technology has progressed tremendously in the last decade through creative laboratory research and novel fluid advancements. Still, existing methods for optimizing the stimulation of wells in vast carbonate reservoirs are inadequate. Consequently, oil and gas wells are stimulated routinely to expand production and maximize recovery. Matrix acidizing is extensively used because of its low cost and ability to restore the original productivity of damaged wells and provide additional production capacity. The Ahdeb oil field lacks studies in matrix acidizing; therefore, this work provided new information on limestone acidizing in the Mishrif reservoir. Moreover, several reports have been issued on the difficulties encountered during the stimulation operation of the Ahdeb oil field, particularly for the development of the Mishrif reservoir. Since the new core flooding system is built to operate safely and straightforwardly. This study introduced the results of Matrix acidizing experiments, covering the most recent developments in linear core flooding. High-permeability flow pathways are created, and a longer and wider wormhole was generated at a high acid injection rate (6.67 cc/min). The acid efficiency curve yielded the lowest pore volume injected at the breakthrough of the PV_(bt-opt) is 2.73 and the v_(i-opt)=0.6 cm/min; thus, the optimum injection rate that results in an optimal possible wormhole and the least quantity of acid being used for this reservoir is 2.16 cc/min. This research evaluated the impact of matrix acidizing treatment on acoustic characteristics, which studies show are lacking or have never been investigated previously. Furthermore, in the assessment of geomechanical rock properties and elastic and petrophysical parameters before and after acid injection, one of the new concepts discovered during the lab experiment observation of the acoustic waveform before and after acid treatment for the tested rock sample is that the initial arrival time before acid treatment is 21.6 microseconds, with a delay of 31.2 microseconds attributed to the wormhole channel and mineral disintegration. CT-Scan applications in matrix acidizing were investigated in this research; additionally, a 3D view of plug samples was constructed to represent the wormhole extension via CT-processing software. A license of Stimpro Stimulation Software has been used to validate the experimental work to the field scale, making it the most comprehensive instrument for planning and monitoring matrix acid treatment and utilizing actual data to provide a far better knowledge of the well's reaction, with methods that represent the reality of what is happening in the reservoir before, during, and after matrix acid treatments, through the post-treatment skin factor which is the most often utilized statistic for analyzing stimulation treatments and relies on the geometry of the wormholed zone. The acid treatment evaluated for the well AD-12, primarily for the zone Mi4; matrix acid treatments can have their production behavior predicted or matched using the reservoir simulation and production analysis option, employing the numerical simulation license software Petrel (Schlumberger) and Rubis (KAPPA) to determine the efficacy of previous treatments and the economics associated with future treatments. The estimated oil gain volume and percentage for the Mi4 unit in Ad-12 using particularly skin value -3.97 computed from Stimpro software for real stimulation acid job, it is yield enhancement in production of oil gain volume 6154 barrels as well as 105% increase of gain percentage for three months after matrix acidizing.
This study successfully synthesized high-performance photodetectors based on Ag-WO3 core–shell heterostructures using a simple and economical two-step pulsed laser ablation in water method and has investigated the electrical characteristics of the Ag@WO3 nanocomposite heterojunction. The Hall effect tests indicate that the synthesized Ag@WO3 exhibits n-type conduction with a Hall mobility of 1.25 × 103 cm2V-1S-1. Dark current–voltage properties indicated that the created heterojunctions displayed rectification capabilities, with the highest rectification factor of around 1.71 seen at a 5 V bias. A photodetector’s responsivity reveals the existence of two response peaks, which are situated in the ultraviolet and visible region. The ph
... Show MorePosition control of servo motor systems is a challenging task because of inevitable factors such as uncertainties, nonlinearities, parametric variations, and external perturbations. In this article, to alleviate the above issues, a practical adaptive fast terminal sliding mode control (PAFTSMC) is proposed for better tracking performance of the servo motor system by using a state observer and bidirectional adaptive law. First, a smooth-tangent-hyperbolic-function-based practical fast terminal sliding mode control (PFTSM) surface is designed to ensure not only fast finite time tracking error convergence but also chattering reduction. Second, the PAFTSMC is proposed for the servo motor, in which a two-way adaptive law is designed to further s
... Show MoreUltraviolet photodetectors have been widely utilized in several applications, such as advanced communication, ozone sensing, air purification, flame detection, etc. Gallium nitride and its compound semiconductors have been promising candidates in photodetection applications. Unlike polar gallium nitride-based optoelectronics, non-polar gallium nitride-based optoelectronics have gained huge attention due to the piezoelectric and spontaneous polarization effect–induced quantum confined-stark effect being eliminated. In turn, non-polar gallium nitride-based photodetectors portray higher efficiency and faster response compared to the polar growth direction. To date, however, a systematic literature review of non-polar gallium nitride-
... Show MoreAlzheimer’s disease (AD) is a progressive disorder that affects cognitive brain functions and starts many years before its clinical manifestations. A biomarker that provides a quantitative measure of changes in the brain due to AD in the early stages would be useful for early diagnosis of AD, but this would involve dealing with large numbers of people because up to 50% of dementia sufferers do not receive formal diagnosis. Thus, there is a need for accurate, low-cost, and easy to use biomarkers that could be used to detect AD in its early stages. Potentially, electroencephalogram (EEG) based biomarkers can play a vital role in early diagnosis of AD as they can fulfill these needs. This is a cross-sectional study that aims to demon
... Show MoreBackground: The isthmus is a difficult area in the root canal complex to manage. The research aimed to evaluate the efficiency of three different obturation techniques (lateral condensation, EandQ (thermoplasticized gutta percha system) and Soft Core (thermoplasticized core carrier gutta percha system)) to obturate the isthmus area of roots prepared by two different instrumentation techniques (rotary ProTaper universal and ProTaper Next systems). Material and method: Sixty freshly extracted teeth were randomly divided into two main groups (A and B) of 30 teeth each. Group A was prepared by rotary ProTaper Universal whereas group B was prepared by ProTaper Next system. Each main group was then randomly subdivided into three subgroups of 10 t
... Show MoreBackground: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re
... Show MoreBackground: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re
... Show More