Preferred Language
Articles
/
fBZoRocBVTCNdQwCcED8
Effect of Topical Melatonin Application on the Peri-Implant Proximal Bone Level and Cortical Plate Thickness (Pilot Clinical Trial)
...Show More Authors

Publication Date
Fri Jun 01 2018
Journal Name
Current Medical Science
Biomechanical Evaluation of Nano-Zirconia Coatings on Ti-6Al-7Nb Implant Screws in Rabbit Tibias
...Show More Authors

View Publication
Crossref (16)
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Cosmetics, Dermatological Sciences And Applications
Topical 40% <i>Loranthus europaeus</i> Ointment as an Alternative Medicine in the Treatment of Acute Cutaneous Leishmaniasis versus Topical 25% Podophyllin Solution
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Fri Apr 01 2022
Journal Name
World Congress On Civil, Structural, And Environmental Engineering
Improving the Behavior of Steel Plate Shear Wall Using Double Infill Plates
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Petroleum Science And Engineering
Operation of a MEG pilot regeneration system for organic acid and alkalinity removal during MDEA to FFCI switchover
...Show More Authors

View Publication
Scopus (13)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Wed May 31 2017
Journal Name
Journal Of Engineering
Design and Implementation of Classical Sliding Mode Controller for Ball and Plate System
...Show More Authors

Ball and Plate (B&P) system is a benchmark system in the control engineering field that has been used to verify many control methods. In this paper the design of a sliding mode . controller has been investigated and verified in real-time via implementation on a real ball and plate system hardware. The mathematical model has been derived and the necessary parameters have been measured. The sliding mode controller has been designed based on the obtained mathematical model. The resulting controller has been implemented using the Arduino Mega 2560 and a ball and plate system built completely from scratch. The Arduino has been programmed by the Arduino support target for Simulink. Three test signals has been used for verification purposes

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 17 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Sonographic evaluation of masseter muscle thickness in bruxist and non-bruxist subjects
...Show More Authors

Background: Masseter muscle is a jaw closing muscle of the mandible involved in Para functional habits; which include lip and cheek chewing, fingernail biting, and teeth clenching or bruxism which can be classified as awake or sleep bruxism. Patients with sleep bruxism are three to four times more likely to experience jaw pain and limitation of movement than people who do not experience sleep bruxism. The aim of this study is to measure the thickness of the masseter muscle in bruxist subjects and compare it with non-bruxist subjects by using sonography. Materials and Method: Forty Iraqi subjects with age ranged (20-40) divided into two groups according to the presence of bruxism. Clinical examination was made and masseter muscle thickness

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Results In Chemistry
Effect of Polyeugenol coating on surface treatment of grade 23 titanium alloy by micro arc technique for dental application
...Show More Authors

Titanium alloy (Ti-6Al-4V or Gr.23) was widely used as a dental alloy. In the current study, polymerization of eugenol (PE) on Gr.23 titanium alloys was conducted by an electrochemical process before and after being treated by Micro Arc Oxidation (MAO). The formed films were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD). The corrosion behavior of Gr.23 alloy in an artificial saliva environment at a temperature range of 293–323 K has been studied and assessed by means of electrochemical polarization and impedance spectroscopy techniques. Three cases are taken into consideration; bare Gr.23, Gr.23 coated by PE, and Gr.23 coated by PE after MAO treatment. The maxi

... Show More
View Publication
Scopus (8)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Sep 06 2018
Journal Name
Al-khwarizmi Engineering Journal
Bone Defect Animal Model for Hybrid Polymer Matrix Nano Composite as Bone Substitute Biomaterials
...Show More Authors

Addition of bioactive materials such as Titanium oxide (TiO2), and incorporation of bio inert ceramic such as alumina (Al2O3), into polyetheretherketone (PEEK) has been adopted as an effective approach to improve bone-implant interfaces. In this paper, hot pressing technique has been adopted as a production method. This technique gave a homogenous distribution of the additive materials in the proposed composite biomaterial. Different compositions and compounding temperatures have been applied to all samples. Mechanical properties and animal model have been studied in all different production conditions. The results of these new TiO2/Al2O3/PEEK biocomposites with different

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
World Journal Of Dentistry
Assessment of Implant Stability Changes and Success Rate of Narrow Dental Implants
...Show More Authors

Aims: To assess the success rate and implant stability changes of narrow dental implants (NDIs) during the osseous healing period. Materials and methods: This prospective observational clinical study included 21 patients with narrow alveolar ridge of restricted mesiodistal interdental span who received NDIs. The alveolar ridge width was determined by the ridge mapping technique. Implant stability was measured using Periotest® M immediately after implant insertion then after 4 weeks, 8 weeks and 12 weeks postoperatively. The outcome variables were success rate and implant stability changes during the healing period. The statistical analysis included one-way analysis of variance (ANOVA) and Tukey\'s multiple comparisons test, values < 0.05 w

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
THe role of feeding plate in reducing some nutrirional and health problems accompaniment to cleft palate
...Show More Authors

The present study was designed to indicate the influence of the feeding plate on the nutritional and general health problems of the isolated cleft palate infants. For this study fourteen infants were taken, their ages between one day to one week, refered from cosmetic surgery and palate center to cleft lip and palate rehabilitation center in institute of technical medical / Baghdad for feeding plate purpose . Four infants put them as normal group; all those infants were subjected during (6th) month to evaluate the body weight, feeding problem and the respiratory infection. According to tables and figures this study showed a gradual improvement in nutritional problem including (feeding problem, body weight) and health problem (such as respir

... Show More
View Publication Preview PDF