Preferred Language
Articles
/
exbo0IcBVTCNdQwC3WIP
Fusion Power Density and Radiation Losses Characteristics for Tritium Fusion Reactions
...Show More Authors

A new data for Fusion power density has been obtained for T-3He and T-T fusion reactions, power density is a substantial term in the researches related to the fusion energy generation and ignition calculations of magnetic confined systems. In the current work, thermal nuclear reactivities, power densities of a fusion reactors and the ignition condition inquiry are achieved by using a new and accurate formula of cross section, the maximum values of fusion power density for T-3He and TT reaction are 1.1×107 W/m3 at T=700 KeV and 4.7×106 W/m3 at T=500 KeV respectively, While Zeff suggested to be 1.44 for the two reactions. Bremsstrahlung radiation has also been determined to reaching self- sustaining reactors, Bremsstrahlung values are 4.5×106 W/m3 at T=700 MeV and 3.8×106 W/m3 at T=500 MeV for T-3He and TT reaction respectively, ignation values then are 136 KeV for T-T and 155 KeV for T-3He. So small Zeff mean small ignition and large fusion power. Tritium Fusion Reactions have large ignition temperature than deuterium reactions.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro Comparative Assessment Of The Effect Of Gutta-Fusion Obturation On The Push Out Bond Strenght Of Three Types Of Sealers
...Show More Authors

Background: The bond strength of the root canal sealers to dentin is very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate and compare the push-out bond strength of root filled with total fill Bioceramic, AH Plus and Gutta-flow®2 sealers using GuttaFusion®obturation system versus single cone obturation technique. Materials and method: sixty of mandibular premolars teeth with straight roots were used in this study, these roots were instrumented using Reciproc system, instrumentation were done with copious irrigation of 3 mL 5.25% sodium hypochlorite solution (NaOCl) during all the steps of preparation, and smear layer will be removed with 1 ml of 17% EDTA kept in

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Apr 01 2020
Journal Name
Translational Andrology And Urology
Robotic-assisted magnetic resonance imaging ultrasound fusion results in higher significant cancer detection compared to cognitive prostate targeting in biopsy naive men
...Show More Authors

View Publication
Scopus (12)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Apr 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Empirical Formula for Neutron Yield for (α,n) Reactions from 63cu and 65cu
...Show More Authors

  The calculated neutron yields from (α, n) reactions are very important in analyzing radiation shielding of spent fuel storage, transport and safe handling. The cross sections of 63Cu (α, n) 66Ga and 65Cu (α, n) 68Ga reactions are calculated for different α-energies using different sets of programs using Matlab language. The values deduced energy is from threshold to Eα= 30 MeV and to Eα= 40 MeV for 63Cu (α, n) 66Ga and 65Cu (α, n) 68Ga respectively. The weight average cross section was then  used to calculate the neutron yields y0 (n/106α) for each reaction .The empirical formula was then suggested to calculate total neutron yield to each isotope.
 

View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Radiation doses assessment for workers on radiation measuring devices response check in RNSD laboratories
...Show More Authors

Radiation measuring devices need to periodic calibration process to examine their sensitivity and the extent of the response. This study is used to evaluate the radiation doses of the workers in the laboratories of the Directorate of Safety as a result of the use of point sources in calibrating of the devices in two ways, the first is the direct measurement by the FAG device and the others using RESRAD and RAD PRO programs. The total doses values using FAG were (2.57 μSv/y, 102.3 μSv/y and 20.75 μSv/y for TLD laboratory, Gamma spectroscopy analyses (GSA) laboratory and equipment store respectively, and the total doses that calculated using RESRAD and RAD PRO were 1.518 μSv/y, 76.65 μSv/y and 21.2 μSv/y for the above laboratories. t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Partial Level Densities for Neutron Induced Pre-equilibrium Nuclear Reactions
...Show More Authors

The state and partial level densities were calculated using the corresponding formulas that are obtained in the frame work of the exciton model with equidistant spacing model (ESM) and non-ESM (NESM). Different corrections have been considered, which are obtained from other nuclear principles or models. These corrections are Pauli Exclusion Principle, surface effect, pairing effect, back shift due to shell effect and bound state effect . They are combined together in a composite formula with the intention to reach the final formula. One-component system at energies less than 100 MeV and mass number range (50-200) is assumed in the present work. It was found that Williams, plus spin formula is the most effective approach to the composite

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Measurement and disclosure of losses resulting from terrorist operations
...Show More Authors

The aim of the research is to identify the losses resulting from the terrorist operations and then find a proposed accounting treatment for the losses resulting from the terrorist operations and to indicate their impact on disclosure in the financial statements by reviewing the international standards and local rules and the unified accounting system and not dealing with these losses, Of the financial statements and therefore adversely affect the accounting disclosure as well as the weak commitment of economic units to apply the requirements of accounting measurement and disclosure of losses of terrorist operations in a manner consistent with local and international standards to achieve the Reliability in the financial statement.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Journal Of Pakistan Association Of Dermatologists
Zinc as an essential element for normal immune reactions and as a therapeutic agent for autoimmune diseases
...Show More Authors

Scopus (1)
Scopus
Publication Date
Fri Sep 01 2023
Journal Name
Iraqi Journal Of Physics
Study the Electronic and Spectroscopic Characteristics of p-n Heterojunction Hybrid (Sn10O16/C24O6) via Density Functional Theory (DFT)
...Show More Authors

The electronic characteristics, including the density of state and bond length, in addition to the spectroscopic properties such as IR spectrum and Raman scattering, as a function of the frequency of Sn10O16, C24O6, and hybrid junction (Sn10O16/C24O6) were studied. The methodology uses DFT for all electron levels with the hybrid function B3-LYP (Becke level, 3-parameters, Lee–Yang-Parr), with 6-311G (p,d)  basis set, and Stuttgart/Dresden (SDD) basis set, using Gaussian 09 theoretical calculations. The geometrical structures were calculated by Gaussian view 05 as a supplementary program. The band gap was calculated and compared to the measured valu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
CDD Study of Charge Density Distributions and Elastic Electron Scattering Cross Sections for some Stable Nuclei: Charge Density Distributions
...Show More Authors

paper

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu May 12 2022
Journal Name
Journal Of Economics And Administrative Sciences
Nonparametric Estimator (Histogram) For Estimating Probability Density Function: Nonparametric Estimator (Histogram) For Estimating Probability Density Function
...Show More Authors

 In this paper we introduce several estimators for Binwidth of histogram estimators' .We use simulation technique to compare these estimators .In most cases, the results proved that the rule of thumb estimator is better than other estimators.

View Publication Preview PDF
Crossref