The demand for single photon sources in quantum key distribution (QKD) systems has necessitated the use of weak coherent pulses (WCPs) characterized by a Poissonian distribution. Ensuring security against eavesdropping attacks requires keeping the mean photon number (µ) small and known to legitimate partners. However, accurately determining µ poses challenges due to discrepancies between theoretical calculations and practical implementation. This paper introduces two experiments. The first experiment involves theoretical calculations of µ using several filters to generate the WCPs. The second experiment utilizes a variable attenuator to generate the WCPs, and the value of µ was estimated from the photons detected by the BB84 detection setup. The second experiment represents an accurate method for estimating the value of µ because of using single photon detectors with high timing resolution and low dark counts, in addition to using a Time-to-digital convertor with a bin size of 81 ps.
Mauddud formation is one of the most prominent formations in Northeastern Iraq due to its significant hydrocarbon reserves, making accurate geomechanical characterization essential for safe drilling operations and informed development planning. This study constructs a calibrated post-drill one dimensional mechanical earth model (1D-MEM) for selected wells, levering Techlog software to integrate rock mechanical data, image logs, multi-arm caliper measurements, conventional well logs, drilling reports, and core analyses. The methodology provides a detailed workflow for estimating geomechanical properties from log and image analysis to model calibration. Validation of the 1-D MEM performed through cross-comparison with direct me
... Show MoreThis paper analysed the effect of electronic internal auditing (EIA) based on the Control Objectives for Information and Related Technologies (COBIT) framework. Organisations must implement an up-to-date accounting information system (AIS) capable of meeting their auditing requirements. Electronic audit risk (compliance assessment, control assurance, and risk assessment) is a development by Weidenmier and Ramamoorti (2006) to improve AIS. In order to fulfil the study’s objectives, a questionnaire was prepared and distributed to a sample comprising 120 employees. The employees were financial managers, internal auditors, and workers involved in the company’s information security departments in the General Company for Electricity D
... Show MoreIn this work, a single pile is physically modeled and embedded in an upper liquefiable loose sand layer overlying a non-liquefiable dense layer. A laminar soil container is adopted to simulate the coupled static-dynamic loading pile response during earthquake motions: Ali Algharbi, Halabjah, El-Centro, and Kobe earthquakes. During seismic events with combined loading, the rotation along the pile, the lateral and vertical displacements at the pile head as well as the pore pressure ratio in loose sandy soil were assessed. According to the experimental findings, combined loading that ranged from 50 to 100% of axial load would alter the pile reaction by reducing the pile head peak ground acceleration, rotation of the pile, and lateral displacem
... Show MoreMany pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronid
... Show MoreContext: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two diff
... Show MoreMany pathophysiological processes can affect the pharmacokinetic properties of drugs in people with diabetes. The present study was deigned to evaluate the influence of diabetes mellitus (DM) on the pharmacokinetic parameters of metronidazole administered as single oral dose. Twelve healthy volunteers and twelve diabetic patients were enrolled in the present study. On day 1, a single oral dose of metronidazole 500 mg was administered orally to all participants at 9:00 am after a 10-hour fasting. Over the following 48 hours, blood samples were taken at frequent intervals and serum metronidazole concentrations were measured by a high-performance liquid chromatography method for assessment of pharmacokinetics of metronidazole. The data
... Show More