The present study aimed to investigate the possible production of Thioflavin T and the effect of NaCl concentrations and growth phases on the growth rate, doubling time and proline of C. saipanensis N. Hanagata (Scenedesmaceae, Shaerophleales). The alga was cultured in BG 11 medium and six NaCl concentrations were used in the experiments during different growth phases. The results have unveiled the presence of Triflavin T in the alga. The study results showed a growth rate decrease at all NaCl concentrations except in control treatment, while the doubling time, was recorded highest value (14 days) at the NaCl concentration of 0.08 M. The highest value of Proline (0.509 mg. Lˉ¹) was recorded at the treatment of 0.08 M of NaCl and recorded 0.3 mg. L-1 in the second phase of alga growth, and increased up to 0.695 mg. L-1in the interaction between NaCl concentrations and growth phases (0.08 M of NaCl and the second phase). The highest value of Thioflavin T (25.386 mg. Lˉ¹) was recorded at 0.005 M of NaCl and 21.937 mg. L-1 at the second phase of growth. While its concentration reaches 27. 335mg.L- in combined experiments (0.005 M of NaCl and the second phase of growth). Therefore, the results of this study unveiled the presence of Thioflavin T pigment in C. saipanensis. The NaCl concentrations and growth phases have an impact on the pigment and proline concentrations. This finding highlights the possible use of the alga to produce the Thioflavin T pigment for different purposes.
Chlorine disinfection is a globally used method to ensure the safety of drinking water. However, it has not always been successful against viruses and, therefore, it is important to find new methods to disinfect water. Seventeen different coliphages were isolated from the treated municipal wastewater. These coliphages and MS2 were treated with different dosages of chlorine in drinking water, and a combined chlorine/ultraviolet irradiation treatment for the chlorine-resistant coliphages. Chlorine disinfection with 0.3–0.5 mg/L total chlorine (free Cl-dosage 0.12–0.21 mg/L) for 10 min achieved 2.5–5.7 Log10-reductions for 11 sensitive coliphages. The six most resistant coliphages showed no reduction with these chlorine concentra
... Show MoreThe advancements in horizontal drilling combined with hydraulic fracturing have been historically proven as the most viable technologies in the exploitation of unconventional resources (e.g., shale and tight gas reservoirs). However, the number of fractures, well timing, and arrangement pattern can have a significant impact on the project economy. Therefore, such design and operating parameters need to be efficiently optimized for obtaining the best production performance from unconventional gas reservoirs. In this study, the process of selecting the optimal number of fractures was conducted on a section of a tight gas reservoir model (based on data from the Whicher Range (WR) tight gas field in Western Australia). Then, the optimal number
... Show MorePesticide poisoning is a serious global public health issue and is responsible for a sizable number of annual fatalities. This study was designed to examine the potentially harmful effects of adult rats being exposed to imidacloprid (IMD) as a nanoparticle by determining the chronic effect of inhalation of (5,10 and 20) mg/kg/b.w. of nano-imidacloprid for a duration of 60 days. The most important biochemical parameters of the serum liver function parameters were aspartate aminotransferase (AST), alanine aminotransferase (ALT), and alkaline phosphatase ALP, kidney function [blood urea, creatinine, and urea], and oxidative stress parameters (MDA, GSH, and CAT) in all treated groups when
In cooling water systems, cooling towers play a critical role in removing heat from the water. Cooling water systems are commonly used in industry to dispose the waste heat. An upward spray cooling water systems was especially designed and investigated in this work. The effect of two nanofluids (Al2O3/ water, black carbon /water) on velocity and temperature distributions along reverse spray cooling tower at various concentrations (0.02, 0.08, 0.1, 0.15, and 0.2 wt.%) were investigated, beside the effect of the inlet water temperature (35 ,40, and 45 ͦ C) and water to air flow ratio (L/G) of 0.5, 0.75, and 1. The best thermal performance was found when the working solution contained 0.1 wt.% for each of Al2
... Show Moreم.د. فاطمة حميد ،أ.م.د وفاء صباح محمد الخفاجي, International Journal of Psychosocial Rehabilitation,, 2020 - Cited by 1
In this study, the water treatment plants located on the Tigris River within Baghdad city were subjected to qualitative and quantitative assessments. Based on location, the plants from upstream to downstream are Al-Karkh, East Tigris, Al-Karamah, Al-Wathbah, Al-Wehdah, Al-Kadiseyah, Al-Dora, and Al-Rashid. Data from 2009 to 2020 on the turbidity, total dissolved solids, Alkalinity, hardness, chloride, calcium, and temperature were used in the qualitative assessment while data on the treated water production and population served were used in the quantitative assessment. The above Data was acquired from the Municipality of Baghdad. The turbidity was mainly used as a fair gauge to assess the performance of the water treatment plants in Baghda
... Show MoreThis paper aims to improve the voltage profile using the Static Synchronous Compensator (STATCOM) in the power system in the Kurdistan Region for all weak buses. Power System Simulation studied it for Engineers (PSS\E) software version 33.0 to apply the Newton-Raphson (NR) method. All bus voltages were recorded and compared with the Kurdistan region grid index (0.95≤V ≤1.05), simulating the power system and finding the optimal size and suitable location of Static Synchronous Compensator (STATCOM)for bus voltage improvement at the weakest buses. It shows that Soran and New Koya substations are the best placement for adding STATCOM with the sizes 20 MVAR and 40 MVAR. After adding STATCOM with the sizes [20MVAR and 40MV
... Show More