Background: Arterial stiffness is related with atherosclerosis and cardiovascular disease events. Patients with atherosclerotic disease show to have larger diameters, reduced arterial compliance and lower flow velocities. Aim of study : To compare between patients of two age groups with concomitant diseases diabetes and hypertension in regard to intima media thickness and blood flow characteristics in order to estimate the blood perfusion to the brain via the common and internal carotid arteries. Subject and Methods : 40 patients with (diabetic and hypertension) diseases were enrolled , they were classified according to age. Color Doppler and B mode ultrasound was used to determine lumen Diameter (D), Intima – media thickness (IMT), end diastolic velocity (EDV), peak systolic velocity (PSV), Resistive Index (RI), Pulsatility Index (PI), and the flow rate indices were calibrated and calculated . Results:- Results show that the change in the lumen diameter between the old patients group and the younger group were (2.02%) with insignificant (p value >0.05), and the difference in the in intima-media (IMT) thickness between the two age groups (35- 55) and (56-75) are (33.8%) with significant (p value <0.05). The change difference in peak systolic velocity was (-13.29% ) with insignificant (p value >0.05), while the difference in the (EDV) between both age groups was (-38.02%), with significant p value <0.05. Pressure gradient and flow rate have given insignificant difference between both age groups. Conclusion: The intima media is significantly thicker for the old age group than in the younger group. The increased thickness of intima media did not influence the lumen diameter significantly. A clear change in PSV, EDV, RI, and PI was observed which have influenced blood perfusion to the brain.
Glay pots experiments were carried out in the botanical garden of Biology Department/ College of Education for Pure Science Ibn AL-Haitham / Baghdad University for the growing season 2014-2015 , to evaluate the effect of foliar spraying of hydrogen peroxide ( H2O2) and glutamic acid and their interaction on some growth parameters and yield components of black cumin plant . The experiment included the following factors :- 1- Four concentrations of hydrogen peroxide (0 , 5 , 10 , 20 ) mM.L-1 . 2- Three concentrations of glutamic acid ( 0 , 50 , 100 ) mg.L-1 . The experiment was designed according to completely randomized design (CRD) with three replications , Results revealed that
... Show MoreA new simple and sensitive spectrophotometric method for the determination of trace amount of Cu(II) in the ethanol solution have been developed. The method is based on the complexation of Cu(II) with ethyl cyano(2-methyl carboxylate phenyl azo acetate) (ECA) in basic medium of sodium hydroxide givining maximum absorbance at (λmax = 521 nm). Beer's law is obeyed over the concentration range (5-50) (μg / ml) with molar absorptivity of (3.1773 × 102 L mol-1 cm-1) and correlation coefficient (0.9989). The optimum conditions for the determination of Cu(II)-complex and have been studied and applied to determine Cu(II) in synthetic water sample using simple and standard addition methods.
The present study is to investigate the possibility of using wastes in the form of scrap iron (ZVI) and/ or aluminum ZVAI for the detention and immobilization of the chromium ions in simulated wastewater. Different batch equilibrium parameters such as contact time (0-250) min, sorbent dose (2-8 g ZVI/100 mL and 0.2-1 g ZVAI/100 mL), initial pH (3-6), initial pollutant concentration of 50 mg/L, and speed of agitation (0-250) rpm were investigated. Maximum contaminant removal efficiency corresponding to (96 %) at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed were obtained.
The best isotherm model for the batch single Cr(III) uptake by ZVI
... Show MoreIn this study, the flexural performance of a new composite beam–slab system filled with concrete material was investigated, where this system was mainly prepared from lightweight cold-formed steel sections of a beam and a deck slab for carrying heavy floor loads as another concept of a conventional composite system with a lower cost impact. For this purpose, seven samples of a profile steel sheet–dry board deck slab (PSSDB/PDS) carried by a steel cold-formed C-purlins beam (CB) were prepared and named “composite CBPDS specimen”, which were tested under a static bending load. Specifically, the effects of the profile steel sheet (PSS) direction (parallel or perpendicular to the span of the specimen) using different C-purlins c
... Show MoreThe article presents the results of studying the conchological variability of the terrestrial mollusk Chondrulopsina fedtschenkoi (Ancey, 1886), known to occur in three regions of the Zaravshan Range (Central Asia): the Urgutsay Gorge, the vicinity of the Gissarak Reservoir and the Ingichka-Irmak Gorge. Conchological variability was determined based on statistical analysis. The climate of the three regions is different, and environmental factors have led to changes in the mollusk shell. The shells have changed in response to environmental factors, these are their adaptive traits for survival; the variability of conchological features is also reflected in the color of the shell, and the intensive development of the color of the shell in m
... Show MoreThe objective of this paper is to improve the general quality of infrared images by proposes an algorithm relying upon strategy for infrared images (IR) enhancement. This algorithm was based on two methods: adaptive histogram equalization (AHE) and Contrast Limited Adaptive Histogram Equalization (CLAHE). The contribution of this paper is on how well contrast enhancement improvement procedures proposed for infrared images, and to propose a strategy that may be most appropriate for consolidation into commercial infrared imaging applications.
The database for this paper consists of night vision infrared images were taken by Zenmuse camera (FLIR Systems, Inc) attached on MATRIC100 drone in Karbala city. The experimental tests showed sign
Background: Due to the variations in tooth anatomy and size among different populations, this study aimed to compare the mesiodistal width of primary second molars in Iraqi children with the mesiodistal width of stainless-steel crowns from different companies. Materials and Methods: This cross-sectional study was conducted on 220 intact maxillary and mandibular primary second molars selected from boys and girls’ Iraqi children aged 8-9 years collected from different primary schools in Baghdad city. The mesiodistal dimensions of the selected teeth and the available maxillary and mandibular stainless-steel crowns from three different companies were measured by using a 3-D scanner, and then the whole measurements were calculated usin
... Show More