Background: Fertility plays great role in animal reproduction since high quality semen improves sheep industry reproduction. The current worldwide data revealed the closely related of CNP to reproductive function of rams. Aims: Evaluation the effect of CNP on cooled sperms using the traditional and molecular assays. Methods: Totally, 20 testicular samples were collected, processed to obtain the semen samples and divided into two parts; one treated with the suitable dose of CNP and the otherserved as a control. Sperm samples of both groups were cooled for 3 days and tested at 0 0h, 24h, 48h and 72h. Results: The findings revealed that the suitable dose of CNP-treated sperms was 0.0110-13. Values individual motility, live sperms and sperm concentration were reduced significantly in CNP-24h, CNP-48h and CNP-72h when compared to control; however, abnormal sperms were increased in both control and CNP groups at 24h, 48h and 72h when compared to values of 0h. Concerning turbidmetric analysis, significant reduction in values of lag time was observed in CNP when compared to control at all times of cooling intervals. In both CNP and control groups, motility index was decreased at 24h, 48h and 72h when compared to 0h. For velocity, significant increases were showed in CNP compared with control at all cooling intervals. However, values of both groups were increased significantly at 24h, 48h and 72h times when compared to 0h. FRMS of CNP was elevated at 0h and decreased at 24h, 48h and 72h when compared to control. Expression of hNPR-B gene was reduced gradually in sperms of CNP and control groups at times of cooling intervals. Conclusion: For our knowledge, this first Iraqi study targets the effect of CNP on epididymal sperms of rams. However, changes occur after excessive CNP exposure remains unclear, and toxicological profile of CNP required furthermore supplements.
Values are penetrating or interfering in the lives of individuals and groups and are connected to them in the sense of life itself, because they are closely linked to the motives of behavior, hopes and goals, and can be said that values are everything. The concept of values is one of the concepts that have received the attention of researchers from different disciplines. This has resulted in a kind of confusion and variation in use from one specialization to the other, and uses multiple uses within one specialization. Therefore, there is no uniform definition of values because they relate to individuals. Individuals differ in many things, such as perception,
... Show MoreAbstract : Silicone elastomer is widely used as the material of choice for fabricating maxillofacial prosthesis. However, silicone properties are far from ideal; low tear strength, low tensile strength and insufficient elasticity are the most undesirable properties. The purpose of this study was to evaluate the effect of addition of nano SiO2filler on tear strength, tensile strength, elongation at break, hardness and color of Cosmesil M-511 HTV maxillofacial silicone elastomer. Nano SiO2was added to the silicone base in concentrations of 4%, 5% and 6% by weight. Silicone with 0% nano filler served as a control. Tear test was done according to ISO 34-1. Tensile and elongation test was done according to ISO 37. Shore A hardness test was done
... Show MoreThe aim of this study is to get practical evidence from the Egyptian business environment The Impact of Audit Committees Effectiveness and External Audit Quality on Timeliness of annual Financial Report. Design and methodology: The study based on the content analysis technique to examine the annual reports of a sample of (30) companies listed on the Egyptian Stock Exchange (EGX100) during the period (2016-2019) with a total of (120) respondents. To test the research hypotheses, the results of the study indicate that there is a negative significant impact of audit committees on timeliness of annual financial report. Moreover, while there is a negative impact on the quality of the external audit on the timing of issuing the annual
... Show Moreloaded reinforced concrete circular short columns. An experimental investigation into the behavior
of 24 short reinforced concrete columns with and without steel fibers was carried out. The columns
had a circular section (200 mm diameter and 900 mm long). Test variables include concrete
strength, spacing of spiral reinforcement, and inclusion of steel fibers. The axial stress and axial
strains were obtained and used to evaluate the effects of the presence of steel fibers. It was found
that the addition of steel fibers slightly improves the load carrying capacity of the tested columns
whereas it significantly enhances the ductility of these specimens. Test results also indicated that for
the same confinement parameter
In this paper a thin films of selenium was prepare on substrates of n-Si by evaporation in a vacuum technique with thickness about 0.5μm. And then an annealing process was done on samples at two temperature (100 and 200) C ° in a vacuum furnace (10-3 torr).
Some structural, optical and mechanical properties of prepared thin films were measured. Results showed that the prepared film was the crystallization, optical transmittance and micro hardness of the prepared thin films increased significantly after annealing.
Heavy metal ion removal from industrial wastewater treatment systems is still difficult because it contains organic contaminants. In this study, functional composite hydrogels with photo Fenton reaction activity were used to decompose organic contaminants. Fe3O4 Nanoparticle, chitosan (CS), and other materials make up the hydrogel. There are different factors that affected Photo-Fenton activity including (pH, H2O2 conc., temp., and exposure period). Atomic force microscopy was used to examine the morphology of the composite and its average diameter (AFM). After 60 minutes of exposure to UV radiation, CS/ Fe3O4 hydrogel composite had degraded methylene blue (M.B.)
... Show MoreBackground: Improved glucose level control with insulin injections have allowed for the diabetic population to live longer and healthier lives. Unfortunately diabetes remains a worldwide epidemic disease with multiple health implications. Specifically, its effects upon fracture healing are compromised in diabetics with as high as 87% recovery delay relative to “healthy†counterparts. Current medical treatments for bone injuries have been largely focused on replacing the lost bone with allogenic or autogenous bone grafts, beta-tricalcium phosphate (β -TCP), a ceramic alloplast, has interconnected system of micropores, has been widely used as a biologically safe osteoconductive bone substitute. The aim of this study was histol
... Show MoreBackground: The microhardness of a composite resin is a vital parameter that is used to determine its clinical behavior. Measuring the microhardness of a composite resin has been used as an indirect method to assess its degree of conversion and extent of polymerization. The purpose of this in vitro study was to evaluate the effect of three curing distances (0, 2, and 4 mm) on the microhardness of the top and bottom surfaces of three types of flowable bulk-fill composite resins (smart dentin replacement, Opus bulk fill flow, and Tetric N). Material and method: Sixty-three specimens from the three types of composite resins (n=21) were fabricated using Teflon mold with a 4mm depth and a 5 mm internal diameter and cured for 20 seconds. For e
... Show MoreThis study aimed to identify the effect of resistance training on the biomechanics and accuracy of serve receiving skills in volleyball. The research community was composed of 26 young volleyball players of Baghdad volleyball clubs. A total of 4 players were selected for the preliminary experiment, while 14 participants were recruited as the main sample for the study. In the present study, a set of resistance exercises were designed by the researchers for the volleyball players of the sample. Exercises were performed by the sample participants during the course of study. The biomechanical variables considered in the present study were: Preparation moment (shoulder joint angle, hip angle, knee joint angle), moment of pr
... Show More