Background: Fertility plays great role in animal reproduction since high quality semen improves sheep industry reproduction. The current worldwide data revealed the closely related of CNP to reproductive function of rams. Aims: Evaluation the effect of CNP on cooled sperms using the traditional and molecular assays. Methods: Totally, 20 testicular samples were collected, processed to obtain the semen samples and divided into two parts; one treated with the suitable dose of CNP and the otherserved as a control. Sperm samples of both groups were cooled for 3 days and tested at 0 0h, 24h, 48h and 72h. Results: The findings revealed that the suitable dose of CNP-treated sperms was 0.0110-13. Values individual motility, live sperms and sperm concentration were reduced significantly in CNP-24h, CNP-48h and CNP-72h when compared to control; however, abnormal sperms were increased in both control and CNP groups at 24h, 48h and 72h when compared to values of 0h. Concerning turbidmetric analysis, significant reduction in values of lag time was observed in CNP when compared to control at all times of cooling intervals. In both CNP and control groups, motility index was decreased at 24h, 48h and 72h when compared to 0h. For velocity, significant increases were showed in CNP compared with control at all cooling intervals. However, values of both groups were increased significantly at 24h, 48h and 72h times when compared to 0h. FRMS of CNP was elevated at 0h and decreased at 24h, 48h and 72h when compared to control. Expression of hNPR-B gene was reduced gradually in sperms of CNP and control groups at times of cooling intervals. Conclusion: For our knowledge, this first Iraqi study targets the effect of CNP on epididymal sperms of rams. However, changes occur after excessive CNP exposure remains unclear, and toxicological profile of CNP required furthermore supplements.
The current study was to examine the reliability and effectiveness of using most abundant, inexpensive waste in the form of scrap raw zero valent aluminum ZVAI and zero valent iron ZVI for the capture, retard, and removal of one of the most serious and hazardous heavy metals cadmium dissolved in water. Batch tests were conducted to examine contact time (0-250) min, sorbent dose (0.25-1 g ZVAI/100 mL and 2-8 g ZVI/100 mL), initial pH (3-6), pollutant concentration of 50mg/L initially, and speed of agitation (0-250) rpm . Maximum contaminant removal efficiency corresponding to (90 %) for cadmium at 250 min contact time, 1g ZVAI/ 6g ZVI sorbent mass ratio, pH 5.5, pollutant concentration of 50 mg/L initially, and 250 rpm agitation speed wer
... Show MoreA new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n
... Show MoreMixed ligands reaction of [2-[(3-hydroxyphenyl)diazinyl]-1,2-benzothiazol-3(2H)-one-1,1-dioxide] (H2L, primary ligand) and bipyridyl (secondary ligand) with salts of Cr(III), Mn(II), Fe(III), Co(II) and Ni(II) was performed. A series of air-stable complexes with distinctive octahedral moieties was created by equal molar ratio (1:1:1). The formation of these compounds was verified using detecting analysis techniques incorporating mass spectra, which validated the achieved geometries. Fourier transform infrared (FTIR) analysis demonstrated how the ligands (H2L and bipyridyl) are chelated as tridentate (ONO) and bidentate (NN) groups, respectively and the coordination with the metal ions. Thermal decomposition studies using pyrolysis (
... Show MoreA simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, wi
... Show MoreUntil today, one of the leading predominant infections is Urinary tract infection (UTI). It exerts a huge burden on health systems worldwide each year. Treating UTIs empirically with antimicrobials improves morbidity rates. This study aims to assess the prevalence of UTI-associated bacteria in adult patients and to determine their antibiotic susceptibility profile. A retrospective study was conducted for adult outpatients who visited Al-Diwaniya tertiary hospitals from January 2020 till February 2022 to review their medical and lab records in addition to sociodemographic data. A total of 256 patients’ records were included of which 204 (79.7%) belong to females and 52 (20.3%) were males with an average age of 39.22±17.10 years. T
... Show MoreA simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl
... Show MoreOne common heavy metal that is extremely harmful to the kidneys, reproductive system, and nervous system of humans is lead (Pb). This study aimed to investigate the effectiveness of a novel nanocomposite adsorbent, synthesised from polypyrrole, zinc oxide, and nickel (PPy/ZnO-NiO), in eliminating Pb(II) ions from a waterbased solution. This adsorbent offers excellent metal selectivity, environmental stability, ease of manufacture, and reusability. Several techniques, namely XRD, FTIR, TGA, SEM, TEM, EDX, and BET, were employed to characterize the synthesised nanocomposite adsorbent. The study examined the impact of multiple factors influencing the adsorption process, including pH, temperature, contact period, metal ion concentration, and ad
... Show MorePolyvinyl chloride (PVC) ultrafiltration membranes were efficiently fabricated using a (0.1–0.5 wt.%) Ag 2 O@CuO heterojunction photocatalyst to form a PVC/Ag 2 O@CuO photocatalytic membrane (PM) stimulated by UV light. The PVC/Ag 2 O@CuO PM fabricated using the phase inversion process resulted in significant improvement in internal morphology, porosity, pure water flux, and separation efficacy of the doped membranes. The efficacy of the PVC/Ag 2