This study was aimed to determine bone formation markers (OST and BALP) and lysyl oxidase in diabetes and non-diabetes Iraqi acromegaly patients in addition to find the relationship among these parameters. The present study conducted 60 acromegalic patients (30 diabetes & 30 non diabetes) attending National Diabetes Center / AL-Mustansiriya University/Baghdad, and 30 healthy individuals as a control group aged (35-60) years. All patients were administrated Sandostatin drug, and they were diagnosed by physician in the hospital.FBG, GH, IGF-1, OST, BALP, and LOX were determined in all groups. The results showed a highly significant rise in all parameters (GH, IGF-1, FBG, OST, BALP, and LOX values in serum of all patients when compared with normal individuals. There were some positive highly significant correlations for lysyl oxidase with osteocalcin and a positive significant with BALP in acromegalic patients. We concluded that lysyl oxidase may be a novel biomarkers in endocrine diseases like acromegaly.
Background: Dilated cardiomyopathy (DCM) is a well-recognized cause of cardiovascular morbidity and mortality.Objectives: To evaluate the prognostic implications of the restrictive left ventricular filling pattern (RFP) in dilated cardiomyopathy.Methods: Patients with DCM admitted to Ibn AL-Bitar Hospital for Cardiac Surgery, Baghdad-Iraq, from May 2006 to August 2008, underwent a full clinical evaluation and Doppler echocardiography study. Patients were classified into three groups: Group I had persistent restrictive filling pattern; Group II had reversible restrictive filling pattern; and Group III had nonrestrictive filling pattern. Results: The current study was conducted on a total number of 80 patients with DCM, fifty (62.5 %) were
... Show MoreBackground: Chronic kidney disease is a condition that results from an indefinite change in the structure and function of the kidneys. A slow, steady progression characterizes it and is irreversible. Objectives: This study aims to evaluate the findings of certain biochemical and hematological tests in samples from Iraqi CKD patients. Methods: This study included 90 subjects, where 70 patients with chronic kidney disease and 20 healthy individuals. Blood samples were collected from the patients during their visits to Ghazi Al-Hariri Surgical Specialties' Hospital- Medical City, Baghdad, Iraq. Age, sex and body mass index were assessed for each participant followed by renal function tests [serum blood urea, creatinine, uric acid a
... Show MoreBackground: Rhinosinusitis is an inflammatory disorder that refers to inflammation of the nose and paranasal sinuses. Recent studies show that serum IL-33, periostin, ARGE and sST2 had the role in the pathogenesis of chronic rhinosinusitis as an easy, non-invasive and readily available (biomarker) for diagnosis of chronic rhinosinusitis. We tested for correlations of IL-33, periostin, ARGE and sST2 between acute and chronic rhinosinusitis in compare to healthy people. This study aimed to Measure serum levels of periostin, IL-33, sST2, and ARGE biomarkers in patients ARS and CRS. Materials and Methods: We collected serum of 30 patients with acute rhinosinusitis, 30 with chronic rhinosinusitis, and 30 controls to examine serum levels of IL-3
... Show MoreA sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and
... Show MoreBackground: We aimed to investigate the accuracy of salivary matrix metalloproteinases (MMP)-8 and -9, and tissue inhibitor of metalloproteinase (TIMP)-1 in diagnosing periodontitis and in distinguishing periodontitis stages (S)1 to S3. Methods: This study was a case–control study that included patients with periodontitis S1 to S3 and subjects with healthy periodontia (controls). Saliva was collected, and then, clinical parameters were recorded, including plaque index, bleeding on probing, probing pocket depth, and clinical attachment level. Diagnosis was confirmed by assessing the alveolar bone level using radiography. Salivary biomarkers were assayed using an enzyme-linked immunosorbent assay. Results: A total of 45 patients (15
... Show MoreThe current work aims to evaluate the association between genetic mutations in thymidylate synthetase (
This research aims to study the radiation concentration distribution of the old District of Najaf (Iraq), where 15 samples were taken from featured sites in the District, which represents archaeological, religious, and heritage sites. Track detector CR-39 was used to calculate the concentration of three different soil weights for each sample site after being exposed for a month. Geographical information systems (GIS) were used to distribute the radioactive concentration on the sites of the samples, where two interpolation methods, namely the inverse distance weight method (IDW) and the triangle irregular network method (NIT), to study the distribution of the radioactivity concentration. The study showed that the western part of the district
... Show MoreA direct, sensitive and efficient spectrophotometric method for the determination of nitrofurantoin
drug (NIT) in pure as well as in dosage form (capsules) was described. The suggested method was
based on reduction NIT drug using Zn/HCl and then coupling with 3-methyl-2-benzothiazolinone
hydrazone hydrochloride (MBTH) in the presence of ammonium ceric sulfate. Spectrophotometric
measurement was established by recording the absorbance of the green colored product at 610 nm.
Using the optimized reaction conditions, beer’s law was obeyed in the range of 0.5-30 μg/mL, with
good correlation coefficient of 0.9998 and limits of detection and quantitation of 0.163 and 0.544
μg/mL, respectively. The accuracy and
In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m
... Show More