Astronomers have known since the invention of the telescope that atmospheric turbulence affects celestial images. So, in order to compensate for the atmospheric aberrations of the observed wavefront, an Adaptive Optics (AO) system has been introduced. The AO can be arranged into two systems: closedloop and open-loop systems. The aim of this paper is to model and compare the performance of both AO loop systems by using one of the most recent Adaptive Optics simulation tools, the Objected-Oriented Matlab Adaptive Optics (OOMAO). Then assess the performance of closed and open loop systems by their capabilities to compensate for wavefront aberrations and improve image quality, also their effect by the observed optical bands (near-infrared band and visible band), the shape of the telescope aperture (circular and hexagonal) and the atmospheric seeing conditions. The results showed that open-loop systems perform better than closed-loop systems at good seeing and vice versa. Also showed that closed-loop provides stability in the correction process over time, while the open-loop is a faster phase compensator
Groundwater modelling is particularly challenging in arid regions where limited water recharge is available. A fault zone will add a significant challenge to the modelling process. The Western Desert in Iraq has been chosen to implement the modelling concept and calculate the model sensitivity to the changes in aquifer hydraulic properties and calibration by researching 102 observations and irrigation wells. MODFLOW-NWT, which is a Newtonian formulation for MODFLOW-2005 approaches, have been used in this study. Further, the simulation run has been implemented using the Upstream-Weighting package (UPW) to treat the dry cells. The results show sensitivity to the change of the Kx value for the major groundwater discharge flow. Only abo
... Show MoreResource estimation is an essential part of reservoir evaluation and development planning which highly affects the decision-making process. The available conventional logs for 30 wells in Nasiriyah oilfield were used in this study to model the petrophysical properties of the reservoir and produce a 3D static geological reservoir model that mimics petrophysical properties distribution to estimate the stock tank oil originally in place (STOOIP) for Mishrif reservoir by volumetric method. Computer processed porosity and water saturation and a structural 2D map were utilized to construct the model which was discretized by 537840 grid blocks. These properties were distributed in 3D Space using sequential Gaussian simulation and the variation in
... Show MoreIn this study, we design narrow band pass filter for window (3_5) ?m dependent on the needle optimization method , and a comparison with global designs published -Also, the effect of change parameter design on the optical performance of filter was studded and being able to overcome the difficulties of the design.In this study, the adoption of homogeneous optical properties materials as thin film depositing on a substrate of germanium at wavelength design (? = 4 ?m). For design this kind of filters we used advanced computer program (Matlab )to build a model design dependent both matrix characteristic and Needle technique. In this paper we refer to the type of Mert function , which is used for correct optical performance acces
... Show MorePick and place system is one of the significant employments of modern robots utilized in industrial environments. The objective of this research is to make a comparison of time sequences by combining multiple axes of sequences. A pick-place system implemented with pneumatic linear double-acting cylinders to applicator in automated systems processes for manufacturing. The challenge of 3-axes movement control was achieved using the PLC (Programmable Logic Controller) controller such that the merging between two or three axes was achieved according to the selected sequence of the program. The outcomes show the contrasted sequences and the reference in a constant velocity. The main variable parameter is the number of steps for each sequ
... Show MoreRecently, dental implants have experienced increasing demand as one of the most effective, permanent and stable ways for replacing missing teeth. However, peri-implant diseases that are multispecies plaque-based infections may ultimately lead to implant failure (i.e., late peri-implantitis). Therefore, the present study aims to detect the microbial diversity of subgingival plaque in peri-implantitis cases (N = 30) by comparing with healthy implants (N = 34) using culture-based identification methods, including VITEK 2 system. An increase in microbial diversity (29 species along with 1 and 7 isolates, which were classified as a genus and unidentified species, respectively) were observed in subgingival sites of diseased implants dominated by
... Show MoreNinety eight mobile samples, (54) galaxy phone and (44) I phone, were swabbed for bacterial culture determination by culturing on MacConky agar , Blood agar , Mannitol salt agar , Muller Hinton agar .Staphylococcuswas the highest frequent isolated bacteria from Galaxy phone (33%) and I phone (37%). This study revealed that galaxy phone appears less contaminated with bacteria, the ratio of non-contaminated devices is (44%) when compared with I phone (9%). Sensitivity test showed that Ogmintin have the lowest effect on Staphylococcusisolated from both type of devices while cefitriaxone have the highest effect. DNA of isolate from galaxy 31 that exhibit highest resistance against antibiotics was extracted and 16S rRNA gene was polymerized by P
... Show MoreThis study focused on two areas in AL-Najaf city, AL-Ruhbah and Al-Haydariyah regions because of the importance and widespread use of groundwater in these areas. The two areas were compared quantitatively and qualitatively. For the quantitative approach, the GMS software was used in conjunction with the GIS software to simulate the groundwater flow behavior. The solid model for both areas was created, the geological formation was determined, and the hydraulic properties were identified using GMS software. To test the quantity of groundwater in both areas, the wells have been redistributed to a distance of 2000 m between them, and a period of 1000 days was chosen. When a discharge of 10 l/s and operation times of 4, 8, an
... Show More