Preferred Language
Articles
/
e3jm7KABuRolNscLzvWS
Effect of Diaphragms on Shear Lag in Steel Box Girders
...Show More Authors

This paper reports a study of the effects of steel plate diaphragms on shear lag in steel box girders within the elastic range of material property and without including the effect of plate buckling. STAAD.Pro program had been utilized to evaluate and determine top flange stress distribution and the actual effective flanges width in steel box girders with or without diaphragms. Shell elements had been used to model the flanges, webs, and diaphragms. Different numbers, thickness and types for the plate diaphragms have been used to determine their effects on the shear lag in the flange. Using diaphragms had affected slightly shear lag. The diaphragms number affected obviously the shear lag in the top flange, especially the magnitude of maximum top flange longitudinal stresses.

Publication Date
Thu Oct 01 2015
Journal Name
Journal Of Engineering
Wear Rate and Hardness of Boride Low Carbon Steel
...Show More Authors

There are no single materials which can withstand all the extreme operating conditions in modern technology.  Protection of the metals from hostile environments has therefore become a technical and economic necessity.  

In this work, for enhancing their wear-resistance, boride layers were deposited on the surface of low carbon steel by a pack cementation method at 850 °C for (2, 4, and 6) h using vacuum furnace. The boronizing process was achieved using different concentration of boron source (20, 25, and 30) % wt. into coating mixture to optimize the best conditions which ensure the higher properties with lower time. The coating was characteristic by X ray diffraction (XRD), and it is confirmed t

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 02 2017
Journal Name
Al-khwarizmi Engineering Journal
Improvement of Microhardness and Corrosion Resistance of Stainless Steel by Nanocomposite Coating
...Show More Authors

Abstract

 

Stainless steel (AISI 304) has good electrical and thermal conductivities, good corrosion resistance at ambient temperature, apart from these it is cheap and abundantly available; but has good mechanical properties such as hardness. To improve the  hardness and corrosion resistance of stainless steel its surface can be modified by developing nanocomposite coatings applied on its surface. The main objective of this paper is to study effect of electroco-deposition method on microhardness and corrosion resistance of stainless steel, and to analyze effect of nanoparticles (Al2O3, ZrO2 , and SiC)  on properties of composite coatings. I

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Engineering
Dry Sliding Wear Behavior of EN25 Steel Treated by Different Quenching Media
...Show More Authors

The present investigation aims to study the effect of heat treatment by quenching in different quenching media (salt water, water and oil) following by tempering on wear resistance of EN25 steel. EN25 steel is an alloy of medium carbon low alloy steel which is used for many applications requiring high tensile strength and wear resistance such as connecting rods, adapters and in power sectors extensively. The specimens are machined to 20 mm in length and 10 mm in diameter. This study is done by two stages: The first stage is done by austenitizing EN25 steel to 850  for 1 hr by quenching the specimens in three different quenching media and then tempered at 300   in air. While the second stage is performed by wear

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
World Journal Of Pharmaceutical Research
TERATOGENIC EFFECT OF METHOTREXATE ON HISTOGENESIS OF TESTIS IN NEWBORN RAT
...Show More Authors

Background: Methotrexate (MTX) was one of the first drugs synthesized for a specific chemotherapeutic purpose used to inhibit folic acid (FA) for the treatment of acute lymphoblastic leukemia in children. Its history is closely related to the discovery and characterization of folic acid. It is used clinically in medicine to treat a range of cancerous and noncancerous conditions. MTX is currently used in gynecology to treat disorders arising from trophoblastic tissue, namely, ectopic pregnancy. MTX, the most frequently used diseasemodifying anti-rheumatic drug (DMARD), suppresses disease activity and reduces joint damage. The aim of study: It is designed to demonstrate the effect of MTX (7.5 mg/wk.) on the histogenesis of gonad (testis) of n

... Show More
Publication Date
Sat Oct 03 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Shear bond strength of endodontic sealers to dentin with and without smear layer and gutta percha (An in vitro study)
...Show More Authors

Background: The bond strength of root canal sealers to dentin and gutta-percha seems to be an important property for maintaining the stability of root canal filling, which potentially influences both leakage and root strength. The objective of this, in vitro, study was to evaluate the shear bond strength of three different endodontic sealers (Gutta-Flow, AH Plus, Apexit Plus) to dentin, in the presence and absence of the smear layer and gutta percha. Material and Methods: After slicing off the occlusal 2mm of 60 extracted human maxillary premolar teeth, the exposed dentin served as the tested surfaces; the teeth were fixed with cold cure acrylic, and were divided into two groups according to the smear layer presence, group A without smear

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 31 2016
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Buckling Resistance of Aluminized Long Columns of Stainless Steel AISI 303
...Show More Authors

This paper has investigated experimentally the dynamic buckling behavior of AISI 303 stainless steel Aluminized and as received long columns. These columns, hot-dip aluminized and as received, are tested under dynamic buckling, 22 specimens, without aluminizing (type 1), and 50 specimens, with hot-dip aluminizing at different aluminizing conditions of dipping temperature and dipping time (type 2), are tested under dynamic compression loading and under dynamic combined loading (compression and bending) by using a rotating buckling test machine. The experimental results are compared with Perry Robertson interaction formula that used for long columns. Greenhill formula is used to get a mathematical model that descripts the buckling behavior

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of Shear Bond Strength of Sapphire Bracket Bonded to Zirconium Surface after Using Different Surface Conditioning Methods (In Vitro Study)
...Show More Authors

Background: The present study was carried out to compare shear bond strength of sapphire bracket bonded to zirconium surface after using different methods of surface conditioning and assessment of the adhesive remnant index. Materials and methods: The sample composed of 40 zirconium specimens divided into four groups; the first group was the control, the second group was conditioned by sandblast with aluminum oxide particle 50 μm, the third and fourth group was treated by (Nd: YAG) laser (1064nm)(0.888 Watt for 5 seconds) for the 1st laser group and (0.444 Watt for 10 seconds) for the 2nd laser group. All samples were coated by z-prime plus primer. A central incisor sapphire bracket was bonded to all samples with light cure adhesive res

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Oct 31 2025
Journal Name
International Journal Of Corrosion And Scale Inhibition
Sustainable corrosion inhibition using Aloe vera extract and its nanocomposites for carbon steel (CS1137) in seawater
...Show More Authors

Two nanocomposite corrosion inhibitors were synthesized from Aloe vera extract: one incorporating sodium thiosulfate and the other silver nitrate. Both nanocomposites were subjected to structural characterization using atomic force microscopy (AFM), which revealed distinct morphological features. The sodium thiosulfate-based nanocomposite exhibited uniform and well-dispersed nanoparticles with an average size of 47.51 nm, suggesting a stable and homogeneous distribution. In contrast, the silver nitrate-based nanocomposite displayed slightly larger particles with an average diameter of 58.34 nm, indicating a tendency toward moderate aggregation. The corrosion inhibition performance of these nanocomposites for carbon steel (CS1137) was invest

... Show More
Scopus (1)
Scopus Crossref
Publication Date
Sat Dec 27 2025
Journal Name
International Journal Of Corrosion And Scale Inhibition
Sustainable corrosion inhibition using Aloe vera extract and its nanocomposites for carbon steel (CS1137) in seawater
...Show More Authors

Two nanocomposite corrosion inhibitors were synthesized from Aloe vera extract: one incorporating sodium thiosulfate and the other silver nitrate. Both nanocomposites were subjected to structural characterization using atomic force microscopy (AFM), which revealed distinct morphological features. The sodium thiosulfate-based nanocomposite exhibited uniform and well-dispersed nanoparticles with an average size of 47.51 nm, suggesting a stable and homogeneous distribution. In contrast, the silver nitrate-based nanocomposite displayed slightly larger particles with an average diameter of 58.34 nm, indicating a tendency toward moderate aggregation. The corrosion inhibition performance of these nanocomposites for carbon steel (CS1137) was invest

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Tue Feb 28 2023
Journal Name
Egyptian Journal Of Chemistry
Application of UV-A light Operating Photoreactor for Green Degradation of Direct Blue 15 through the Photo-Fenton-like process: Effects and Box-Behnken Optimization
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref