Background : Hyperglycosylated hCG a newly discovered variant of hCG which can be used as a predictor of invasion of trophoblastic cells in patient with gestational trophoblastic disease. Objectives : To measure hyperglycosylated human chorionic gonadotrophin and to assess how far it can be used as predictor of invasion in invasive mole and choriocarcinoma. Study design control study. Setting: : Case Gynecological department in Baghdad Teaching Hospital from January 2016 to January 2017. Patient and Methods : 60 women were enrolled in this study 30 of them were with gestational trophoblastic disease (no.= 30 ) the remainder were normal pregnancy (no. =30) , hCG –H level was measured in both groups. Results : Mean serum hCG-H level was significantly higher in patients with gestational trophoblastic disease compared to control women (460.5 ± 168.35 , 206.8± 19.99 ) respectively with p value < 0.05. Mean serum hCG-H level was significantly higher in patients with gestational trophoblastic disease Invasive mole and chriocarcinoma compared to patient with molar pregnancy. Before evacuation (772.11 ± 184.08, 398.27 ±65.86). After evacuation (550.52 ± 146.15 , 340.40 ±85.61). With p value < 0.05. Conclusion : 1) Serum hCG-H level was higher in patients who had invasive mole and patients with choriocarcinoma than patients with gestational trophoblastic disease , so it can be used as a predictor of invasion in patients with invasive mole and choriocarcinoma. 2) Serum hCG-H level can be used in patient with abnormal β- hCG after evacuation when it is slowly decreasing or plateau. 3) It is better to measure the ratio hCG-H/total hCG and using uniform method test and units so we can understand the actual changes that happen in invasion.
Braces in straight bridge systems improve the lateral-torsional buckling resistance of the girders by reducing the unbraced length, while in horizontally curved and skew bridges, the braces are primary structural elements for controlling deformations by engaging adjacent girders to act as a system to resist the potentially large forces and torques caused by the curved or skewed geometry of the bridge. The cross-frames are usually designed as torsional braces, which increase the overall strength and stiffness of the individual girders by creating a girder system that translates and rotates as a unit along the bracing lines. However, when they transmit the truck’s live load forces, they can produce fatigue cracks at their connection
... Show MoreIn this paper, chip and powder copper are used as reinforcing phase in polyester matrix to form composites. Mechanical properties such as flexural strength and impact test of polymer reinforcement copper (powder and chip) were done, the maximum flexural strength for the polymer reinforcement with copper (powder and chip) are (85.13 Mpa) and (50.08 Mpa) respectively was obtained, while the maximum observation energy of the impact test for the polymer reinforcement with copper (powder and chip) are (0.85 J) and (0.4 J) respectively
Linear motor offers several features in many applications that require linear motion. Nevertheless, the presence of cogging force can deteriorate the thrust of a permanent magnet linear motor. Using several methodologies, a design of synchronous single sided linear iron-core motor was proposed. According to exact formulas with surface-mounted magnets and concentrated winding specification, which are relying on geometrical parameters. Two-dimensional performance analysis of the designed model and its multi-objective optimization were accomplished as a method to reduce the motor cogging force using MAXWELL ANSYS. The optimum model design results showed that the maximum force ripple was approximatrly reduced by 81.24%compared to the origina
... Show MoreThis article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs
... Show MoreDouble-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w
... Show MoreImproving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application
In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational
... Show More