In order to promote sustainable steel-concrete composite structures, special shear connectors that can facilitate deconstruction are needed. A lockbolt demountable shear connector (LB-DSC), including a grout-filled steel tube embedded in the concrete slab and fastened to a geometrically compatible partial-thread bolt, which is bolted on the steel section's top flange of a composite beam, was proposed. The main drawback of previous similar demountable bolts is the sudden slip of the bolt inside its hole. This bolt has a locked conical seat lug that is secured inside a predrilled compatible counter-sunk hole in the steel section's flange to provide a non-slip bolt-flange connection. Deconstruction is achieved by demounting the tube from the top of the slab by unfastening using a simple modified wrench. The mechanical behaviour of the proposed connector is assessed by four pushout tests that were conducted per Eurocode 4 recommendations. The tests showed high shear resistance, and high stiffness as compared to other DSCs, while the slip capacity results classified the LB-DSC as a ductile shear connector according to Eurocode 4. A refined nonlinear finite element model (FEM) was validated through the tests and reliably reproduced the experimental behaviour. Consequently, the calibrated FEM model was applied to carry out extensive parametric analyses to investigate the strength and geometry effects of concrete slab, infilled grout, tube, and bolt on the structural behaviour of the LB-DSC. On the basis of numerical and experimental results, a design equation is derived to predict the shear resistance of the LB-DSC.
The concrete need curing for cement hydration that is a chemical reaction in each step require water supply throughout the time period. The traditional concrete cured by external method that prevents the concrete surface dry so that keeping the concrete mixture wet and warm. The internal curing was adopted in normal and high strength concrete such as reactive powder concrete. In present paper, experimental approach is to study the mechanical properties of reactive powder concrete cured internally with thermostone material. The materials that adopted to evaluate and find out the influences of the internal curing on the mechanical properties of reactive powder concrete is focused with d
The incorporation of safety characteristics into the traditional pavement structural design or in the functional evaluation of pavement condition has not been established yet. The design has focused on the structural capacity of the roadway so that the pavement can withstand specific level of repetitive loading over the design life. On the other hand, the surface texture condition was neither included in the AASHTO design procedure nor in the present serviceability index measurements.
The pavement surface course should provide adequate levels of friction and ride quality and maintain low levels of noise and roughness. Many transportation departments perform routine skid resistant testing, the type of equipment us
... Show MoreThis study explores eggshell waste as a low-cost, eco-friendly adsorbent for removing Aniline Blue dye from water. Batch and continuous experiments under various conditions showed effective performance. FTIR and SEM analyses confirmed porosity and functional groups. The adsorption followed the Sips isotherm and pseudo-first-order kinetics. The porous calcium carbonate structure enhanced dye removal. Thermodynamic results indicated an endothermic and spontaneous process. Lower flow rates improved performance in fixed-bed columns. The study supporting environmentally friendly solutions aligned with the Sustainable Development Goals (SDGs).
This study examines the structural performance of concrete-encased pultruded Glass Fiber Reinforced Polymer (GFRP) I-sections with shear connections. It specifically focuses on how different parameters affect the latter’s ductility, flexural strength, and load-carrying capacity. The key variables studied include various shear connector types, spacing, and geometries, as well as the compressive strength of concrete and the properties of GFRP. The finite element modeling and experimental validation show that the shear connectors significantly improve the ductility, ultimate capacity, and load transmission efficiency. The present review emphasizes that the shear connectors greatly enhance the structural performance when they are prop
... Show MoreThis work has been done with using of epoxy resin mixed with Granite powder were weighted by percent volume (5,10,15, and 20)%and then mixed with epoxy polymer to compose polymer composite. Hand lay-up technique is used in fabrication of the composite samples. Hardness test was carried out for the proper samples in both normal condition and after immersion in HCL (1 M and 2 M) solutions for periods ranging up to 10 weeks. After comparing the results between the polymer and their composite, the hardness increased with increasing Granite weight percent, it was found that Hardness were greater for the composites before immersion compared with their values after immersion.
Many cities suffer from the large spread of slums, especially the cities of the Middle East. The purpose of the paper is to study the reality of informal housing in Al-Barrakia and the most important problems that it suffers from. The paper also seeks to study the presence or absence of a correlation between urban safety indicators and urban containment indicators as one of the methods of developing and planning cities. This can be achieved through sustainable urban management. The slums are a source of many urban problems that threaten the security and safety of the residents and represent a focus for the concentration of crimes and drugs. The paper seeks to answer the following question: How can urban safety be improved through urban cont
... Show MoreThis research is devoted to study the strengthening technique for the existing reinforced concrete beams using external post-tensioning. An analytical methodology is proposed to predict the value of the effective prestress force for the external tendons required to close cracks in existing beams. The external prestressing force required to close cracks in existing members is only a part from the total strengthening force.
A computer program created by Oukaili (1997) and developed by Alhawwassi (2008) to evaluate curvature and deflection for reinforced concrete beams or internally prestressed concrete beams is modified to evaluate the deflection and the stress of the external tendons for the externally strengthened beams using Matlab
Concrete pavements are essential to modern infrastructure, but their low tensile and flexural strengths can cause cracking and shrinkage. This study evaluates fiber reinforcement with steel and carbon fibers in various combinations to improve rigid pavement performance. Six concrete mixes were tested: a control mix with no fiber, a mix with 1% steel fiber (SF1%), a mix with 1% carbon fiber (CF1%), and three hybrid mixes with 1% fiber content: 0.75% steel /0.25% carbon fiber (SF0.75CF0.25), 0.25% steel /0.75% carbon fiber (SF0.25CF0.75), and 0.5% steel /0.5% carbon fiber ((SF0.5CF0.5). Laboratory experiments including compressive, flexural, and splitting tensile strength tests were conducted at 7, 28, and 90 days, while Finite Element Analys
... Show More