The present work aimed to examine the nature and degree of the cross-correlations among three different ionospheric indices: these are Optimum Working Frequency (OWF), Highest Probable Frequency (HPF), and Best Usable Frequency (BUF). VOCAP and ASASPS models were adopted to determine the datasets of the selected ionospheric indices. The determination was made for different transceiver stations that provide certain HF connection links during the minimum and maximum years of solar cycle 24, 2009 and 2014, respectively. Matlab program was implemented to produce the geodesic parameters for the selected transceiver stations. The determination was made for different path lengths (500, 1000, 1500, and 2000) Km and bearings (0o, 45o, 90o ........ 315o). Different correlation methods were used to examine the best determination coefficient values between the tested parameters. A third-order polynomial equation was set as the best correlation method that gave a better description for the correlation among the tested parameters. The proposed mathematical correlation equations were used to predict the seasonal values of the (HPF, OWF and BUF) parameters. The proposed equations were verified by comparing their values with the observed datasets during the study years. Also, the predicted values were tested using different statistical methods, which gave good results for all tested cases. يهدف العمل الحالي إلى دراسة طبيعة ودرجة الترابط بين ثلاثة مؤشرات آيونوسفيرية مختلفة وهي (HPF,OWF and BUF), تم استخدام نماذج VOCAP و ASASPS لحساب قيم البيانات للمؤشرات الآيونوسفيرية المختارة. اجريت الحسابات لمحطات الإرسال / الاستقبال المختلفة التي توفر روابط اتصال عالية التردد خلال سنوات الصغرى والعظمى للدورة الشمسية 24 (2009 و 2014) على التوالي. تم تنفيذ برنامج Matlab لايجاد قيم المعلمات الجيوديسية لمحطات الإرسال / الاستلام لأطوال مسافات مختلفة (500، 1000، 1500 و 2000) كم واتجاهات مختلفة(0o, 45o, 90o ........ 315o). تم تطبيق طرق ارتباطية مختلفة لاختبار افضلها بين المعاملات المختبرة . تم اقتراح معادلات رياضية متعددة الحدود (الدرجة الثالثة) كأفضل طريقة تصف القيم الارتباطية بين المعاملات المحددة لغرض الدراسة. تمكنت المعادلات المقترحة من التنبؤ بالقيم الموسمية للمؤشرات ((HPF و(OWF) و (BUF).و تم التحقق منها من خلال مقارنتها مع قيم المعلمات المرصودة خلال سنوات الدراسة . كما تم اختبار القيم المتوقعة باستخدام طرق إحصائية مختلفة والتي قدمت نتائج جيدة لجميع الحالات المختبرة
In this study, different methods were used for estimating location parameter and scale parameter for extreme value distribution, such as maximum likelihood estimation (MLE) , method of moment estimation (ME),and approximation estimators based on percentiles which is called white method in estimation, as the extreme value distribution is one of exponential distributions. Least squares estimation (OLS) was used, weighted least squares estimation (WLS), ridge regression estimation (Rig), and adjusted ridge regression estimation (ARig) were used. Two parameters for expected value to the percentile as estimation for distribution f
... Show MoreThis paper demonstrates an experimental and numerical study aimed to compare the influence of openings of different configurations on the flexural behavior of prestressed concrete rafters. The experimental program consisted of testing six simply supported prestressed concrete rafters; 5 rafters are perforated, and the other one is solid as a reference. All rafters were tested under monotonic midpoint load. The variable which has been investigated in this work was the opening’s configuration (quadrilateral or circular) with the same upper and lower chords depths. The results indicate improvement in the beam flexural behavior using the circular openings compared to the quadrilateral o
Automatic license plate recognition (ALPR) used for many applications especially in security applications, including border control. However, more accurate and language-independent techniques are still needed. This work provides a new approach to identifying Arabic license plates in different formats, colors, and even including English characters. Numbers, characters, and layouts with either 1-line or 2-line layouts are presented. For the test, we intend to use Iraqi license plates as there is a wide range of license plate styles written in Arabic, Kurdish, and English/Arabic languages, each different in style and color. This variety makes it difficult for recent traditional license plate recognition systems and algorithms to recogn
... Show MoreRecently, wireless communication environments with high speeds and low complexity have become increasingly essential. Free-space optics (FSO) has emerged as a promising solution for providing direct connections between devices in such high-spectrum wireless setups. However, FSO communications are susceptible to weather-induced signal fluctuations, leading to fading and signal weakness at the receiver. To mitigate the effects of these challenges, several mathematical models have been proposed to describe the transition from weak to strong atmospheric turbulence, including Rayleigh, lognormal, Málaga, Nakagami-m, K-distribution, Weibull, Negative-Exponential, Inverse-Gaussian, G-G, and Fisher-Snedecor F distributions. This paper extensive
... Show MoreThe nonlinear refractive (NLR) index and third order susceptibility (X3) of carbon quantum dots (CQDs) have been studied using two laser wavelengths (473 and 532 nm). The z-scan technique was used to examine the nonlinearity. Results showed that all concentrations have negative NLR indices in the order of 10−10 cm2/W at two laser wavelengths. Moreover, the nonlinearity of CQDs was improved by increasing the concentration of CQDs. The highest value of third order susceptibility was found to be 3.32*10−8 (esu) for CQDs with a concentration of 70 mA at 473 nm wavelength.
In a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amou
... Show More