Preferred Language
Articles
/
dhZYd4cBVTCNdQwCIVMx
The assessment of pathological changes in cerebral blood flow in hypertensive rats with stress-induced intracranial hemorrhage using Doppler OCT: Particularities of arterial and venous alterations/Die Beurteilung von pathologischen Veränderungen der Hirndurchblutung bei hypertensiven Ratten mit Stress-induzierten intrakraniellen Blutungen mittels Doppler-OCT: Besonderheiten von arteriellen und venösen Veränderungen
...Show More Authors
Abstract<p>Hemorrhagic insult is a major source of morbidity and mortality in both adults and newborn babies in the developed countries. The mechanisms underlying the non-traumatic rupture of cerebral vessels are not fully clear, but there is strong evidence that stress, which is associated with an increase in arterial blood pressure, plays a crucial role in the development of acute intracranial hemorrhage (ICH), and alterations in cerebral blood flow (CBF) may contribute to the pathogenesis of ICH. The problem is that there are no effective diagnostic methods that allow for a prognosis of risk to be made for the development of ICH. Therefore, quantitative assessment of CBF may significantly advance the understanding of the nature of ICH. The aim of this study was to determine the particularities of alterations in arterial and venous cerebral circulation in hypertensive rats at different stages of stress-related development of ICH using three-dimensional Doppler optical coherence tomography (DOCT).</p><p>Experiments were performed in mongrel adult rats. To induce ICH, hypertensive rats underwent stress (effect of severe sound, 120 dB during 2 h). To induce the renal hypertension (two kidneys, one clip) the rats were clipped at the left renal artery with a silver clip. Seven weeks after clipping, the hypertensive rats were used in the experiment. The monitoring of CBF was performed in anesthetized rats with fixed heads using a commercially available swept source OCT system (OCS1300SS; Thorlabs) in the masked period of ICH (4 h after stress) and during ICH (24 h after stress).</p><p>It could be shown that in stressed rats, compared with non-stressed animals, the latent stage of stress-induced ICH (4 h after stress-off) is characterized by an increase in diameter of the superior sagittal vein with decrease in speed of the blood flow in the venous network, whereas no changes in the CBF in the arterial tree were found in this period. These facts suggest that the masked period of ICH is accompanied by decreasing venous outflow and the development of venous insufficiency. The incidence of ICH, 24 h after stress, is associated with progression of pathological alterations in cerebral venous circulation. All hypertensive rats with ICH demonstrated a greater increase in the diameter of the superior sagittal vein than stressed rats at the latent stage of ICH (in 2.5-fold,</p><p>In summary, using DOCT we have shown that the latent stage of stress-induced ICH is characterized by a decrease in venous outflow. The incidence of ICH is associated with the progression of pathological alterations in cerebral venous circulation that is accompanied by a decrease in blood flow in the arterial tree. The evaluation of cerebral venous insufficiency is an important diagnostic approach for the prognosis of the risk of developing cerebral hypotension and ICH.</p>
Scopus Crossref
View Publication
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
Scopus (20)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Positron Annihilation Lifetime Study on free Volume Changes in TLD by Gamma - irradiation
...Show More Authors

Positron annihilation lifetime has been utilized for the first time to investigate the free - volume hole properties in thermolumenscent dosimeter ( TLD ) as a function of gamma-dosc . The hole volume, free volume fraction determined form orthopsitronium lifetime are found to be ?lamatically increase to large values , and then to minimum values as a function ofgamma-dose . The free - volume holes size is found to be 0.163nm’ and to have maximum of 0.166nm^ at the gamma-dose of 0.1 and 0.8 Gy, respectively-

View Publication Preview PDF
Publication Date
Tue Feb 09 2016
Journal Name
Advances In Environmental Biology
A study effect Histological changes
...Show More Authors

Publication Date
Wed Jan 01 2020
Journal Name
Plant Archives
STUDY OF THE EFFECT OF COLD PLASMA ON THE REPRODUCTIVE ENDOCRINOLOGY OF MALE RATS
...Show More Authors

Cold atmospheric plasma (CAP) is used widely in medical and biological fields because of non-thermal effected. Direct application of plasma is preferred in medical functions, so, direct application of cold plasma has obtained by the floating electrode dielectric barrier discharge (FE-DBD) system. The purpose of this paper to review the effect of (CAP) on the reproductive hormones (testosterone, LH, E2, progesterone, for male rats. The study appeared that no significant effect on E2 and progesterone hormone for all time of exposure, besides this significant difference in LH hormone (P<0.05) at 15 sec, (P<0.0001) at 30, 90 sec and (P<0.001) at 60 sec of exposure to plasma. Added to that significant difference (P<0.01) at 15, 30, 60 sec and no

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 31 2017
Journal Name
Journal Of Engineering
Assessment of Water Clarity within Dokan Lake Using Remote Sensing Techniques
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Nov 16 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Postoperative assessment of dental implants by using multi-slice computed tomography
...Show More Authors

Background: Implantology is a fast growing area in dentistry. One of the most common issues encountered in dental implantation procedures is the lack of adequate preoperative planning. Conventional radiography may not be able to assess the true regional three-dimensional anatomical presentation. Multi Slice Computed Tomography provides data in 3-dimentional format offering information on craniofacial anatomy for diagnosis; this technology enables the virtual placement of implant in a 3-Dimensional model of the patient jaw (dental planning). Patients, Material and Methods: The sample consisted of (72) Iraqi patients indicated for dental implant (34 male and 38 female), age range between (20-70) years old. They were examined during a time p

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 01 2022
Journal Name
Baghdad Science Journal
Performance Assessment of Solar-Transformer-Consumption System Using Neural Network Approach
...Show More Authors

Solar energy is one of the immeasurable renewable energy in power generation for a green, clean and healthier environment. The silicon-layer solar panels absorb sun energy and converts it into electricity by off-grid inverter. Electricity is transferred either from this inverter or from transformer, consumed by consumption unit(s) available for residential or economic purposes. The artificial neural network is the foundation of artificial intelligence and solves many complex problems which are difficult by statistical methods or by humans. In view of this, the purpose of this work is to assess the performance of the Solar - Transformer - Consumption (STC) system. The system may be in complete breakdown situation due to failure of both so

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Feb 12 2019
Journal Name
International Journal Of Biosciences
Biomechanical and histological assessment of titanium dental implants coated with strontium substituted hydroxyapatite and fluorapatite mixture
...Show More Authors

Dental implants are considered a unique treatment alternative for the replacement of missing dentition. There is a strive for materials which increase bone formation in bone implant interface and improve osseointegration to offer immediate loading directly after placement with decreased time. The aim of the study was to assess the effect of nano strontium substituted hydroxyapatite and nano fluorapatite mixture coating of screw shaped commercially pure titanium at the bone implant interface by torque removal test and histological assessment in rabbit tibia. Commercially pure titanium was used to prepare 80 screws that were divided into machined surfaces (CpTi), coated with (SrHA), coated with (FA) and coated with mixture 50%SrHA + 50%FA (mi

... Show More
Preview PDF
Publication Date
Sat May 28 2022
Journal Name
Egyptian Journal Of Chemistry
Study the kinetics of electrochemical removal of cobalt from aqueous solutions using a Flow-by Fixed Bed Bio-electrochemical Reactor
...Show More Authors

View Publication
Scopus Clarivate Crossref