Background Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq. Objectives To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women. Subjects and Methods A single arm clinical trial included 150 eligible women who attended Al-Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the uterine cavity immediately after delivery of the placenta during cesarean delivery. The intrauterine device was fixed in place at the fundus using an absorbable suture. Patients were followed up at six weeks, then annually for three years. Results Expulsion of the intrauterine device was not reported by any of the participants. The most-reported complaints in the first twelve months of intrauterine device placement were abdominal pain, abnormal vaginal discharge, and heavy menstrual blood loss, however, none were statically significant (P= 0.256). After the first year, there was a significant reduction in the frequency of complaints (P= 0.002). Only 7.33% (95% CI: 6.92–7.75%) of the patient requested intrauterine device removal within the three years. The main reason was to plan a new pregnancy followed by recurrent infection associated with uncontrolled diabetes mellitus. Diabetes was a significant predictor …
Abstract in English The aim of this study is to identify the effectiveness of rehabilitation exercises in conjunction with aquatic therapy for those suffering from sacroiliitis in football players. The researcher used the experimental approach, using the experimental design (pre-measurement, post-measurement). Similar to the objectives and procedures of the research, the researcher assumed the following: the existence of significant differences. Statistics between pre- and post-measurements in variables in favor of post-measurement for the following variables (degree of pain and level of balance). The experimental approach was used with a pre- and post-measurement design on one group of football players with sacroiliitis, nu
... Show MoreAbstract Background: The human epidermal growth factor receptor 2(HER2) proto-oncogene is overexpressed or amplified in approximately 15%-25% of invasive breast cancers. Approximately 35% of HER2-amplified breast cancers have coamplification of the topoisomerase II-alpha (TOP2A) gene encoding an enzyme that is a major target of anthracyclines. Hence, the determination of genetic alteration (amplification or deletion) of both genes is considered as an important predictive factor that determines the response of breast cancer patients to treatment. The aims of this study are to determinate TOP2A status gene amplification in a set of Iraqi patients with breast cancer that have had an equivocal (2+) and positive HER2/neu by immunohistochemistry
... Show MoreBackground: The ultimate purpose of this prospective study is to estimate and measure swelling associated with surgical extrac¬tion of impacted mandibular third molars in different four post-operative times and to identify the risk factors associated with determination of their risk degree. Material and Methods: In this prospective cohort study 159 consecutive cases in which removal of impacted lower third molars in 107outpatients were evaluated. Five groups of variables have been studied which are regarded as a potential factor for swelling after mandibular third removal which will enable the surgeon to predict and counsel high risk patients in order to offer a preventive strategy. Results: Facial measurements were carried out on 1st, 2
... Show MoreThe current paper aims to identify potential factors associated with employees’ intentions to leave information and communication technology companies in Iraq. There is evident variability in the literature regarding these factors; hence, a factor analysis approach was employed to identify these factors within the surveyed environment. Due to the difficulty in precisely delineating the size of the research population, a purposive sampling method was employed to reach an appropriate number of respondents within the aforementioned companies. A total of 288 employees responded to the survey conducted via Google Forms. The test results revealed the presence of five primary factors associated with employees’ intentions to leave, name
... Show MoreIn this paper the experimentally obtained conditions for the fusion splicing with photonic crystal fibers (PCF) having large mode areas were reported. The physical mechanism of the splice loss and the microhole collapse property of photonic crystal fiber (PCF) were studied. By controlling the arc-power and the arc-time of a conventional electric arc fusion splicer (FSM-60S), the minimum loss of splicing for fusion two conventional single mode fibers (SMF-28) was (0.00dB), which has similar mode field diameter. For splicing PCF (LMA-10) with a conventional single mode fiber (SMF-28), the loss was increased due to the mode field mismatch.
60 patients diagnosed as having urticaria were included in the study ; 30 patients were effected with acute urticaria and 30 patients were affected with chronic urticaria. In addition, 30 healthy adult volunteers were selected as control group .The patients and control groups sera were examined with enzyme linked immunosorbent assay ( ELISA) to detect total level IgE and radial immunodiffusion (RID) to detect levels of IgG , IgA and IgM . The total level of IgE in acute urticaria ( 1.45±0.13) IU/mL and chronic urticaria (2.12 ± 0.10) IU/mL patients were significantly higher than the control groups ( 0.85 ± 0.10)IU/mL (p<0.05). The level of IgG in acute urticaria ( 12.5± 0.42) g/L and chronic (13.16±0.40) g/L patients , IgA in acute (2.
... Show MoreColorectal cancer (CRC), the second most fatal cancer and the 3rd most common cancer is expected to cause 0.9 million deaths globally in 2025. Carcinoembryonic antigen (CEA) is currently used in the follow-up of patients with colorectal cancer, and in this study, we are trying to find a better marker than CEA in following up on patients' health and knowing the effectiveness of the treatment used and as a diagnostic marker for colorectal cancer. To determine the significance of Cancer antigen 72-4 (CA72-4) as a prognosis predictor in patients with colorectal cancer, compare its prognostic validity to the CEA biomarker. this case-control study includes (150) participants, 100 patients (59 males and 41 females), and 50 healthy controls
... Show MoreThis study aimed to assess the possible association of oxytocin (OXT) gene with reproductive traits in two groups of Awassi ewes that differ in their reproductive potentials. Sheep were genotyped using PCR—single-stranded conformation polymorphism approach. Three genotypes were detected in exon 2, CC, CA, and AA, and a novel SNP was identified with a missense effect on oxytocin (c.188C > A → p.Arg55Leu). A significant (p < 0.01) association of p.Arg55Leu with the twinning rate was found as ewes with AA and CA genotypes exhibited, respectively a lower twinning ratio than those with the wild-type CC genotype. The deleterious impact of p.Arg55Leu was demonstrated by all in silico tools that were utilized to assess the effect of this varian
... Show MoreIn order to reduce the environmental pollution associated with the conventional energy sources and to achieve the increased global energy demand, alterative and renewable sustainable energy sources need to be developed. Microbial fuel cells (MFCs) represent a bio-electrochemical innovative technology for pollution control and a simultaneous sustainable energy production from biodegradable, reduced compounds. This study mainly considers the performance of continuous up flow dual-chambers MFC
fueled with actual domestic wastewater and bio-catalyzed with anaerobic aged sludge obtained from an aged septic tank. The performance of MFCs was mainly evaluated in terms of COD reductions and electrical power output. Results revealed that the C