Preferred Language
Articles
/
dXgp4qABuRolNscL8_Tb
Experimental Optimization of PLC-Integrated Multi-Loop PID Control for a Three-Level Electro-Hydraulic Elevator Using PSO and Cheetah Optimizer
...Show More Authors

This study presents the design, modeling, and experimental evaluation of a three-level electro-hydraulic elevator system controlled by a Delta DVP-20SX2 Programmable Logic Controller (PLC) equipped with an integrated Proportional–Integral–Derivative (PID) module. The PLC, programmed in Ladder Logic using ISPSoft 2.46, regulates cabin motion across all three levels. A detailed MATLAB/Simulink model was developed, incorporating three PID controllers: one for displacement regulation via a proportional directional control valve and two for dynamic pressure regulation using a proportional pressure relief valve. Conventional PID parameters were initially tuned using the trial-and-error method based on time-domain performance indices and subsequently optimized using Particle Swarm Optimization (PSO) and the Cheetah Optimizer (CO). The optimized controllers are referred to as PSO-PID and CO-PID, respectively. The error standard used for the electro-hydraulic elevator control system is the Integral Time-weighted Absolute Error (ITAE) type. This study addresses the need to improve dynamic performance and control accuracy in electro-hydraulic elevator systems under maximum load conditions. Experimental results obtained under a 30 kg load for the displacement response showed that PSO-PID reduced rise time by 36.8% and settling time by approximately 37.2% while improving steady-state accuracy by nearly 80% compared with the conventional PID. The CO-PID controller further improved performance, achieving additional reductions of 13.6% in rise time and 13.8% in settling time relative to PSO-PID, as well as decreasing steady-state error by 37.5%. Overall, CO-PID achieved substantial reductions in rise and settling times (up to 45.4% and 45.7%, respectively) and improved steady-state accuracy by nearly 87% compared with the traditional PID. In pressure control loops, PSO-PID reduced settling time by up to 12.8%, whereas CO-PID achieved up to 16.4% faster stabilization relative to the conventional PID. The experimental results were in agreement with the developed MATLAB/Simulink model, confirming the high accuracy of the simulation in representing the system dynamics. These findings demonstrate the superior responsiveness, stability, and efficiency of the CO-PID controller for electro-hydraulic elevator applications.

Scopus Crossref
View Publication
Publication Date
Wed Oct 18 2023
Journal Name
Ieee Access
A New Imputation Technique Based a Multi-Spike Neural Network to Handle Missing Data in the Internet of Things Network (IoT)
...Show More Authors

View Publication
Scopus (13)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sun Oct 19 2025
Journal Name
Lecture Notes In Networks And Systems
Challenges of Using Literary Translation and Artificial Intelligence for Postgraduate Students: A Case Study of Baghdad University
...Show More Authors

Scopus (1)
Scopus Crossref
Publication Date
Sun Dec 30 2018
Journal Name
Journal Of Pure And Applied Microbiology (jpam)
Optimization Kerosene Bio-degradation by a Local Soil Bacterium Isolate Klebsiella pneumoniae Sp. pneumonia
...Show More Authors

Isolated Bacteria from the roots of barley were studied; two stages of processes Isolated and screening were applied in order to find the best bacteria to remove kerosene from soil. The active bacteria are isolated for kerosene degradation process. It has been found that Klebsiella pneumoniae sp. have the highest kerosene degradation which is 88.5%. The optimum conditions of kerosene degradation by Klebsiella pneumonia sp. are pH5, 48hr incubation period, 35°C temperature and 10000ppm the best kerosene concentration. The results 10000ppm showed that the maximum kerosene degradation can reach 99.58% after 48 h of incubation. Higher Kerosene degradation which was 99.83% was obtained at pH5. Kerosene degradation was found to be maximum at 3

... Show More
Crossref (7)
Crossref
Publication Date
Sun Dec 30 2018
Journal Name
Journal Of Pure And Applied Microbiology
Optimization Kerosene Bio-degradation by a Local Soil Bacterium Isolate Klebsiella pneumoniae Sp. pneumonia
...Show More Authors

Isolated Bacteria from the roots of barley were studied; two stages of processes Isolated and screening were applied in order to nd the best bacteria to remove kerosene from soil. The acve bacteria are isolated for kerosene degradaon process. It has been found that Klebsiella pneumoniae sp. have the highest kerosene degradaon which is 88.5%. The opmum condions of kerosene degradaon by Klebsiella pneumonia sp. are pH5, 48hr incubaon period, 35°C temperature and 10000ppm the best kerosene concentraon. The results 10000ppm showed that the maximum kerosene degradaon can reach 99.58% aer 48 h of incubaon. Higher Kerosene degradaon which was 99.83% was obtained at pH5. Kerosene degradaon was found

... Show More
Crossref (7)
Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Engineering Science And Technology (jestec)
ADAPTIVE D2D COMMUNICATION WITH INTEGRATED IN-BAND AND OUT-BAND SPECTRUM BY EMPLOYING CHANNEL QUALITY INDICATOR
...Show More Authors

Scopus (4)
Scopus
Publication Date
Thu Jan 01 2026
Journal Name
Sustainable Civil Infrastructures
Using Artificial Intelligence Algorithms to Predict the Physical Fitness Level in Iraqi Premier League Football Players
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Jun 28 2022
Journal Name
Research Journal Of Pharmacy And Technology
A Case-control Study to Determine Metalloproteinase-12 and Lysyl Oxidase Levels in Iraqi women with Osteoporosis
...Show More Authors

The current study aimed to ascertain the levels of matrix metalloproteinase-12 (MMP-12) and Lysyl oxidase (LOX) in osteoporosis patients and their correlation with alkaline phosphatase (ALP), magnesium (Mg), vitamin D (Vit D), calcium (Ca), phosphorus (P), and T-score %. 110 participants recruited from Baghdad Teaching Hospital, Iraq, were enrolled in this study from November 2019 to March 2020). The participants were divided into two groups: Group 1 comprised 60 osteoporotic women and group 2 consisted of 50 healthy women. (MMP and LOX) were estimated using a quantitative enzyme-linked immunosorbent assay (ELISA. The results showed significant differences in serum LOX, age, ALP, Mg, and T-score %, while no significant differences i

... Show More
View Publication
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Tue Jul 01 2025
Journal Name
Journal Of Breast Diseases
Association Between Serum Interleukin-41 Levels and Breast Cancer Status: A Case–Control Study in Iraqi Women
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
EXPERIMENTAL AND THEORETICAL STUDY OF TWO-PHASE HEAT PIPE
...Show More Authors

In this study, thermal characteristics of a two-phase closed heat pipe were investigated experimentally and theoretically. A two-phase closed heat pipe (copper container, Fluorocarbon FC-72 (C6F14) working fluid) was fabricated to examine its performance under the effect of input heat flux range of 250–1253 W/m2 , 70% fill charge ratio and various tilt angles. The temperature distribution along the heat pipe, input heat to evaporator section, and output heat from condenser were monitored. A comprehensive mathematical model was developed to investigate the steadystate heat transfer performance of a two-phase closed heat pipe. A steady state analytical model, is presented to determine important parameters on the design of two-phase close

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jul 01 2011
Journal Name
Energy
Experimental and numerical analysis of electrical metal foam heater
...Show More Authors

A novel concept of air heater using a heating element made from Aluminum metal porous disc surrounded by a DC resistive electrical heater inserted in the mid-plane of a copper tube of (52.8 mm) diameter and (480 mm) length is presented herein. Study of the developed heater is conducted; using different porous disc thicknesses of (20, 40, 60 mm), heater wall temperatures (106 °C and 119 °C), and flow rates rare varied from (100–300 L/min). Al-metal foam disc has been made using the metal powder technology. Different resistive electrical heaters according to the type of porous disc used have been manufactured. A 2-D computational model is developed, using continuity, momentum, and energy equations for turbulent forced flow in plain tube,

... Show More
View Publication
Scopus (16)
Crossref (13)
Scopus Crossref