novel spectrofluorimetric flow injection analysis (FIA) method was developed for the selective quantification of ascorbic acid via fluorescence quenching of serotonin hydrochloride. The system employs a custom-designed photometric array comprising 16 irradiation sources arranged in a dual-axis matrix—eight aligned horizontally and eight orthogonally, enabling multi-angle excitation and enhanced spectral resolution. Fluorescence signals were captured using a twin-pair solar cell detector, offering high sensitivity and minimal optical interference. The method exhibited a linear calibration range of 0.1–30 limit of detection (LOD) of 0.025 μ μ g/mL with a correlation coefficient (r mol /L, equivalent to 4.403 * 10 4 μ 2 ) of 0.9966, a g/mL per sample (0.1 mL (and limit of quantitative (LOQ) of 99.381 * 10 3 μ g/ml. Precision and accuracy were confirmed through intra- and inter-day validation, yielding relative standard deviations (RSD) below 2% and recovery rates exceeding 99%. Statistical comparison with conventional fluorometric techniques using a paired t-test revealed no significant difference at the 95% confidence level (p > 0.05), affirming the method's reliability. The proposed system supports high- throughput analysis of up to 50 samples per hour, with reduced reagent consumption and minimal environmental impact. Its robustness, cost-efficiency, and analytical performance render it a promising tool for routine pharmaceutical quality control and environmental monitoring
An experimental and theoretical study has been done to investigate the thermal performance of different types of air solar collectors, In this work air solar collector with a dimensions of (120 cm x90 cm x12 cm) , was tested under climate condition of Baghdad city with a (43° tilt angel) by using the absorber plate (1.45 mm thickness, 115 cm height x 84 cm width), which was manufactured from iron painted with a black matt.
The experimental test deals with five types of absorber:-
Conventional smooth flat plate absorber , Finned absorber , Corrugated absorber plate, Iron wire mesh on absorber And matrix of porous media on absorber .
The hourly and average efficiency of the collectors
... Show MoreThe aim of this study is to utilize the electromembrane extraction (EME) system as a manner for effective removal of zinc from aqueous solutions. A novel and distinctive electrochemical cell design was adopted consisting of two glass chambers, a supported liquid membrane (SLM) housing a polypropylene flat membrane infused with 1-octanol and a carrier. Two electrodes were used, a graphite as anode and a stainless steel as cathode. A comprehensive examination of several influential factors including the choice of carrier, the applied voltage magnitude, the initial pH of the donor solution, and the initial concentration of zinc was performed, all in a concerted effort to ascertain their respective impacts on the efficiency of zinc elim
... Show MoreBackground: Polycystic ovary syndrome (PCOS) is a common endocrine disorder in women of reproductive age with primary manifestations of infertility, menstrual dysfunction and clinical or biochemical hyperandrogenism (hirsutism, acne and elevated androgen). Adiponectin is the most abundant adipokine. It has insulin-sensitizing, anti-atherogenic, and antiinflammatory actions.Objective: Low adiponectin levels in women with PCOS have been largely attributed to obesity which is common among these patients. Therefore, the aim of this study was to measure adiponectin levels in normal weight women with PCOS and its contribution to development of disease.Subjects and Methods: Fifty two (52) women were included in this study with age ra
... Show MoreLiquid-Liquid Extraction of Cu(II) ion in aqueous solution by dicyclohexyl-18-crown-6 as extractant in dichloroethane was studied .The extraction efficiency was investigated by a spectrophometric method. The reagent form a coloured complex which has been a quantitatively extracted at pH 6.3. The method obeys Beer`s law over range from (2.5-22.5) ppm with the correlation coefficient of 0.9989. The molar absorptivity the stoichiometry of extracted complex is found to be 1:2. the proposed method is very sensitive and selective.
Alterations of trace element concentrations adversely affect biological processes and could promote carcinogenesis. Trace element deficiency or excess is implicated in the development or progression of some cancers like colorectal cancer. The aim of the present study was to compare the serum copper (Cu) and zinc (Zn) concentrations in patients with colorectal cancer from Iraqi male patient with those of healthy subjects. During the period of March 2015 until august 2015, a total of 25 patients with metastatic colon cancer and 20 healthy volunteers were enrolled from the Al-Kadhimia Teaching Hospital after the diagnosis using a histopathological examination for the malignant tumor; their age was between (38-60) years. Higher levels o
... Show MoreA reversed-phase HPLC method with fluorescence detection for the determination of the aflatoxins B1, B2, G1 and G2 in 42 animal feeds, comprising corn (16), soya bean meal (8), mixed meal (13), sunflower, wheat, canola, palm kernel, copra meals (1 each) was carried out. The samples were first extracted using acetonitrile:water (9:1), and was further cleaned-up using a multifunctional column. Optimum conditions for the extraction and chromatographic separation were investigated. By adopting an isocratic chromatographic system using a mobile phase comprising acetonitrile:methanol:water (8:27:65, v/v/v), the separation of the four aflatoxins was possible within 30 min. Recoveries for aflatoxins B1, B2, G1 and G2 were 98 ± 0.7%, 95 ± 1.0%, 94
... Show MoreThis work reports the development of an analytical method for the simultaneous analysis of three fluoroquinolones; ciprofloxacin (CIP), norfloxacin (NOR) and ofloxacin (OFL) in soil matrix. The proposed method was performed by using microwave-assisted extraction (MAE), solid-phase extraction (SPE) for samples purification, and finally the pre-concentrated samples were analyzed by HPLC detector. In this study, various organic solvents were tested to extract the test compounds, and the extraction performance was evaluated by testing various parameters including extraction solvent, solvent volume, extraction time, temperature and number of the extraction cycles. The current method showed a good linearity over the concentration ranging from
... Show More