Preferred Language
Articles
/
dOaCbp0BmraWrQ4dkVdq
Advanced spectrofluorimetric determination of ascorbic acid via serotonin hydrochloride quenching using a twin solar cell device with eight-angled blue radiation sources
...Show More Authors

novel spectrofluorimetric flow injection analysis (FIA) method was developed for the selective quantification of ascorbic acid via fluorescence quenching of serotonin hydrochloride. The system employs a custom-designed photometric array comprising 16 irradiation sources arranged in a dual-axis matrix—eight aligned horizontally and eight orthogonally, enabling multi-angle excitation and enhanced spectral resolution. Fluorescence signals were captured using a twin-pair solar cell detector, offering high sensitivity and minimal optical interference. The method exhibited a linear calibration range of 0.1–30 limit of detection (LOD) of 0.025 μ μ g/mL with a correlation coefficient (r mol /L, equivalent to 4.403 * 10 4 μ 2 ) of 0.9966, a g/mL per sample (0.1 mL (and limit of quantitative (LOQ) of 99.381 * 10 3 μ g/ml. Precision and accuracy were confirmed through intra- and inter-day validation, yielding relative standard deviations (RSD) below 2% and recovery rates exceeding 99%. Statistical comparison with conventional fluorometric techniques using a paired t-test revealed no significant difference at the 95% confidence level (p > 0.05), affirming the method's reliability. The proposed system supports high- throughput analysis of up to 50 samples per hour, with reduced reagent consumption and minimal environmental impact. Its robustness, cost-efficiency, and analytical performance render it a promising tool for routine pharmaceutical quality control and environmental monitoring

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Nov 01 2008
Journal Name
Journal Of Physical Science
Spectrophotometric Determination of Allopurinol in Tablet Formulation
...Show More Authors

A new spectrophotometric method for the determination of allopurinol drug was investigated. The proposed method was based on the reaction of the intended drug with catechol and Fe(II) to form a blue soluble complex which was measured at λmax 580 nm. A graph of absorbance versus concentration shown that Beer’s law was obeyed over the concentration range of 2–10 μg ml–1 with molar absorptivity of 9.4 x 103 l mol–1 cm–1 and Sandell sensitivity of 1.4 x 10–2 μg cm–2. A recovery percentage of 100% with RSD of 1.0%–1.3% was obtained. The proposed method was applied successfully for the determination of allopurinol drug in tablets with a good accuracy and

Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
Removal of Malachite Green from Aqueous Solution using Ficus Benjamina Activated Carbon-Nonmetal Oxide synthesized by pyro Carbonic Acid Microwave
...Show More Authors

Activated carbon derived from Ficus Binjamina agro-waste synthesized by pyro carbonic acid microwave method and treated with silicon oxide (SiO2) was used to enhance the adsorption capability of the malachite green (MG) dye. Three factors of concentration of dye, time of mixing, and the amount of activated carbon with four levels were used to investigate their effect on the MG removal efficiency. The results show that 0.4 g/L dosage, 80 mg/L dye concentration, and 40 min adsorption duration were found as an optimum conditions for 99.13% removal efficiency. The results also reveal that Freundlich isotherm and the pseudo-second-order kinetic models were the best models to describe the equilibrium adsorption data.

 

View Publication Preview PDF
Scopus (8)
Crossref (3)
Scopus Crossref
Publication Date
Thu Dec 31 2015
Journal Name
Al-khwarizmi Engineering Journal
Effect of Acetic Acid on Electrochemical Behavior of Sealed AA2319-T3 Al-Alloys Anodized in Phosphoric Acid Electrolytes
...Show More Authors

Abstract

      The present study investigates the effect of acetic acid on corrosion behavior and its potential of hydrothermally sealed anodized AA2319-Al-alloys. Anodizing treatment was performed in stagnant phosphoric acid electrolyte with or without addition of acetic acid. Hydrothermal sealing was carried out in boiling water for each anodized specimen. The open circuit potential of the unsealed and sealed anodized samples was examined using open circuit potential measurement for the purpose of starting in scanning polarization diagrams. The potentiostatic polarization technique measurements were performed to assess corrosion behavior and sealing quality (i.e., degree of sealing) of

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 13 2026
Journal Name
Al–bahith Al–a'alami
Satellite TV sites among the Iraqi public's sources about the demonstrations Field study in Baghdad 2020
...Show More Authors

This research is based on the idea of showing the extent to which the public relies on satellite channels as sources for news of the demonstrations in Iraq .This was the essence of the problem for which the researcher set several goals, including knowing the public’s confidence in the news of these satellite channels and comparing them with others. The researcher chose an available intended sample of (117) respondents in Baghdad - Karkh and Rusafa by adopting the survey method and applying a questionnaire form and the theory of media dependence for the period from 15/11/2019 to 1/1/2021 . By using statistical methods, the researcher reached many results, the most important of which are: Satellite channels are a source for 79% of the pu

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed May 24 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Direct and Indirect Spectrophotometric Determination of Paracetamol in Pharmaceutical Preparations By Oxidative Coupling With p-Amino-2-hydroxy Sodium Benzoate
...Show More Authors

New simple and sensitive spectrophotometric methods for the determination of paracetamol in aqueous medium were developed. The first method is based on coupling of paracetamol with p-amino-2-hydroxy sodium benzoate (AHB) in the presence of sodium periodate, as oxidizing agent, to form a brownish-orange compound which shows a λmax at 470 nm. The molar absorptivity (εmax) of the colored product was found to be (3371) l. mole1. cm-1 and Sandel’s index 0.0449 μg. cm-2. The method follows Beer’s law in the concentration range of 12.5-500.0 μg of paracetamol in a final volume of 25 ml (0.5-20.0) μg. ml-1 with relative standard deviation percent (RSD%) ranged between 0.26-4.71% and accuracy, expressed by recovery percent, 95-106% for five

... Show More
Publication Date
Sat Mar 01 2014
Journal Name
Food Chemistry
Micro-solid phase extraction with liquid chromatography–tandem mass spectrometry for the determination of aflatoxins in coffee and malt beverage
...Show More Authors

A single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1

... Show More
View Publication
Scopus (65)
Crossref (64)
Scopus Clarivate Crossref
Publication Date
Wed Feb 01 2017
Journal Name
Journal Of Natural Gas Science And Engineering
Experimental determination of hydrate phase equilibrium for different gas mixtures containing methane, carbon dioxide and nitrogen with motor current measurements
...Show More Authors

Hydrate dissociation equilibrium conditions for carbon dioxide + methane with water, nitrogen + methane with water and carbon dioxide + nitrogen with water were measured using cryogenic sapphire cell. Measurements were performed in the temperature range of 275.75 K–293.95 K and for pressures ranging from 5 MPa to 25 MPa. The resulting data indicate that as the carbon dioxide concentration is increased in the gas mixture, the gas hydrate equilibrium temperature increases. In contrast, by increasing the nitrogen concentration in the gas mixtures containing methane or carbon dioxide decreased the gas hydrate equilibrium temperatures. Furthermore, the cage occupancies for the carbon dioxide + methane system were evaluated using the Van der Wa

... Show More
Scopus (97)
Crossref (95)
Scopus Clarivate Crossref
Publication Date
Sun Feb 02 2025
Journal Name
Engineering, Technology & Applied Science Research
A Numerical Study of Concrete Composite Circular Columns encased with GFRP I-Section using the Finite Element Method
...Show More Authors

This paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Microchemical Journal
A flow analysis system integrating an optoelectronic detector for the quantitative determination of active ingredients in pharmaceutical formulations
...Show More Authors

View Publication Preview PDF
Scopus (24)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Microchemical Journal
A flow analysis system integrating an optoelectronic detector for the quantitative determination of active ingredients in pharmaceutical formulations
...Show More Authors

Scopus (25)
Crossref (18)
Scopus Clarivate Crossref