Preferred Language
Articles
/
dIbhtoYBIXToZYALl7M1
Post-Fire Behavior of Post-Tensioned Segmental Concrete Beams under Monotonic Static Loading
...Show More Authors

This paper presents a study to investigate the behavior of post-tensioned segmental concrete beams that exposed to high-temperature. The experimental program included fabricating and testing twelve simply supported beams that divided into three groups depending on the number of precasting concrete segments. All specimens were prepared with an identical length of 3150 mm and differed in the number of the incorporated segments of the beam (9, 7, or 5 segments). To simulate the genuine fire disasters, nine out of twelve beams were exposed to a high-temperature flame for one hour. Based on the standard fire curve (ASTM – E119), the temperatures of 300◦C (572◦F), 500◦C (932◦F), and 700◦C (1292◦F) were adopted. Consequently, the beams that exposed to be cool gradually under the ambient laboratory condition, after that, the beams were loaded till failure to investigate the influence of the heating temperature on the performance during the serviceability and the failure stage. It was observed that, as the temperature increased in the internal layers of concrete, the camber of tested beams increased significantly and attained its peak value at the end of the time interval of the stabilization of the heating temperature. This can be attributed to the extra time that was consumed for the heat energy to migrate across the cross-section and to travel along the span of the beam and deteriorate the texture of the concrete causing microcracking with a larger surface area. Experimental findings showed that the load-carrying capacity of the test specimen, with the same number of incorporated concrete segments, was significantly decreased as the heating temperature increased during the fire event.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 15 2020
Journal Name
Al-academy
Aesthetics of the Sufi Image and its Representations in Post-Modern Theater Show: فرحان عمران موسى
...Show More Authors

  Sufism has aesthetic signs linked to the human spirit and adopts a set of spiritual, motor and tonal practices, let alone the philosophical aspects that have been tackled in the epics, novels and theatrical texts, the theatrical show can recall the Sufi image and its aesthetics within the operating and image system of the theatrical show.. The research problem resides in how to employ the Sufi image in the theatrical show. The research consists introduction of the research subject, the problem, the importance, and objectives represented by uncovering the aesthetic and intellectual representations of the Sufi image in the theatrical show. the theoretical foundation within two sections: the first highlighted the concept of (Sufism a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi National Journal Of Nursing Specialties
Nurses' Practices regarding Patients Discharge Planning post Cardiac Surgery at Cardiac Centers in Baghdad city
...Show More Authors

Objective (s): to assess nurses' practices regarding discharge planning post-cardiac surgery and to find out the relationship between nurse practices and demographic characteristic (age, gander, level of education, years of experiences, and years of experiences in surgical ward).
Methodology: A descriptive study was carried out at cardiac centers and hospitals in Baghdad (Ibn Al- Bitar specialized center for cardiac surgery; Iraqi center for heart disease and Ibn al Nafees hospital). For the period of 6th February 2017 up to 1st of June 2018. A non-probability (purposive) sample of (58) nurses (male & female) who were working in surgical wards. The data was collected, by using of a questionnaire, which consists of two parts, part

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi National Journal Of Nursing Specialties
Functional Performance For Patients Post Heart's Valves Replacement at Cardiac Surgery Centers in Baghdad City
...Show More Authors

Abstract
Objectives: The study is carried out to assess functional performance for heart's valve replacement patients and find out relationship with sociodemographic data and clinical data
Methodology: Descriptive design is carried out at cardiac surgery centers in Baghdad ; Ibn -Al Betar Specialized for cardiac surgery center and Al-Iraqi center for cardiac disease. its initiation from December28the 2013 to September 1st 2014,A non- probability (purposive) sample of 50 adults patients are attended cardiac surgery centers at Baghdad city and who have heart valves replacement. The data collection through development of questionnaire which is composed from three parts(socio demographic data, clinical information, functional performa

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 01 2018
Journal Name
J. Pharm. Sci. & Res
Periodontal health status for post-menopausal women with and without osteoporosis (Clinical and radiographical study)
...Show More Authors

Scopus (3)
Scopus
Publication Date
Fri Nov 12 2021
Journal Name
Transportation Infrastructure Geotechnology
Numerical Modeling of Pullout Capacity of Screw Piles Under Seismic Loading in Layered Soil
...Show More Authors

View Publication
Scopus (3)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Jun 15 2021
Journal Name
Al-academy
Forms of post-modernism in performance of Iraqi theatre "dream of Baghdad exam": عمار عبد سلمان محمد
...Show More Authors

  The effects of postmodernism on theatrical form was managed by the director (Anas Abdul Samad) to be employed in the Iraqi play (Dream in Baghdad) and the researcher sought to study this problem and divided it into four chapters dealt with in the first chapter the problem of research and its need, the importance of research, As well as the definition of terminology, either Chapter II theoretical framework divided by the researcher to the first two is the postmodernism in the theater is the most prominent reference references and the second most important postmodern applications in the world play and then the researcher concluded the second chapter of the most important indicators. In the third chapter, the researcher identified th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2019
Journal Name
Iop Conf. Series: Materials Science And Engineering
Fire flame effect on the compressive strength of reactive powder concrete using different methods of cooling
...Show More Authors

This research foxed on the effect of fire flame of different burning temperatures (300, 400 and 500)oC on the compressive strength of reactive powder concrete (RPC).The steady state duration of the burning test was (60)min. Local consuming material were used to mixed a RPC of compressive strength around (100) MPa. The tested specimens were reinforced by (3.0) cm hooked end steel fiber of (1100) MPa yield strength. Three steel fiber volume fraction were adopted in this study (0, 1.0and 1.5)% and two cooling process were included, gradual and sudden. It was concluding that increasing burning temperature decreases the residual compressive strength for RPC specimens of(0%) steel fiber volume fraction by (12.16, 19.46&24.49) and (18.20, 27.77 &3

... Show More
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Aug 21 2021
Journal Name
Engineering, Technology & Applied Science Research
The Impact of Hybrid Fibers on Punching Shear Strength of Concrete Flat Plates Exposed to Fire
...Show More Authors

This study presents an investigation about the effect of fire flame on the punching shear strength of hybrid fiber reinforced concrete flat plates. The main considered parameters are the fiber type (steel or glass) and the burning steady-state temperatures (500 and 600°C). A total of 9 half-scale flat plate specimens of dimensions 1500mm×1500mm×100mm and 1.5% fiber volume fraction were cast and divided into 3 groups. Each group consisted of 3 specimens that were identical to those in the other groups. The specimens of the second and the third groups were subjected to fire flame influence for 1 hour and steady-state temperature of 500 and 600°C respectively. Regarding the cooling process, water sprinkling was applied directly aft

... Show More
View Publication
Crossref (9)
Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Behavior of Partially Saturated Cohesive Soil under Strip Footing
...Show More Authors

In this paper, a shallow foundation (strip footing), 1 m in width is assumed to be constructed on fully saturated and partially saturated Iraqi soils, and analyzed by finite element method. A procedure is proposed to define the H – modulus function from the soil water characteristic curve which is measured by the filter paper method. Fitting methods are applied through the program (SoilVision). Then, the soil water characteristic curve is converted to relation correlating the void ratio and matric suction. The slope of the latter relation can be used to define the H – modulus function. The finite element programs SIGMA/W and SEEP/W are then used in the analysis. Eight nodded isoparametric quadrilateral elements are used for modeling

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Civil Engineering Journal
Structural Behavior of BubbleDeck Slab under Uniformly Distributed Load
...Show More Authors

In structural construction fields, reducing the overall self-weight of the structure is considered a primary objective and substantial challenge in the civil engineering field, particularly in earthquake-affected buildings and tall buildings. Different techniques were implemented to attain this goal; one of them is setting voids in a specific position through the structure, just like a voided slab or BubbleDeck slab. The main objective of this research is to study the structural behavior of BubbleDeck reinforced concrete slabs under the effect of static uniformly distributed load. The experimental program involved testing five fixed-end supported two-way solid and BubbleDeck slabs of dimensions 2500×2500×200 mm. The considered par

... Show More
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref