Consequence of thermal and concentration convection on peristaltic pumping of hyperbolic tangent nanofluid in a non‐uniform channel and induced magnetic field is discussed in this article. The brief mathematical modeling, along with induced magnetic field, of hyperbolic tangent nanofluid is given. The governing equations are reduced to dimensionless form by using appropriate transformations. Exact solutions are calculated for temperature, nanoparticle volume fraction, and concentration. Numerical technique is manipulated to solve the highly non‐linear differential equations. The roll of different variables is graphically analyzed in terms of concentration, temperature, volume fraction of nanoparticles, axial induced magnetic field, magnetic force function, stream functions, pressure rise, and pressure gradient.
Both methotrexate and vitamin D3 are used in combination for the treatment of various diseases. The aim of this study is to highlight the effect of vitamin D3 on methotrexate-induced jejunum damage using biochemical and histopathological studies. Seven groups of both sexes of rats were selected and treated as follows: (Group I and Group II) : control 1,control 2 (I.P normal saline) daily for 14 and 21 days respectively ; (Group III and Group IV) :vitamin D3 groups (500 IU/rat/day) orally for 14 and 21 days, respectively;(Group V): once daily dose of methotrexate 20mg/kg, I.P injected for 4 days;(Group VI):vitamin D3 (500 IU/rat/day) once daily for 14 days and methotrexate (20 mg/kg I.P) injected only at day 10;.(Group
... Show MoreTenofovir disoproxil fumarate, a nucleotide reverse transcriptase inhibitor utilized for the treatment of hepatitis B virus and human immunodeficiency virus infections; and is now one of the most widely used antiretroviral drug. However, tenofovir disoproxil fumarate can induce nephrotoxicity, which may be attributed to the interaction between such drug and the organic anion transporters (hOAT1, and OAT3) with consequent changes in levels of some parameters that may have a role in nephrotoxicity. Thiazide diuretics have high to intermediate potency of inhibition of OAT1s and OAT3; thus, it may possess nephroprotective effects. This study was designed to investigate whether hydrochlorthiazide has nephroprotective effects on tenofovir
... Show MoreBoth methotrexate and vitamin D3 are used in combination for the treatment of various diseases. The aim of this study is to highlight the effect of vitamin D3 on methotrexate-induced jejunum damage using biochemical and histopathological studies. Seven groups of both sexes of rats were selected and treated as follows: (Group I and Group II) : control 1,control 2 (I.P normal saline) daily for 14 and 21 days respectively ; (Group III and Group IV) :vitamin D3 groups (500 IU/rat/day) orally for 14 and 21 days, respectively;(Group V): once daily dose of methotrexate 20mg/kg, I.P injected for 4 days;(Group VI):vitamin D3 (500 IU/rat/day) once daily for 14 days and methotrexate (20 mg/kg I.P) injected only at day 10;.(Group VII) vit
... Show MoreThe electrical performance of bottom-gate/top source-drain contact for p-channel organic field-effect transistors (OFETs) using poly(3-hexylthiophene) (P3HT) as an active semiconductor layer with two different gate dielectric materials, Polyvinylpyrrolidone (PVP) and Hafnium oxide (HfO2), is investigated in this work. The output and transfer characteristics were studied for HfO2, PVP and HfO2/PVP as organic gate insulator layer. Both characteristics show a high drain current at the gate dielectric HfO2/PVP equal to -0.0031A and -0.0015A for output and transfer characteristics respectively, this can be attributed to the increasing of the dielectric capacitance. Transcondactance characteristics also studied for the three organic mater
... Show MoreAccurate estimation of permeability is essential for reliable reservoir characterization and simulation. However, core data are often limited due to their high cost and operational constraints, leading to significant uncertainty in uncored intervals. This study aims to reduce the dependence on core data for permeability estimation by integrating electrofacies derived from well logs and flow zone indicator analysis in the Mishrif Formation, Nasiriyah oil field. Electrofacies were generated using dynamic clustering based on the log data from 13 wells. This led to the identification of five electrofacies units that represent intervals with similar log responses, formed by merging 75 electrofacies, where flow zone indicators analysis id
... Show MoreThe behavior of AC conductivity (σac), loss tangent (tan δ), and relative permittivity (ε′) for composites of PVC-P/graphite electrode waste (GEW) was investigated, and a qualitative explanation was provided as a function of PVC-P weight fractions (0, 5, 10, 15, 20, and 25) wt. percent, temperature (30-90) °C, and frequency (100Hz-2MHz). The behaviors of the composites' ac. conductivity and impedance as a frequency function and temperature have been examined. The permittivity was shown to rise with increasing temperature (Tg). The relative permittivity increased as the GEW filler concentration increased and was highest in the low-frequency range; nevertheless decreased as the frequency increased.
Nanofluids, liquid suspensions of nanoparticles (Np), are an effective agent to alter the wettability of oil-wet reservoirs to water-wet thus promoting hydrocarbon recovery. It can also have an application to more efficient carbon storage. We present a series of contact angle (θ) investigations on initially oil-wet calcite surfaces to quantify the performance of hydrophilic silica nanoparticles for wettability alteration. These tests are conducted at typical in-situ high pressure (CO2), temperature and salinity conditions. A high pressure–temperature (P/T) optical cell with a regulated tilted surface was used to measure the advancing and receding contact angles at the desired conditions. The results showed that silica nanofluids can alte
... Show MoreTheoretical and experimental investigations have been carried out on developing laminar
combined free and forced convection heat transfer in a vertical concentric annulus with uniformly
heated outer cylinder (constant heat flux) and adiabatic inner cylinder for both aiding and opposing
flows. The theoretical investigation involved a mathematical modeling and numerical solution for
two dimensional, symmetric, simultaneously developing laminar air flows was achieved. The
governing equations of motion (continuity, momentum and energy) are solved by using implicit
finite difference method and the Gauss elimination technique. The theoretical work covers heat flux
range from (200 to 1500) W/m2, Re range from 400 to 2000 an