In the field of civil engineering, the adoption and use of Falling Weight Deflectometers (FWDs) is seen as a response to the ever changing and technology-driven world. Specifically, FWDs refer to devices that aid in evaluating the physical properties of a pavement. This paper has assessed the concepts of data processing, storage, and analysis via FWDs. The device has been found to play an important role in enabling the operators and field practitioners to understand vertical deflection responses upon subjecting pavements to impulse loads. In turn, the resultant data and its analysis outcomes lead to the backcalculation of the state of stiffness, with initial analyses of the deflection bowl occurring in conjunction with the measured or assumed layer thicknesses. In turn, outcomes from the backcalculation processes lead to the understanding of the nature of the strains, stresses, and moduli in the individual layers; besides layer thickness sensitivity, the determination of isotropic layer moduli, and establishing estimates in the subgrade CBR. Overall, impositions of elastic and low strain conditions foster the determination of resilient modulus and the analysis of unbound granular materials. Hence, FWD data processing, analysis, and storage gain significance in civil engineering because it informs the nature of designing new pavements and other rehabilitation design options.
The research aims to study the reliability of government institutions, including the audit directors, which are one of the most important oversight formations in the Ministry of Construction, Housing and Public Municipalities, on which the responsibility for comprehensive auditing of all the Ministry's (municipalities) formations falls on the Managing the Audit Program according to the specification (ISO 19011: 2018) to improve the audit performance which requires compliance with the application of the audit management system in accordance with the standard Specification (ISO 19011: 2018), depending on the methodology of the case study, and using of checklists, which were chosen ac
... Show MoreThis paper details the process of designing, analysing, manufacturing, and testing an integrated solid-state hydrogen storage system. Analysis is performed to optimise flow distribution and pressure drop through the channels, and experimental investigations compare the effects of profile shape on the overall power output from the fuel cell. The storing of hydrogen is given much attention in the selection of a storage medium, and the effect of a cooling system to reduce the recharging time of the hydrogen storage vessel. The PTFE seal performed excellently, holding pressure over 60 bar, despite requiring changing each time the cell is opened. The assembly of the vessel was simple and straightforward, and there was no indication of pressure
... Show MoreThe research aims to know the extent of the impact of the risks of foreign exchange centers represented in the risks of commitment, exchange rate changes and liquidity risks in audit procedures, and accordingly the research will provide an applied framework of knowledge that shows the relationship between the variables addressed, and the importance of the research lies in the light of its presentation of intellectual, cognitive and applied contributions On the risks of foreign exchange centers and audit procedures, the research community is represented in the banking sector. The sample included nine private commercial banks listed in the Iraqi Stock Exchange. The research relied on a time series consisting of four years that extended fro
... Show MoreThe primary goal of in-situ load testing is to evaluate the safety and performance of a structural system under particular loading conditions. Advancements in building techniques, analytical tools, and monitoring instruments are prompting the evaluation of the appropriate loading value, loading process, and examination criteria. The procedure for testing reinforced concrete (RC) structures on-site, as outlined in the ACI Building Code, involves conducting a 24-h load test and applying specific evaluation criteria. This article detailed a retrofitting project for an RC slab-beams system by utilizing carbon fiber-reinforced polymer (CFRP) sheets to strengthen the structure following a fire incident. The RC structure showed indicators of deter
... Show MoreCharacterization of the heterogonous reservoir is complex representation and evaluation of petrophysical properties and application of the relationships between porosity-permeability within the framework of hydraulic flow units is used to estimate permeability in un-cored wells. Techniques of flow unit or hydraulic flow unit (HFU) divided the reservoir into zones laterally and vertically which can be managed and control fluid flow within flow unit and considerably is entirely different with other flow units through reservoir. Each flow unit can be distinguished by applying the relationships of flow zone indicator (FZI) method. Supporting the relationship between porosity and permeability by using flow zone indictor is ca
... Show MoreCare and attention to the structure in the sixties of the last century replaced the mark, and if the structure of Ms. pampered in research and studies, it has become the mark is also a spoiled lady .. But the relationship between the structure and the mark was not a break and break, but the relationship of integration, His themes are structural analysis, and these are intellectual themes that can not be surpassed in contemporary research, especially since semiotics have emerged from the linguistic inflection.
We have tried to distinguish between text and speech, which is a daunting task, as it seems that whenever the difference between them is clear and clear, we come back to wonder whether the text is the same discourse, and is
... Show More