Preferred Language
Articles
/
dBc5C44BVTCNdQwCpTCt
Sawdust-Based Concrete Composite-Filled Steel Tube Beams: An Experimental and Analytical Investigation
...Show More Authors

Incorporating waste byproducts into concrete is an innovative and promising way to minimize the environmental impact of waste material while maintaining and/or improving concrete’s mechanical characteristics and strength. The proper application of sawdust as a pozzolan in the building industry remains a significant challenge. Consequently, this study conducted an experimental evaluation of sawdust as a fill material. In particular, sawdust as a fine aggregate in concrete offers a realistic structural and economical possibility for the construction of lightweight structural systems. Failure under four-point loads was investigated for six concrete-filled steel tube (CFST) specimens. The results indicated that recycled lightweight concrete performed similarly to conventional concrete when used as a filler material in composite steel tube beams. The structural effects of sawdust substitution on ultimate load and initial stiffness were less substantial than the relative changes in the material properties, and the ultimate capacity of the tested samples decreased moderately as the substitution percentage of sawdust increased. Moreover, the maximum load capacity was observed to decrease by 6.43–30.71% for sawdust replacement levels between 5% and 45.1% across all tested samples. Additionally, when using lightweight concrete with 5% sawdust, the moment value of the CFST sample was reduced by 6.4%. Notably, the sawdust CFST samples exhibited a flexural behavior that was relatively comparable to that of the standard CFST samples.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Feb 01 2023
Journal Name
Journal Of Engineering
Introduction and Investigation into Oil Well Logging Operations (Review)
...Show More Authors

ole in all sta Oil well logging, also known as wireline logging, is a method of collecting data from the well environment to determine subterranean physical properties and reservoir parameters. Measurements are collected against depth along the well's length, and many types of wire cabling tools depend on the physical property of interest. Well probes generally has a dynamic respon to changes in rock layers and fluid composition. These probes or well logs are legal documents that record the history of a well during the drilling stages until its completion. Well probes record the physical properties of the well, which must then be interpreted in petrographic terms to obtain the characteristics of the rocks and fluids associated with

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sat Aug 09 2025
Journal Name
Oxidation Communications
SYNTHESIS AND SPECTRAL CHARACTERISATION, MOLECULAR DOCKING, AND ANTIOXIDANT ACTIVITIES OF NOVEL METAL COMPLEXES AND THEIR NANOCOMPLEXES DERIVED FROM AN ISATIN-BASED SCHIFF BASE
...Show More Authors

Scopus (1)
Scopus
Publication Date
Thu Sep 30 2021
Journal Name
Journal Of Economics And Administrative Sciences
The Role of Continuous Improvement Strategy (Kaizen) in organizational innovation: An analytical research in the General Company of Electrical and Electronic Industries /The Ministry of Industry and Minerals
...Show More Authors

This paper aims at the fact that most organizations today suffer from a waste of time, effort, and cost, and they have difficulty in achieving the best performance situations and compete strongly. The researcher distributed 108 questionnaires as a statistical analyzable sample society where the sample intentionally consists of general managers, department head, and division head. The questionnaire was formulated according to the Likert scale. The use of personal interviews and observations are additional tools for data collection and a number of statistical methods is used for data analysis such as simple regression and correlation coefficient (Pearson). One of the most prominent conclusions is that the company has adequate and c

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 30 2020
Journal Name
Modern Sport
An analytical study of the vitality of the conscience of the senior leaderships in the boards of colleges and departments of physical education and sports science in Baghdad
...Show More Authors

The problem of research lies in answering some of the question: What is the reality of (vital conscience) in some colleges and departments of physical education and sports science in Baghdad from the viewpoint of the teachers? And The aim of the research is to prepare a scale (the vitality of the conscience) and learn about its reality in colleges and departments of physical education and sports science in Baghdad from the viewpoint of teachers and The researcher relied on the descriptive method in the survey method and the relationships related to the nature of the research problem and The sample of the research was senior administrators teaching some colleges and departments of physical education and sports science in Baghdad , Th

... Show More
Preview PDF
Crossref
Publication Date
Mon Mar 17 2014
Journal Name
Arabian Journal For Science And Engineering
Thermal and Hydraulic Characteristics of a Novel Helical Coiled Tube Used as a Heat Exchanger
...Show More Authors

In the present work, the thermo-fluid characteristics of a heat exchanger formed of helical coiled tubes immersed in cold water are investigated experimentally. Two types of helical coiled tube are tested, a conventional vertical single helical coiled tube and a new triple vertical helical coiled tube in parallel connection called as meshed coils. The effect of hot water flow rates inside the tubes (ranges from 2.67 to 7.08 l/min), and its inlet temperatures (namely 50, 60, 70 and 80 °C) are investigated. The experimental results show that increasing the flow rate inside the meshed coils leads to decrease the temperature difference between inlet and outlet. An enhancement of heat transfer for meshed coils compared to single coil has been n

... Show More
View Publication
Scopus (13)
Crossref (10)
Scopus Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
SOLAR WATER HEATER WITH SHELL AND HELICAL COILED TUBE HEAT EXCHANGER AS A STORAGE TANK
...Show More Authors

In this work an experimental study is performed to evaluate the thermal performance
of locally made closed loop solar hot water system using a shell and helical coiled tube
heat exchanger as a storage tank. Several measurements are taken include inlet and outlet
temperatures of both collectors and supply water and temperature distribution within the
storage tank. This is beside the water flow rate in both collectors and load cycle. The
main parameters of the system are obtained.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
...Show More Authors

This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Journal Of Energy Storage
Accelerated charging dynamics in shell-and-multi-tube latent heat storage systems for building applications
...Show More Authors

View Publication
Scopus (24)
Crossref (22)
Scopus Crossref
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Heat Transfer Analysis of Conventional Round Tube and Microchannel Condensers in Automotive Air Conditioning System
...Show More Authors

In this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Journal Of Energy Storage
Multiple-segment metal foam application in the shell-and-tube PCM thermal energy storage system
...Show More Authors

View Publication
Scopus (171)
Crossref (143)
Scopus Clarivate Crossref