The technology of subsurface soil water retention (SWRT) uses a polyethylene trough that is fixed under the root zone of the plant. It is a modern technology to increase the values of water use efficiency, plant productivity and saving irrigation water by applying as little irrigation water as possible. This study work aims at improving the crop yield and water use efficiency of a cucumber plant with less applied irrigation water by installing membrane trough below the soil surface. The field experiment was conducted in the Hawr Rajab District of Baghdad Governorate in Winter 2018 for testing various trickle irrigation systems. Two agricultural treatment plots were utilized in a greenhouse for the comparison. Plot T1 has used a subsurface trickle irrigation together with membrane trough. Plot T2 has used only surface trickle irrigation system without using SWRT. The total area of the plots T1and T2 was 13.2 m2 and 6.66 m2, respectively. The obtained results of the study confirmed that the plot T1 satisfies values greater than plot T2 in terms of crop yield, field water use efficiency and in saving the applied irrigation water. The increase rate of field water use efficiency and crop yield in plot T1 compared with plot T2 was 103 %, and 24 %, respectively. Additionally, the increase rate in saving the applied irrigation water in plot T1 comparing with plot T2 was 64 %. The installation of the membrane trough below the plant’s root zone together with subsurface trickle irrigation system assisted in keeping the water, nutrients, and fertilizers during the root zone profile, improving the field water use efficiency and then the parameter of water productivity.
The present study deals with the assessment of water Quality Index to theAl-
Khadhimiya Groundwater city, by collection groundwater from 13wells during four
seasons, subjecting the samples to a comprehensive physicochemical analysis. The
13 parameters have been considered: pH, total hardness, calcium, magnesium,
turbidity, nitrate, electrical conductivity, total dissolved solid, Sulfate, Chloride,
zinc, manganic, and iron, that are used for calculating the WQI. From the result
shown, the most groundwater quality lies in Unfit for human drinking purpose. The
wells (1 and 11) and wells (3 and 10) were a bad water quality for drinking purpose
since they lie in poor and in very poor respectively according to the WQI.
Phytoplankton, as one of the most important primary producers in aquatic ecosystems, has been widely used to indicate the health of ecosystems. Nine physico-chemical parameters of water, as well as the phytoplankton community, of Al-Chibayish marsh were studied. Samples were collected from four sites and analyzed every two months from January to October 2019.
Seasonal variations in physical and chemical properties were observed at all sites during the study period. The results indicated that 154 species of phytoplankton were recorded. The highest percentage of species was recorded to be 64.28% for Bacillariophyceae (diatoms) (Centrales 3.24% and Pennales 61.03%), followed by Chlorophyceae (16.23%), Cyanophyceae
... Show MoreThis research studies the influence of water source on the compressive strength of high strength concrete. Four types of water source were adopted in both mixing and curing process these are river, tap, well and drainage water (all from Iraq-Diyala governorate). Chemical analysis was carried out for all types of the used water including (pH, total dissolved solids (TDS), Turbidity, chloride, total suspended solid (TSS), and sulfates). Depending on the chemical analysis results, it was found that for all adopted sources the chemical compositions was within the ASTM C 1602/C 1602M-04 limits and can be satisfactorily used in concrete mixtures. Mixture of high strength concrete for compressive strength of (60 MPa) was designed and checked using
... Show MoreThis research involves the application of spectral indices and GIS techniques coupled with the Analytic Hierarchy Process, to assess Baglia site, eastern Missan, as a water harvesting potential site. The AHP and pairwise comparison have been used through select four criteria including TWI, TRI, MNDWI, and NDSI, which were deemed as impact factors for this study. All these criteria have been weighted according to their significance in the water harvesting system. The findings of the AHP analysis method explained that the WH potential zones in Baglia site were divided into three zones, namely, high, medium, and low suitability. The findings demonstrate that Bglia site, where the highly appropriate zone is located in the deep v
... Show MoreThe corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were
... Show MoreGroundwater is very important for different uses in the present study area which represents Jisr Diyala, located in southeastern Baghdad and covered with quaternary deposits which include the shallow aquifer in the area. Groundwater and surface water were investigated to determine their suitable uses. The main ion concentrations of the wet period seemed to be lower than those in the dry period. According to TDS values, the water is classified as brackish to salty with a high degree of hardness. Most of water samples were of NaCl type due to pollution with sewage water and rock-water interaction. The results show that the water of the study area is suitable for livestock and irrigation purposes only.
The goal of current research to know the according of scientific values in the curriculum of chemistry sixth - grade science To achieve this goal wasa to build aalistaofa scientifica values toa be included in the curriculum of chemistry sixth - grade science after seeing a group of literature and previous studies, the list presented to a group of arbitrators and specialists in educational and psychological sciences and methods of teaching science, and curricula and teaching methods , Arbitrators and specialists have expressed their views and comments on the tool, and that the list was formed in final form (9) values Head of scientific includes ( 35) sub - value, then the researcher analyzed the chemistry curriculum for sixth grade Scient
... Show MoreContamination of surface and groundwater with excessive concentrations of fluoride is of significant health hazard. Adsorption of fluoride onto waste materials of no economic value could be a potential approach for the treatment of fluoride-bearing water. This experimental and modeling study was devoted to investigate for the first the fluoride removal using unmodified waste granular brick (WGB) in a fixed bed running in continuous mode. Characterization of WGB was carried out by FT-IR, SEM, and EDX analysis. The batch mode experiments showed that they were affected by several parameters including contact time, initial pH, and sorbent dosage. The best values of these parameters that provided maximum removal percent (82%) with the in
... Show MoreAn experimental study was conducted on pressure drop of water flow through vertical cylindrical packed beds in turbulent region and the influence of the operating parameters on its behavior. The bed packing was made of spherical and non-spherical particles (spheres, Rasching rings and intalox saddle) with aspect ratio range 3.46 D/dp 8.486 obtaining bed porosities 0.396 0.84 and Reynolds number 1217 21758. The system is consisted of 5 cm inside diameter Perspex column, 50 cm long; distilled water was pumped through the bed with flow rate 875, 1000, 1125, 1250,1375 and 1500 l/h and inlet water temperature 20, 30, 40 and 50 ˚C. The packed bed system was monitored by using LabVIEW program, were the result
... Show More