Preferred Language
Articles
/
cxcZ444BVTCNdQwCnln4
Subsurface Water Retention a Technology for Increasing the Field Use Efficiency and Water Saving Values of Cucumber Plant
...Show More Authors

The technology of subsurface soil water retention (SWRT) uses a polyethylene trough that is fixed under the root zone of the plant. It is a modern technology to increase the values of water use efficiency, plant productivity and saving irrigation water by applying as little irrigation water as possible. This study work aims at improving the crop yield and water use efficiency of a cucumber plant with less applied irrigation water by installing membrane trough below the soil surface. The field experiment was conducted in the Hawr Rajab District of Baghdad Governorate in Winter 2018 for testing various trickle irrigation systems. Two agricultural treatment plots were utilized in a greenhouse for the comparison. Plot T1 has used a subsurface trickle irrigation together with membrane trough. Plot T2 has used only surface trickle irrigation system without using SWRT. The total area of the plots T1and T2 was 13.2 m2 and 6.66 m2, respectively. The obtained results of the study confirmed that the plot T1 satisfies values greater than plot T2 in terms of crop yield, field water use efficiency and in saving the applied irrigation water. The increase rate of field water use efficiency and crop yield in plot T1 compared with plot T2 was 103 %, and 24 %, respectively. Additionally, the increase rate in saving the applied irrigation water in plot T1 comparing with plot T2 was 64 %. The installation of the membrane trough below the plant’s root zone together with subsurface trickle irrigation system assisted in keeping the water, nutrients, and fertilizers during the root zone profile, improving the field water use efficiency and then the parameter of water productivity.

Crossref
View Publication
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Mathematical Model for BOD in Waste Water Discharges from Al Dora Refinery in Baghdad
...Show More Authors

This research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated that th

... Show More
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering
Mathematical Model for BOD in Waste Water Discharges from Al Dora Refinery in Baghdad
...Show More Authors

This research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there
is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
A study of Irrigation Water Pollution By Some Heavy Metals in Baghdad Governorate
...Show More Authors
Abstract<p>A study of irrigation water was conducted Baghdad city to find out extent of its pollution by some heavy metals (Pb, Cd, Ni, Co, CU, Cr, Zn and Fe). Water samples were collected randomly from different sources (river, well and stream). Results showed that the concentration of studied heavy metals were as follows: Lead between 0.43-11.75 mg L<sup>-1</sup>, Cadmium between 0.01-0.95 mg L<sup>-1</sup>, Nickel between 0.008-0.46 mg L<sup>-1</sup>, Cobalt between Nil - 0.185 mg L<sup>-1</sup>, Copper is between 0.326 - 1.58 mg L<sup>-1</sup>, Chromium is between Nil-0.068 mg L<sup>-1</sup>, Zinc 0.398-1.182 mg L<sup>-1</sup>, as for Iro</p> ... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Heliyon
Removal of amoxicillin from contaminated water using modified bentonite as a reactive material
...Show More Authors

This study concerns the removal of a trihydrate antibiotic (Amoxicillin) from synthetically contaminated water by adsorption on modified bentonite. The bentonite was modified using hexadecyl trimethyl ammonium bromide (HTAB), which turned it from a hydrophilic to a hydrophobic material. The effects of different parameters were studied in batch experiments. These parameters were contact time, solution pH, agitation speed, initial concentration (C0) of the contaminant, and adsorbent dosage. Maximum removal of amoxicillin (93 %) was achieved at contact time = 240 min, pH = 10, agitation speed = 200 rpm, initial concentration = 30 ppm, and adsorbent dosage = 3 g bentonite per 1L of pollutant solution. The characterization of the adsorbent, modi

... Show More
View Publication
Scopus (11)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Engineering
Evaluation of Fatigue Behavior of Epoxy Coatings used for Potable Water Storage Tanks
...Show More Authors

In this paper, three types of epoxy-based coatings (Polyamide, pure Polyamine, and Polyamine reinforced by glass-flake) used as a lining for potable water tanks were studied using experimental and finite element methods. Tensile, impact, and fatigue tests were conducted on uncoated and coated AISI 316 stainless steel. The test results show that the applied epoxy based coating improves the mechanical properties, increases of fatigue crack resistance, and enhance the dynamic fracture toughness. The fatigue crack propagation is influenced by the compositions of epoxy coating, and the glass-flake improves the coating resistance to fatigue crack propagation compared to other types.

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Dec 03 2024
Journal Name
International Journal Of Cognitive Neuroscience And Psychology
EXAMINATION OF THE USE OF PICTURE CARD TECHNOLOGY TO HELP ELEMENTARY SCHOOL STUDENTS DEVELOP THEIR BASKETBALL SKILLS
...Show More Authors

Publication Date
Sat Dec 16 2023
Journal Name
2023 14th International Renewable Energy Congress (irec)
Utilizing the Controlled Hydropower System to Harness the Collected Water in Drainage System for Power Generation
...Show More Authors

The variety of clean energy sources has risen, involving many resources, although their fundamental principles remain consistent in terms of energy generation and pollution reduction. The using of hydropower system for energy production also has a dynamic impact in which it utilizes to harness the water for the purpose of energy production. As it is important to overcome the problem of accidents in the highway and rural areas in the case of server rainfall and flood by implementation a smart system that used for energy production. This paper aims to develop a controlled hydropower system installed in the drainage sinks allocated in highway roads used for producing. The proposed system consists of storage unit represented by pipes used for t

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Evaluation The Performance efficiency of the general company for lather Industries (a practical study)
...Show More Authors

The performa of evaluation process is a process that should be carried out by all industrial management in order to stand on aspects of development or underdevelopment of the various departments and activities in its industrial project for the purpose of identifying obstacles and find out the causes and then avoid them quickly. And intended to rectify the performance evaluation of the  activities of  industrial project  or economic union by measuring the results achieved within a specific operational process and compare it to what is already targeted, and often the time for comparison of one year.

The process of performance evaluation depends upon several criteria and indicators within the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Sep 19 2017
Journal Name
International Journal Of Science And Research
Volumetric Change of Concrete Containing Water Absorption Polymer Balls
...Show More Authors

Polymers have the ability to extract water after they have been added to the mortar or concrete mixture. They provide the absorbed water during hydration functioning as internal water source. Absorption polymers can absorb up to hundred times of their own weight of pure water.This research deals with the use of water absorption polymer balls in concrete and study the volumetric change of these mixes and compared the results with reference mix (without polymers). Samples were cured both in air and in water for the mixes to compare results which show that samples in air behave for expansion while sample in water acted for shrinkage.

Publication Date
Thu Apr 20 2023
Journal Name
Maaen Journal For Medical Sciences
Evaluation of heated cure acrylic immersed in ozonated water
...Show More Authors

Background: Denture cleansing is an important step that can prevent the spread of infection and improve a patient's health, the durability of the dentures, and the overall quality of life; therefore, it is necessary to choose a suitable cleanser that, in addition to being effective, does not have an unfavorable effect on the qualities of the denture base resin itself when used for an extended period. Aim: This research aims to assess the effects of ozonated water on the surface roughness and hardness of heat-cured acrylic resin by immersion technique. Materials: Sixty bars shapemade of heat-cured acrylicweremanufactured.Thirty samples for every test, including: (surface hardness and surface roughness). Then, these samples were divided into

... Show More
View Publication
Crossref