Thirteen morphometric characters of catfish
This research involves the preparation of new ligands 1,1,2,2- tetrakis (sodium acetate thio)ethylene(L1) and 1,1,2- tris(sodiumacetatethio) ethylene(L2), through the reaction of disodium thioglycolate) with tetra chloro ethylene or tri chloro ethylene in (1:4) or (1:3) moler ratio . Homodinucliar complexes of general formlu [M2(L1)] and [M2(L2)ClH2O] , when M= Co(II), Ni(II), Cu (II) and Zn(II) also mono nuclear complexes of general formula [M(L2)] . The prepared complexes were characterized using spectral method (UV/Visible/ IR) , metal content analysis , magnetic and atomic measurements . The spectral and magnetic measurement indicats that some complexes have tetrahedral or square planar complexes environtment .
Objective: The aim of this study is to detect the effect of continuous exposure to Sodium Nitrite on 8-oxoguanine
DNA glycosylase (OGG1) gene which responsible on DNA repairs. DNA repair play a major role in maintaining
genomic stability when DNA exposure to damage. Genomic stability is very important for keeping body cells
healthy and to prevent many types of tumor development. Many genes are responsible for this job; one of them is
OGG1 gene.
Methodology: In current study two groups of mice were chronically exposed to sodium nitrite for six months and
eighteen months while third group was used as a control. Then sizes of OGG1 were estimated.
Results: The results exhibited in the unexposed (control) mice had two dif
The present study included the effect of acute exposure of different concentrations of sodium chloride on the Zooplankton Crustacean Daphnia pulex which belong to the order Cladocera. The lethal concentrations killing 50% of the population (LC50) after 24hrs and 48hrs were 2.95‰ and 2.63‰ respectively While lethal concentrations killing 100% of the population (LC100) and non lethal concentrations (LC0) were 6‰ and 0.5‰ after 24hrs of exposure to NaCl. The acute exposure of the Crustacean Daphnia pulex showed increasing in mortality percentages with increasing the concentrations and exposure time
The solution gas-oil ratio is an important measurement in reservoir engineering calculations. The correlations are used when experimental PVT data from particular field are missing. Additional advantages of the correlations are saving of cost and time.
This paper proposes a correlation to calculate the solution gas -oil ratio at pressures below bubble point pressure. It was obtained by multiple linear regression analysis of PVT data collected from many Iraqi fields.
In this study, the solution gas-oil ratio was taken as a function of bubble point pressure, stock tank oil gravity, reservoir pressure, reservoir temperature and relative gas density.
The construction of the new correlation is depending on thirty seven PVT reports th
Background:Nocturnal Enuresis is a common problem affecting 20% of five years old children and up to 2% of adolescent and young adult. Although it is a self limiting benign condition, it has social and psychological impact on the child and his family. Many pathophysiological theories had been suggested, but none is confirmed. Hypercalciuria has been suggested to be associated with higher incidence of nocturnal enuresis. Objectives:The aim of our study to test the value of Ca/Cr ratio, on random urine sample, in diagnosing hypercalciuria in enuretic children. Type of study: Cross sectional study.Methods:Forty four enuretic children were enrolled in this study and forty five children without nocturnal enuresis were taken as control group.
... Show MoreAxial spondyloarthritis (axSpA) is a chronic rheumatic inflammatory disease affecting mainly the spine and sacroiliac joints. Since the copper-to-zinc ratio (Cu/Zn) indicates an inflammatory response, the change in ratio is expected to correlate with axSpA. This study compared levels of Cu/Zn in the serum of axSpA patients. Serum samples were obtained from 53 patients with axSpA divided according to biological treatment into cohorts A and B, and 28 healthy control as cohort C. Serum levels of Cu and Zn were determined first by a fully automated chemistry analyzer TC-Matrix Plus, then the ratio was obtained. The elevated serum Cu concentration means of cohort B (189.32 ± 13.808 µg/dL) compared to cohort A (168.85 ± 7.244 µg/dL) a
... Show MoreBackground: Undergraduate dental students are more susceptible to situations of stress that affected quality of sleep, such profiles of stress may result in sleep bruxism and/or awake bruxism, parafunctions that can affect oral and general health. The aim of the study was to evaluate the association of sleep bruxism, awake bruxism and sleep quality among dental students. Materials and methods: A cross-sectional study was performed including 260 Iraqi dental students from university of Baghdad aged from 20to25years old. Students enrolled in the third and fifth class participated in the study. The Pittsburgh Sleep Questionnaire Index (PSQI) was used for data collection. The PSQI was distributed during lecture classes. Sleep bruxism and awake
... Show MoreFrom September 2002 to August 2003 monthly samples of fish were collected from two stations at the area of study. The results of the present study showed that the sex-ratio (male: female) was 1:0.95. Sexual maturity was reached by all fishes above 28 cm in total length , the smallest mature male was 21.3 cm in total length and body weight 164 gm. While the smallest mature female was 21.5 cm in T.L. and body weight 155 gm. The mature male and female were in the second year of their ages. The breeding season extended from the end of February until the end of June and another season started from Se
... Show MoreA chemometric method, partial least squares regression (PLS) was applied for the simultaneous determination of piroxicam (PIR), naproxen (NAP), diclofenac sodium (DIC), and mefenamic acid (MEF) in synthetic mixtures and commercial formulations. The proposed method is based on the use of spectrophotometric data coupled with PLS multivariate calibration. The Spectra of drugs were recorded at concentrations in the linear range of 1.0 - 10 μg mL-1 for NAP and from 1.0 - 20 μg mL-1 for PIR, DIC, and MEF. 34 sets of mixtures were used for calibration and 10 sets of mixtures were used for validation in the wavelength range of 200 to 400 nm with the wavelength interval λ = 1 nm in methanol. This method has been used successfully to quant
... Show More