Preferred Language
Articles
/
cvrnt5kBMF18lwyZCs3Q
A comparative study between tongue thickness measured by ultrasonography and thyromental distance in anticipation of difficult intubation
...Show More Authors

Background & objective: Difficult intubation remains a risk for patients undergoing general anesthesia (GA) or mechanical ventilation in an intensive care unit (ICU). Macroglossia is a known factor for difficult intubation. But it is not routine to assess the tongue size to predict difficult intubation. Studies are found deficient in comparing usefulness of measuring thyromental distance and the tongue thickness (TT) measured by ultrasonography to estimate difficult intubation. We compared tongue thickness measured by ultrasonography and thyromental distance as a means to anticipate difficult intubation. Methodology: A convenient sample of 60 patients; 32 males and 28 females, who were undergoing elective surgery with GA were included. Thyro-mental distance (TMD), along with tongue thickness (TT) were measured consecutively in each patient in a transitional room. After induction of GA, Cormack Lehane (CL) score was assessed for all patients to detect difficult intubation. Results: Thyro-mental distance was significantly reduced in patients with difficult intubation, while the reverse was in the measurement of tongue thickness; where patients with difficult intubation had significantly a greater TT than those with no difficult intubation. TT measurement had significantly higher sensitivity and specificity (38%, and 96% respectively; P = 0.002) than thyro-mental distance in the detection of difficult intubation. Conclusion: In this study we demonstrated that there was statistically significant inverse relationship of thyro-mental distance on CL, and statistically significant direct relationship of tongue thickness on CL. The results showed that tongue thickness was more effective to detect difficult intubation. Abbreviations: CL - Cormack Lehane; TMD - Thyro-mental distance; TT - Tongue thickness; Keywords: Tongue Thickness; Thyromental Distance; Difficult Intubation Citation: Kadhim AB, Hamid GR. A comparative study between tongue thickness measured by ultrasonography and thyromental distance in anticipation of difficult intubation. Anaesth. pain intensive care 2024;28(3):431−435; DOI: 10.35975/apic.v28i3.2465 Received: March 16, 2024; Reviewed: March 29, 2024; Accepted: March 31, 2024      

Clarivate Crossref
View Publication
Publication Date
Mon Oct 06 2025
Journal Name
المستودع الرقمي للاطاريح
نجاح منظمات الاعمال على وفق التوجه الريادي لتكنولوجيا المعلومات بحث ميداني لعينة من المصارف العراقية الخاصة == The Success of Business Organizations According To The Entrepreneurial Orientation For Information Technology An Field Research At Iraqi Private Banks
...Show More Authors

المستودع الرقمي العراقي. مركز المعلومات الرقمية التابع لمكتبة العتبة العباسية المقدسة

View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Advances In Materials Physics And Chemistry
The Role of Cooling Condition on the Superconducting Properties of Tl<sub>2-x</sub>Hg<sub>x</sub>Sr<sub>2</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10+δ</sub> System
...Show More Authors

View Publication
Crossref
Publication Date
Tue Jul 20 2021
Journal Name
Materials Science Forum
Red Laser Irradiation Effect on the Structural Properties of MawsoniteCu<sub>6</sub>Fe<sub>2</sub>SnS<sub>8</sub> [CFTS] Thin Films Deposited via Semi-Computerized Spray Pyrolysis Technique
...Show More Authors

The existing investigation explains the consequence of irradiation of violet laser on the structure properties of MawsoniteCu6Fe2SnS8 [CFTS] thin films. The film was equipped by the utilization of semi-computerized spray pyrolysis technique (SCSPT), it is the first time that this technique is used in the preparation and irradiation using a laser. when the received films were processed by continuous red laser (700 nm) with power (>1000mW) for different laser irradiation time using different number of times a laser scan (0, 6, 9, 12, 15 and 18 times) with total irradiation time (0,30,45,60,75,90 min) respectively at room temperature.. The XRD diffraction gave polycrysta

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Materials Science Forum
The Effect of Gamma Radiation on the Manufactured HgBa<sub>2</sub>Ca<sub>2</sub>Cu<sub>2.4</sub>Ag<sub>0.6</sub>O<sub>8+δ</sub> Compound
...Show More Authors

In this article four samples of HgBa2Ca2Cu2.4Ag0.6O8+δ were prepared and irradiated with different doses of gamma radiation 6, 8 and 10 Mrad. The effects of gamma irradiation on structure of HgBa2Ca2Cu2.4Ag0.6O8+δ samples were characterized using X-ray diffraction. It was concluded that there effect on structure by gamma irradiation. Scherrer, crystallization, and Williamson equations were applied based on the X-ray diffraction diagram and for all gamma doses, to calculate crystal size, strain, and degree of crystallinity. I

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Crossref