Theoretical and experimental investigation of a heat pipe heat exchanger for energy recovery of exhaust air
...Show More Authors

Heat pipes and two‐phase thermosyphon systems are passive heat transfer systems that employ a two‐phase cycle of a working fluid within a completely sealed system. Consequently, heat exchangers based on heat pipes have low thermal resistance and high effective thermal conductivity, which can reach up to the order of (105 W/(m K)). In energy recovery systems where the two streams should be unmixed, such as airconditioning systems of biological laboratories and operating rooms in hospitals, heat pipe heat exchangers (HPHEs) are recommended. In this study, an experimental and theoretical study was carried out on the thermal performance of an air‐to‐air HPHE filled with two refrigerants as working fluids, R22 and R407c. The heat pipe heat exchanger used was composed of two rows of copper heat pipes in a staggered manner, with 11 pipes per row. Tests were conducted at different airflow rates of 0.14, 0.18, and 0.22m3/h, evaporator inlet‐air temperatures of 40, 44, and 50°C, filling ratios of 45%, 70%, and 100%, and ratios of heat capacity rate of the evaporator to condenser sections (Ce/Cc) of 1 and 1.5. For HPHE's steady‐state operation, a mathematical model for heat‐transfer performance was set and solved using MATLAB. Results illustrated that the heat transfer rate was in direct proportion with the evaporator inlet‐air temperature and flow rate. The highest HPHE's effectiveness was obtained at a 100% filling ratio and (Ce/Cc) of 1.5. The predicted and experimental values of condenser outletair temperature were in good agreement, with a maximum difference of 3%. HPHE's effectiveness was found to increase with the increase in evaporator inletair temperature and number of transfer units (NTU) and with the decrease in airflow rate, up to 33% and 20% for refrigerants R22 and R407c, respectively. Refrigerant R22 was the superior of the two refrigerants investigated.

Scopus Clarivate Crossref
Publication Date
Mon Apr 17 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Simulation Expirment for Proofing the Theoretical Assumption of Time Complexity for Binary Search Tree
...Show More Authors

      It is frequently asserted that an advantage of a binary search tree implementation of a set over linked list implementation is that for reasonably well balanced binary search trees the average search time (to discover whether or not a particular element is present in the set) is O(log N) to the base 2 where N is the number of element in the set (the size of the tree).  This paper presents an experiment for measuring and comparing the obtained binary search tree time with the expected time (theoretical), this experiment proved the correctness of the hypothesis, the experiment is carried out using a program in turbo Pascal with recursion technique implementation and a statistical method  to prove th

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Advanced Powder Technology
Modification of FAU zeolite as an active heterogeneous catalyst for biodiesel production and theoretical considerations for kinetic modeling
...Show More Authors

View Publication
Scopus (25)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Experimental study of some shielding parameters for composite shields
...Show More Authors

View Publication
Scopus (8)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Water flow velocity and oxide film formation effect on copper pipe corrosion
...Show More Authors

An overall mathematical model for copper pipe corrosion in flowing water was derived based on mass transfer fundamentals where we introduced the effects of boundary layer velocity, bulk flow velocity and the surface oxide protective film on the corrosion rate. A set of experiments were conducted in a straight 10mm diameter copper pipe, flow of water include six velocities of maximum value 7.33m/sec at 200C and 350C. The good agreement between the calculated and experimental corrosion rate values were achieved , the agreement reached 92% .

View Publication Preview PDF
Crossref
Publication Date
Tue Jun 05 2018
Journal Name
Journal Of Molecular Structure
Synthesis, characterization, experimental and theoretical structure of novel Dichloro(bis{2-[1-(4-methoxyphenyl)-1H-1,2,3-triazol-4-ylkN3] pyridine-kN})metal(II) compounds, metal ¼ Mn, Co and Ni
...Show More Authors

The syntheses, characterizations and structures of three novel dichloro(bis{2-[1-(4-methoxyphenyl)-1H-1,2,3-triazol-4-yl-κN3]pyridine-κN})metal(II), [M(L)2Cl2], complexes (metal = Mn, Co and Ni) are presented. In the solid state the molecules are arranged in infinite hydrogen-bonded 3D supramolecular structures, further stabilized by weak intermolecular π…π interactions. The DFT results for all the different spin states and isomers of dichloro(bis{2-[1-phenyl-1H-1,2,3-triazol-4-yl-κN3]pyridine-κN})metal(II) complexes, [M(L1)2Cl2], support experimental measurements, namely that (i) d5 [Mn(L1)2Cl2] is high spin with S = 5/2; (ii) d7 [Co(L1)2Cl2] has a spin state of S = 3/2, (iii) d8 [Ni(L1)2Cl2] has a spin state of S =

... Show More
Preview PDF
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Performance evolution of a hybrid thermal solar air conditioning system and compare it with a traditional system according to Iraq weather
...Show More Authors

In a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 06 2015
Journal Name
Baghdad Science Journal
Energy Calculation for Excited Lithium Atom in Position Space
...Show More Authors

The energy expectation values for Li and Li-like ions ( , and ) have been calculated and examined within the ground state and the excited state in position space. The partitioning technique of Hartree-Fock (H-F) has been used for existing wave functions.

View Publication Preview PDF
Crossref
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Theoretical Study of New Derivative of Cefotaxime-Amic Acid as a Corrosion Inhibitor
...Show More Authors

PM3 and DFT quantum mechanical calculations were employed to give further
insight into the inhibition efficiency of the newly prepared cefotaxime amic acid
derivative. The calculated physical properties and quantum chemical parameters
correlated to the inhibition efficiency such as EHOMO (highest occupied molecular
orbital energy), ELUMO (lowest unoccupied molecular orbital energy), the energy gap
(ΔE(HOMO-LUMO)), hardness (η), softness (S), dipole moment (μ), electron affinity
(EA), ionization potential (IE) and active site absorption..…etc., all studied and
discussed at equilibrium geometry in the gas phase and at its right symmetry (C1).
Experimentally the newly prepared cefotaxime derivative could be abso

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Energy Reports
Effect of solvents on performance of Alq3/ZnO solar cells: A theoretical approach
...Show More Authors

Successfully, theoretical equations were established to study the effect of solvent polarities on the electron current density, fill factor and efficiencies of Tris (8-hydroxy) quinoline aluminum (Alq3)/ ZnO solar cells. Three different solvents studied in this theoretical works, namely 1-propanol, ethanol and acetonitrile. The quantum model of transition energy in donor–acceptor system was used to derive a current formula. After that, it has been used to calculate the fill factor and the efficiency of the solar cell. The calculations indicated that the efficiency of the solar cell is influenced by the polarity of solvents. The best performance was for the solar cell based on acetonitrile as a solvent with electron current density of (5.0

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Radiation Research And Applied Sciences
Theoretical formula for the cosmic-ray muon attenuation coefficients of Pb, Cu, Zn, and Al
...Show More Authors

View Publication
Crossref (1)
Clarivate Crossref