In recent years, there has been a rise in interest in the study of antibiotic occurrence in the aquatic environment due to the negative consequences of prolonged exposure and the potential for bacterial antibiotic resistance. Most antibiotic residues from treated wastewater end up in the aquatic environment as they are not eliminated in facilities that treat wastewater. Antibiotics must be identified in influent and effluent wastewater using reliable analytical techniques for several reasons. Firstly, monitoring antibiotic presence in aquatic environments. Secondly, assessing environmental risks, computing wastewater treatment plant removal efficiencies, and estimating antibiotic consumption. Therefore, this work aims to provide an overview of existing approaches for determining antibiotics in complicated matrices including wastewater. Because it is currently the most effective and often used analytical method for determining antibiotic residue, liquid chromatography linked to tandem mass spectrometry was chosen.
This paper introduces a novel nonparametric hybrid cyber-intelligence-based statistical process control and anomaly detection framework in time series data. It is developed to overcome the shortcomings of the classical control schemes in dealing with complex, abnormal, and noisy input data, especially when it is autocorrelated. The proposed methodology combines three technical pillars: First, it utilizes a bidirectional long-short-term memory architecture (Bi-LSTM) to capture long-term time dependency and learn nonlinear patterns, leaving only true deviations as residuals that remove trends and noises from the market. Second, it adopts the Golden Eagle Optimizer (GEO) algorithm for optimal parameter selection. This intelligent algor
... Show MoreThe aim of this study was to investigate antibiotic amoxicillin removal from synthetic pharmaceutical wastewater. Titanium dioxide (TiO2) was used in photocatalysis treatment method under natural solar irradiation in a tubular reactor. The photocatalytic removal efficiency was evaluated by the reduction in amoxicillin concentration. The effects of antibiotics concentration, TiO2 dose, irradiation time and the effect of pH were studied. The optimum conditions were found to be irradiation time 5 hr, catalyst dosage 0.6 g/L, flow rate 1 L/min and pH 5. The photocatalytic treatment was able to destruct the amoxicillin in 5 hr and induced an amoxicillin reduction of about 10% with 141.8 kJ/L accumulate
... Show MoreAbstract The current research aimed at analyzing the content of the chemistry book for the third intermediate grade according to environmental ethics. The two researchers adopted the descriptive analytical approach, as the research community and its sample of the chemistry book for the third intermediate grade, approved by the Iraqi Ministry of Education for the academic year (2021-2022). The two researchers built a list ( +- standard) of environmental ethics, which included three main areas ( ethics of protecting the environment from pollution, ethics of protecting environmental resources from consumption (rationalization of consumption) and protecting living organisms, and the ethics of environmental literacy), and then derived from it (
... Show MoreThe skin temperature of the earth’s surface is referred to as the Land Surface Temperature (LST). the availability of long-term and high-quality temperature records is important for various uses that affect people’s lives and livelihoods. Much valid information was provided to this research from remote sensing technology by using Landsat 8 (L8) imagery to estimate LST for Al-Ahdab oil field in Wasit city in Iraq. The aim of this research is to analyze LST variations based on Landsat 8 data for 2022 (January, April, July, and October). ArcMap 10.8 was used to estimate LST results. The results values ranged from (about 10 C in January to about 46 C in July). The results show that LS
In this paper, previous studies about Fuzzy regression had been presented. The fuzzy regression is a generalization of the traditional regression model that formulates a fuzzy environment's relationship to independent and dependent variables. All this can be introduced by non-parametric model, as well as a semi-parametric model. Moreover, results obtained from the previous studies and their conclusions were put forward in this context. So, we suggest a novel method of estimation via new weights instead of the old weights and introduce
Paper Type: Review article.
another suggestion based on artificial neural networks.
A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res
... Show More