Systemic lupus erythematosus (SLE) is an autoimmune disease with polymorphic expression. B cells have an essential contribution in immune system activation via the production of different cytokines and functioning as potent antigen-presenting cells. Therefore, a drug that particularly targets B cells may represent an ideal therapeutic approach for SLE. Rituximab (RTX), an anti-CD20 monoclonal antibody causing transient B-cell depletion, has been used to manage SLE. This study aims to assess Rituximab effects on lupus nephritis (LN) patients when added to conventional immunosuppressants. Twenty four patients, 15-32 years old, with class III/IV/V LN were involved in this study. All were on steroids before lupus nephritis occurrence. They were given rituximab induction therapy and mycophenolate mofetil (MMF) maintenance therapy. RTX was indicated for refractory and relapsing SLE. Several investigations done before and after RTX treatment and in the last follow up (done one year after starting Rituximab). Those included protein in urine, serum creatinine, double stranded DNA, C3, C4, and Estimated Glomerular Filtration Rate (eGFR). Proteinuria decreased significantly after RTX treatment and in the last measurement (P=0.01 and P=0.001, respectively). Serum creatinine significantly decreased only in the last measurement (P=0.02). Double stranded DNA decreased remarkably after treatment (P=0.01) with a further decrease in the last measurement (P=0.006). C3 and C4 increased after treatment but the increase was significant only for C3 (P=0.002) and this increase continues till the last measurement (P=0.0006). Active urine sediments found in fifteen patients and disappeared after RTX treatment. Rituximab can be promising in treating lupus nephritis when used along with traditional immunosuppressants. It can reduce disease activity and improve renal function in such patients.
This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670
... Show MoreIn this study a new antiseptic was formulated and tested to match the effectiveness against microorganisms. The formulation consisted of Povidone - Iodine (PVP-I) (10%), H2O2 (3%) and Aloe Vera gel (pure). Different ratios of these materials were prepared within the acceptable range of pH for an antiseptic (3-6). The prepared samples were tested. The In Vitro test was performed by using four bacteria, two were Gram-Positive (Staphylococcus aureus and Bacillus cereus) and two were Gram-Negative (Escherichia coli and Pseudomonas aeruginosa). The new antiseptic showed 100% killing rate for E. coli, Ps. aeruginosa and S. aureus and 96.4667% killing rate for B. cereus. When the new antiseptic was compared with two common
... Show MoreIn this paper, variable gain nonlinear PD and PI fuzzy logic controllers are designed and the effect of the variable gain characteristic of these controllers is analyzed to show its contribution in enhancing the performance of the closed loop system over a conventional linear PID controller. Simulation results and time domain performance characteristics show how these fuzzy controllers outperform the conventional PID controller when used to control a nonlinear plant and a plant that has time delay.
Sewer system plays an indispensable task in urban cities by protecting public health and the environment. The operation, maintenance, and rehabilitation of this network have to be in a sustainable and scientific manner. For this purpose, it is important to support operators, decision makers and municipalities with performance evaluation procedure that is based on operational factors. In this paper, serviceability and performance indicator (PI) principles are employed to propose methodology comprising two enhanced PI curves that can be used to evaluate the individual sewers depending on operational factors such as flowing velocity and wastewater level in the sewers. In order to test this methodology; a case study of al-Ru
... Show MoreIn this work, synthesis of conducting polymeric films namely, PVC thin films was carried out containing Schiff base (L) with Cu2+, Cr3+, Ni2+, Co2+, in addition to inspecting the possibilities of measuring energy gap values of PVC-L-M with variety metal ions. These new polymeric films (PVC-L-M) were characterized by FTIR spectrophotometry, energy gap and surface morphology. The optical data recorded that the band gap values are influenced by the type of metals. All modified films have a red shift in optical properties in the ultraviolet region. The PVC-L-Co(II) was the lowest value of the optical band gap, 3.1 eV.
Hypocrisy is found in various aspects of life, whether in religion, politics, or social parts. Hence, some of the church's hypocrisy is an outcome of different ups and downs in life. Starting with the problem in the novel, some of the hypocritical pastors engaged in an immense role in affecting the folk's lives because they persuaded people that God ordered them to do so. To accomplish their personal interests, the abusive monks disguise their verbal speech, smiles, and fine clothes like mild sheep to delusional followers, leaving them with guilt, shame, and spiritual scars. The present study aims to examine the hypocrisy and heresy of the church as portrayed in Okezie Nwoka's novel entitled God of Mercy. It reflects the source of
... Show MoreA substantial percentage of the world’s energy consumption (almost 40%) and carbon dioxide (CO2) emissions (around 37%) come from the construction industry, especially schools. This work presents a new hybrid artificial intelligence (AI) engineering model that aims to maximize energy performance on campuses in a holistic way. Modules for data-driven forecasting, metaheuristic optimization, and real-time adaptive control are all part of the concept. A thorough energy simulation of a university campus building is used in conjunction with the AI model to assess its performance through a co-simulation framework. Findings show that yearly peak electricity demand may be reduced by 18.7% and total site energy consumption by 22.4% when co
... Show MoreSolar photovoltaic (PV) has many environmental benefits and it is considered to be a practical alternative to traditional energy generation. The electrical conversion efficiency of such systems is inherently limited due to the relatively high thermal resistance of the PV components. An approach for intensifying electrical and thermal production of air-type photovoltaic thermal (PVT) systems via applying a combination of fins and surface zigzags was proposed in this paper. This research study aims to apply three performance enhancers: case B, including internal fins; case C, back surface zigzags; and case D, combinations of fins and surface zigzags; whereas the baseline smooth duct rep