Preferred Language
Articles
/
cRZLYocBVTCNdQwC7EkW
Assessment of consistency and compressive strength of glass ionomer reinforced by different amount of hydroxyapatite
...Show More Authors

Background: Glass ionomers have good biocompatibility and the ability to adhere to both enamel and dentin. However, they have certain demerits, mainly low tensile and compressive strengths. Therefore, this study was done to assess consistency and compressive strength of glass ionomer reinforced by different amount of hydroxyapatite. Materials and Methods: In this study hydroxyapatite materials were added to glass ionomer cement at different ratios, 10%, 15%, 20%, 25% and 30% (by weight). The standard consistency test described in America dental association (ADA) specification No. 8 was used, so that all new base materials could be conveniently mixed and the results would be of comparable value and the compressive strength test described by British standard specification for zinc polycarboxylate cement was used in this study. Results: Different consistencies of materials produced a disc of varying sizes. The amount of the powder (in milligram) was mixed with 0.5 ml of liquid to produce a consistency giving a disc of 3 cm±1mm in diameter were 500 mg for glass monomer cement, 450 mg for glass ionomer cement reinforced by 10%, 5% and 30% of hydroxyapatite and 350 mg for glass ionomer cement reinforced by 20% and 25% of hydroxapatite. The results showed that the glass ionomer cement reinforced by hydroxyapatite has higher compressive strength than conventional glass ionomer. Conclusion: The addition of hydroxyapatite to conventional glass ionomer requires less powder to liquid ratio. Addition of hydroxyapatite to glass ionomer cement increased its compressive strength.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Nov 01 2021
Journal Name
Transportation Geotechnics
Evaluation of permanent deformation and resilient modulus of pavement base with different gradations and percentages of clay plasticiser
...Show More Authors

View Publication
Scopus (6)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Different Hand and Finger Grip Patterns using Surface Electromyography and Hand Dynamometry
...Show More Authors

Recording an Electromyogram (EMG) signal is essential for diagnostic procedures like muscle health assessment and motor neurons control. The EMG signals have been used as a source of control for powered prosthetics to support people to accomplish their activities of daily living (ADLs). This work deals with studying different types of hand grips and finding their relationship with EMG activity. Five subjects carried out four functional movements (fine pinch, tripod grip and grip with the middle and thumb finger, as well as the power grip). Hand dynamometer has been used to record the EMG activity from three muscles namely; Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), and Abductor Pollicis Brevis (ABP) with different le

... Show More
View Publication
Crossref (7)
Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Different Hand and Finger Grip Patterns using Surface Electromyography and Hand Dynamometry
...Show More Authors

Recording an Electromyogram (EMG) signal is essential for diagnostic procedures like muscle health assessment and motor neurons control. The EMG signals have been used as a source of control for powered prosthetics to support people to accomplish their activities of daily living (ADLs). This work deals with studying different types of hand grips and finding their relationship with EMG activity. Five subjects carried out four functional movements (fine pinch, tripod grip and grip with the middle and thumb finger, as well as the power grip). Hand dynamometer has been used to record the EMG activity from three muscles namely; Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), and Abductor Pollicis Brevis (ABP) with different

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Measurement of indoor radon levels and assessment of radiological hazards at Al-Tuwaitha nuclear site and the surrounding area
...Show More Authors

In the present study the radon concentration was measured in indoor places by the RAD7 (radon detector) was in some locations at Al-Tuwaitha nuclear site and some surrounding areas for the duration from 13/10/2016 to 2/1/2017 and the measurement of the indoor radon concentration ranged from (4.96±4.4 to 102±25) Bq/m3. The high value of radon has been found at decommissioning directorate /emergency room, which is lower than the action value recommended by the Environmental Protection Agency (EPA) which is (148 Bq/m3) while the lowest value has been founded in central laboratories directorate \ models room. These values were used to calculate the annual effective dose and the health risks for cells bronchial which caused by the inhalatio

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Apr 30 2024
Journal Name
Iraqi Journal Of Science
Assessment of Some Physiological, Immunological and Molecular Biomarkers in Sample of Iraqi Women Undergoing Caesarean Section and Normal Delivery
...Show More Authors

     Pregnancy and delivery are physiological conditions that are marked by abrupt alterations to hormones, immunological and molecular characters. The current study aimed to evaluate oxytocin (OT), prolactin (PRL), cortisol and insulin growth factor-2 (IGF-2) levels as physiological biomarkers; programmed cell death protein-1 (PD-1), programmed cell death ligand-1 (PD-L1),interleukin-6 (IL-6) as immunological biomarkers, and single nucleotide polymorphisms (SNPs; rs53576 and rs2254298) of oxytocin receptor gene OXTR as molecular factors in samples of Iraqi women undergoing caesarean section (CS) and normal delivery (ND). Blood samples were collected from 96 pregnant women at term with ages ranging between 16-43 years. Regarding

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Periodontal Health Status and Assessment of Osteocalcin levels in Saliva of Diabetic Patients and Systemically Healthy Persons (Comparative study)
...Show More Authors

ABSTRACT Background: Diabetes and periodontitis are complicated prolonged disorders through a recognized two-way association. There is elongated-conventional mark that hyperglycaemia in diabetes is affected on immune-inflammatory response and disturb the action of osteoclast and in balance bone turnover, which might rise the person vulnerability to the progress of prolonged periodontitis. Osteocalcin is one of the greatest plentiful matrix proteins originate in bones and produced absolutely there. Small osteocalcin crumbles are noticed in regions of bone remodeling and are in fact degradation products of the bone matrix, that is released outside cells into the Gingival Crevicular Fluid (GCF) and saliva after destruction of periodontal tissu

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Journal Of Engineering
Development and Verification of the Capacity Curve for Two Dimensional Reinforced Concrete Moment-Resisting Frames System under Earthquake Loading
...Show More Authors

Pushover analysis is an efficient method for the seismic evaluation of buildings under severe earthquakes. This paper aims to develop and verify the pushover analysis methodology for reinforced concrete frames. This technique depends on a nonlinear representation of the structure by using SAP2000 software. The properties of plastic hinges will be defined by generating the moment-curvature analysis for all the frame sections (beams and columns). The verification of the technique above was compared with the previous study for two-dimensional frames (4-and 7-story frames). The former study leaned on automatic identification of positive and negative moments, where the concrete sections and steel reinforcement quantities the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 02 2010
Journal Name
Journal Of Engineering
Bearing capacity of square footing on geogrid reinforced loose sand to resist eccentric load
...Show More Authors

This research presents and discuss the results of experimental investigation carried out on geogrids model to study the behavior of geogrid in the loose sandy soil. The effect of location eccentricity, depth of first layer of reinforcement, vertical spacing, number and type of reinforcement layers have been investigated. The results indicated that the percentage of bearing improvement a bout (22 %) at number of reinforced layers N=1 and about (47.5%) at number of reinforced layers N=2 for different Eccentricity values when depth ratio and vertical spacing between layers are (0.5B and 0.75B) respectively

Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Engineering
Non-Destructive Testing of Carbon Fiber Reinforced Magnetic Reactive Powder Concrete Containing Nano Silica
...Show More Authors

This study involves the design of 24 mixtures of fiber reinforced magnetic reactive powder concrete containing nano Silica. Tap water has been used in mixing 12 of these mixtures, while the other 12 have been mixed using magnetic water. Nano Silica (NS) with ratios (1, 1.5, 2, 2.5 and 3) % were used. The results showed that the mixture containing 2.5%NS gives the highest compressive strength at age 7 days. Many different other tests were carried out, the results showed that the fiber reinforced magnetic reactive powder concrete containing 2.5% NS (FRMRPCCNS)  has the higher bulk density, dynamic modulus of elasticity, ultrasonic pulse velocity  electrical resistivity and lesser absorption than fiber reinforced

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
E3s Web Of Conferences
Behavioral Investigation of Reinforced Concrete T-Beams with Distributed Reinforcement in the Tension Flange
...Show More Authors

Current design codes and specifications allow for part of the bonded flexure tension reinforcement to be distributed over an effective flange width when the T-beams' flanges are in tension. This study presents an experimental and numerical investigation on the reinforced concrete flanged section's flexural behavior when reinforcement in the tension flange is laterally distributed. To achieve the goals of the study, numerical analysis using the finite element method was conducted on discretized flanged beam models validated via experimentally tested T-beam specimen. Parametric study was performed to investigate the effect of different parameters on the T-beams flexural behavior. The study revealed that a significant reduction in the

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref