Preferred Language
Articles
/
cBduXJIBVTCNdQwCgK17
Investigation hydraulic performance of splash fills packing in cooling tower
...Show More Authors

Heat is one of the most energy forms emitted to atmosphere by industrial processes. Water is considered to be the best material to reduce heat energy since its available in nature in abundance and has the ability to absorb heat efficiently. Cooling towers are ideal alternatives to re-cool hot water instead of throwing it especially in places that lack natural water resources or when there are environmental precautions because water with high temperature would be harmful to the ecosystem when it recycled to natural resources such as rivers and lakes. Also, cooling towers considered economically feasible when using west water. This paper interests with hydraulic characteristics of a counter flow wet cooling tower which was investigated experimentally. The tower filled with splash packing with Zig-Zag pattern. Current study used treated waste water and focused fundamentally on the influence of air and water flow rates on hydraulic features of cooling tower for different access water temperatures. The dependency between pressure drop and the air and water flux was spotted. In this study, it found that within a certain ranges the pressure drop increases by 75% due to liquid flux and 70% due to air flux while pressure drop is not affected by changing temperature at all. Two empirical correlation had been founded for dry pressure drop (with R2=99.5%), and for wet pressure drop (with R2=98.13%).

Scopus Crossref
View Publication
Publication Date
Mon Mar 15 2021
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of Staff Nurses’ performance at Primary Health Care Centers in Baghdad City
...Show More Authors

Objectives: This study aimed to evaluate the performance of staff nurses at primary health care centers in Baghdad city and to compare them with their demographic characteristics of age, gender and education.
Methodology: A descriptive design was carried out at Baghdad City’s primary health care centers from January 2nd 2019 to May 1st 2020. An instrument was developed for the purpose of the study. A non-probability, multi-stage purposive sample of (52) staff nurses was recruited from nurses working at primary health care centers in Baghdad City. The instrument is used to evaluate staff nurses’ performance which includes (62) items. These items are divided to (13) main domains related to evaluation of work quantity, work quality,

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Engineering
Design And Analysis Performance of Liquid Petroleum Gases System in Residential Building; Review
...Show More Authors

Liquefied petroleum gases (LPG) consist of hydrocarbons obtained by refining crude oil, either from propane or butane or a mixture of the two. There are often other components such as propylene, butylene or other hydrocarbons, but they are not the main component. The study aims to review previous studies dealing with designing an LPG system to deliver gas to residential campuses and buildings. LPG is extracted from natural gas NG by several processes, passing through fractionation towers and then pressuring into CNG storage tanks. Gas contains several problems, including gas leakage through the pipes and leads to fires or explosions in LPG storage and distribution tanks, so safety conditions were taken in the design and implementation. T

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
2018 International Conference On Advanced Science And Engineering (icoase)
Performance of BCH and RS Codes in MIMO System Using MPFEC Diversity Technique
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Dec 19 2023
Journal Name
Journal Of Information Systems Engineering And Management
Corporate Governance Towards Sustainability Performance Quality: A Case of Listed Firms in Malaysia
...Show More Authors

The sustainable development according to the United Nation, listed firms throughout globally now routinely provide sustainability data. However, there is not enough information on Sustainability Performance Quality (SPQ) in the majority of emerging economies, including Malaysia. This study looks at how the SPQ of the top 100 Malaysian-listed businesses is affected by factors as connected with corporate governance (e.g., board meeting, board size, and board ethnic diversity). Utilizing 500 firm-year data, a longitudinal sample of 500 nonfinancial firms on the Bursa Malaysia for 2015-2019 is employed in this study. The findings from the analysis using the panel regression demonstrated that: ethnic diversity and board siz

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Tue Dec 31 2019
Journal Name
Journal Of Economics And Administrative Sciences
The Impact of Emotional Intelligence on Employee Performance in Saudi Arabia Banking Sector
...Show More Authors

Saudi Arabia’s banking sector plays an important role in the country’s development as it is among the leading sectors in the financial sector. Considering, two main Saudi banks (The National Commercial Bank and Saudi American bank), the present study aims to observe the impact of emotional intelligence on employee performance. The components of emotional intelligence affecting employee performance include self-management, relationship management, self-awareness, and social awareness. A quantitative methodology was applied to analyse the survey results of 300 respondents over the period from 2018 to 2019. The results show that there was a significant positive impact of self-management, self-awareness, and relationship manageme

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Engineering
The Effect of Staggered porous fins on the performance of Photovoltaic panel in Baghdad
...Show More Authors

The performance of photovoltaic (PV) panel having staggered metal foam fins was examined experimentally in Baghdad, Iraq. Three staggered metal foam fin configurations attached to the backside of the PV panel were studied. The measured parameters were front and back surfaces temperature, open voltage and current circuits, maximum power, and PV efficiency. It was noted that the maximum electrical efficiency enhancement was 4.7% for staggered metal foam fins (case III) than the reference PV panel. The operating temperature of the cell was increased when the value of solar intensity was high. Thereby, the electrical efficiency was decreased. It was found that the metal foam fins decreased the PV temperature by 2-3 o

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Thu Dec 28 2023
Journal Name
Al–bahith Al–a'alami
Effect of Political Factors on the Performance of Specialized Journalists in Iraqi Electronic Journalism
...Show More Authors

This study aimed to identify the political factors influencing the performance of specialized journalists in Iraqi electronic newspapers. The significance of the study stems from the role of communication in newspapers that have established themselves in reality due to their wide dissemination, multiple uses, expanding freedom base, and the current diversity in perspectives. These newspapers highlight and publish societal issues of concern. The importance of these newspapers is associated with their creators who face various factors affecting their value and performance, whether positively or negatively. In light of this, the political factor was identified as the primary driver for other influencing factors. The

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
STATIC PERFORMANCE CHARACTERISTICS OF VORTEX RATE SENSOR
...Show More Authors

The vortex rate sensor is a fluidic gyroscope with no moving parts and can be used in very difficult
conditions like radiation, high temperature and noise with minimum cost of manufacturing and
maintenance. A vortex rate sensor made of wood has been designed and manufactured to study
theoretically and experimentally its static performance .A rig has been built to carry out the study,
the test carried out with three different air flow rates (100, 150, and 200 l/min).The results show that
the relation between the differential pressure taken from the sensor pickoff points and the angular
velocity of the sensor was linear.The present work involved theoretical and experimental study of
vortex rate sensor static characteri

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Static Performance Characteristics Of Vortex Rate Sensor
...Show More Authors

The vortex rate sensor is a fluidic gyroscope with no moving parts and can be used in very difficult conditions like radiation, high temperature and noise with minimum cost of manufacturing and maintenance. A vortex rate sensor made of wood has been designed and manufactured to study theoretically and experimentally its static performance .A rig has been built to carry out the study,
the test carried out with three different air flow rates (100, 150, and 200 l/min).The results show that the relation between the differential pressure taken from the sensor pickoff points and the angular velocity of the sensor was linear.The present work involved theoretical and experimental study of vortex rate sensor static characteristics .Vortex rat

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Nov 03 2021
Journal Name
Journal Of Engineering Research
Performance of quadrilateral perforated prestressed concrete rafters
...Show More Authors

This study focuses on the behavior of simply supported perforated prestressed concrete rafters (PPCRs) under single midspan monotonic static loading. The experimental program consisted of testing seven specimens; one solid (control) rafter, and six perforated with quadrilateral openings. The main investigated variables are the number and height of the openings. The test findings indicate that, in comparison to the solid rafter, the presence of quadrilateral openings in the PPCRs led to reducing the load capacity by (4.3-36%) and increase the midspan deflection at ultimate by (14.8-33%). Also, increasing the number of concrete posts between openings resulted in increasing the failure load and decreasing the deflection at all stages o

... Show More
View Publication
Crossref (1)
Crossref