Preferred Language
Articles
/
cBcEWJIBVTCNdQwC9azc
A Past, Present, and Prospective Review on Microwave Nondestructive Evaluation of Composite Coatings
...Show More Authors

Recent years have witnessed an increase in the use of composite coatings for numerous applications, including aerospace, aircraft, and maritime vessels. These materials owe this popularity surge to the superior strength, weight, stiffness, and electrical insulation they exhibit over conventional substances, such as metals. The growing demand for such materials is accompanied by the inevitable need for fast, accurate, and affordable nondestructive testing techniques to reveal any possible defects within the coatings or any defects under coating. However, typical nondestructive testing (NDT) techniques such as ultrasonic testing (UT), infrared thermography (IRT), eddy current testing (ECT), and laser shearography (LS) have failed to provide successful results when inspecting composite coatings. Consequently, microwave NDT techniques have emerged to compensate for the shortcomings of traditional NDT approaches. Numerous microwave NDT methods have been reported for composite coatings inspection. Although existing microwave NDT methods have shown successful inspection of composite coatings, they often face several challenges, such as low spatial image quality and extensive data interpretation. Nevertheless, many of these limitations can be addressed by utilizing microwave NDT techniques with modern technologies such as soft computing. Artificially intelligent techniques have greatly enhanced the reliability and accuracy of microwave NDT techniques. This paper reviews various traditional NDT techniques and their limitations in inspecting composite coatings. In addition, the article includes a detailed review of several microwave NDT techniques and their benefits in evaluating composite coatings. The paper also highlights the advantages of using the recently reported microwave NDT approaches employing artificial intelligence approaches. This review demonstrates that microwave NDT techniques in conjunction with artificial intelligence approaches have excellent prospects for further enhancing composite coatings inspection and assessment efficiency. The review aimed to provide the reader with a comprehensive overview of most NDT techniques used for composite materials alongside their most salient features.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 02 2022
Journal Name
Journal Of The College Of Languages (jcl)
A Pragmatic Analysis of Illocutionary Act in a Selected Presidential Speech on COVID-19
...Show More Authors

     This paper aims at studying the illocutionary speech acts: direct and indirect to show the most dominant ones in a presidential speech delivered by the USA president. The speech is about the most critical health issue in the world, COVID-19 outbreak.  A descriptive qualitative study was conducted by observing the first speech delivered by president Trump concerning coronavirus outbreak and surveying the illocutionary acts: directive, declarative, commissive, expressive, and representative. Searle's (1985) classification of illocutionary speech acts is adopted in the analysis.

     What are the main types of the illocutionary speech acts performed by Trump in his speech?; Why does

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
A reflection of the integration of accounting income and economic value added on the decisions of investors
...Show More Authors

           The support qualitative information regards as an additional step in the process of decision-making where the method following by companies to provide information help in the creation of value because it is very important to deliver information to investors about their stratigies and what happen truly inside the companies i.e.  every case relating with the expectations of stockhotslder and the prices of markets depending on those expectation ,and if the matter isn’t that there will be lack of confidence thate couldn’t be backed again. The decisions of the investors effected by security ,economic ,political, psychological, emotional ,and financial factors .

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
International Scientific Congress Of Pure, Applied And Technological Sciences (minar Congress)
Evaluation Of Electromagnetic Pollution Of Cellular Mobile Network
...Show More Authors

Wireless communications are characterized by their fastest growth in history, as they used ever-evolving and renewed technologies, which have allowed them to spread widely. Every day, communication technology introduces a new invention with features that differ from its predecessor. Bell Laboratories first suggested mobile wireless communication services to the general population in the late 1940s. Still, it wasn't easy at that time to use on a large scale due to its high costs. This paper aims to describe the state of cellular mobile networks; by comparing the sources of electromagnetic pollution caused by these networks, measure the level of power density in some residential areas, and compare them with international standards adopted in

... Show More
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Enhancing Nitrate Ion Removal from Water using Fixed Bed Columns with Composite Chitosan-based Beads
...Show More Authors

    Water contamination is a pressing global concern, especially regarding the presence of nitrate ions. This research focuses on addressing this issue by developing an effective adsorbent for removing nitrate ions from aqueous solutions. two adsorbents Chitosan-Zeolite-Zirconium (Cs-Ze-Zr composite beads and Chitosan-Bentonite-Zirconium Cs-Bn-Zr composite beads were prepared. The study involved continuous experimentation using a fixed bed column with varying bed heights (1.5 and 3 cm) and inlet flow rates (1 and 3 ml/min). The results showed that the breakthrough time increased with higher bed heights for both Cs-Ze-Zr and Cs-Bn-Zr composite beads. Conversely, an increase in flow rate led to a decrease in breakthrough time. Notab

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Baghdad Science Journal
Influence of Varying Temperature and Concentration on Magnetohydrodynamics Peristaltic Transport for Jeffrey Fluid with a Nanoparticles Phenomenon through a Rectangular Porous Duct
...Show More Authors

A mathematical model constructed to study the combined effects of the concentration and the thermodiffusion on the nanoparticles of a Jeffrey fluid with a magnetic field effect the process of containing waves in a three-dimensional rectangular porous medium canal. Using the HPM to solve the nonlinear and coupled partial differential equations. Numerical results were obtained for temperature distribution, nanoparticles concentration, velocity, pressure rise, pressure gradient, friction force and stream function. Through the graphs, it was found that the velocity of fluid rises with the increase of a mean rate of volume flow and a magnetic parameter, while the velocity goes down with the increasing a Darcy number and lateral walls. Also, t

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Thu Jun 08 2023
Journal Name
Iraqi Journal Of Laser
PDF Lab-On-a-Chip an integrated microfluidic device sensitive low-Cost, and Rapid with a syringe pump for Analysis of Ibuprofen
...Show More Authors

Abstract: Microfluidic devices present unique advantages for the development of efficient drug assay and screening. The microfluidic platforms might offer a more rapid and cost-effective alternative. Fluids are confined in devices that have a significant dimension on the micrometer scale. Due to this extreme confinement, the volumes used for drug assays are tiny (milliliters to femtoliters).

 In this research, a microfluidic chip consists of micro-channels carved on substrate materials built by using Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters have influence on the width, depth, roughness of the chip. In order to have regular

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 24 2026
Journal Name
Journal Of Baghdad College Of Dentistry
In-Vitro evaluation of load-deflection characteristics and force levels of nickel titanium orthodontic archwires
...Show More Authors

Background: Nickel-titanium (NiTi) archwires have become increasingly popular because of their ability to release constant light forces, which are especially useful during initial alignment and leveling phase. The aim of the present study was to investigate and compare the load–deflection characteristics of four commercially available NiTi archwires. Materials and methods: 200 NiTi 0.014, 0.016, 0.018, 0.016x0.022 and 0.019x0.025-inch nickel–titanium archwires from four different manufacturers (3M, Ortho Technology, Jiscop and Astar) were tested. The load-deflection properties of these archwires were evaluated by a full arch bending test in both palatal and gingival directionsat 37°C temperature using a universal material t

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 17 2024
Journal Name
Veterinary World
Characterization of food color additives and evaluation of their acute toxicity in Wistar albino rats
...Show More Authors

Background and Aim: The use of food dyes can cause certain diseases, such as anemia and indigestion, along with other disorders, tumors, and even cancer. Therefore, this study aimed to determine the chemical nature and toxicity of some commercial dyes locally used in processed foods compared with standard food dyes. Materials and Methods: Three types of standard and commercial food color additives (Sunset Yellow, Tartrazine, and Carmoisine) were extensively examined. The chemical structures and functional groups of the dyes were evaluated by Fourier-transform infrared (FTIR) spectroscopy. The melting temperatures of the dyes were also determined by chemical thermal analysis. The acute toxicity test to evaluate the standard and commercial

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Tue Feb 24 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of corrosion behavior of bioceramics coated commercially pure titanium and Ti-6Al-4V alloy
...Show More Authors

Background: This study report the corrosion behavior of commercially pure titanium and Ti-6Al-4V alloy samples without coating and with hydroxyapatite, partial stabilized zirconia and mixture of partial stabilized zirconia and hydroxyapatite coating and comparison between them through electrochemical polarization tests in 37 0 C Hank's solution. Materials and methods: Electrophoretic deposition technique (EPD) was used to achieve the coating from each one of three types of the coating materials (HAP, PSZ and mixture of 50% HAP and 50%PSZ) on Cp Ti and Ti-6Al-4V alloy samples. The electrochemical corrosion test was performed when samples were exposed to Hank's solution prepared in the laboratory and the polarization potential, corrosion rate

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Evaluation of protein level’s changes in saliva and sera of Oral Squamous Cell Carcinoma patients
...Show More Authors

This study aimed to identify the changes in total protein in saliva and sera samples of patients with oral squamous cell carcinoma in comparison to those of healthy controls. These changes were followed using electrophoresis (PAGE). Meanwhile, determinations of albumin, globulin and albumin to globulin ratio were carried out on sera samples only.Two groups were the participants in the present study, 18 patients with Oral Squamous Cell Carcinoma (OSCC), and 20 ages and gender matched healthy controls.

View Publication Preview PDF
Crossref (1)
Crossref