Removal of chromium ions from a real wastewater of leather industry using electrocoagulation and reverse osmosis processes
...Show More Authors

This study focused on treatment of real wastewater rejected from leather industry in Al-Nahrawan city in Iraq by Electrocoagulation (EC) process followed by Reverse Osmosis (RO) process. The successive treatment was applied due to high concentration of Cr3+ ions (about 1600 ppm) rejected in wastewater of this industry and for applying EC with moderate power consumption and better results of produced water. In Electrocoagulation process (EC), the effect of NaCl concentration (1.5, 3 g/l), current density (C.D.) (15-25 mA/cm2), electrolysis time (1-2 h), and distance between electrodes (E.D.) (1-2 cm) were examined in a batch cell by implementing Taguchi experimental design. According to the results obtained from multiple regression and signal to noise ratio (S/N), the optimum conditions for the best removal of Cr3+ ions were, 1.5 g/l of NaCl, 25 mA/cm2 of C.D., 2 h of electrolysis time, and 1.5 cm of distance between electrodes. Also, the analysis of variance (ANOVA) indicates that the percentage of contribution followed the order: C.D. (47.26 %), time (15.56 %), NaCl conc. (13.81 %), and E.D. (5.67%). The results of multiple regression model gave R2= 88.41 % which can be considered as an acceptable agreement between predicted and experimental values. Results of confirmation test revealed that the removal efficiency of Cr3+ ions at optimum conditions was 88.80 %. The final collected solution from EC process was treated with RO process in which the effect of applied pressure and feed flowrate were investigated. Experimental results revealed that the highest values of Cr3+ Re% in permeate was 99.89 %.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Using Alternative Cogeneration Plants in Iraqi Petroleum Industry
...Show More Authors

The present paper describes and analyses three proposed cogeneration plants include back pressure steam-turbine system, gas turbine system, diesel-engine system, and the present Dura refinery plant. Selected actual operating data are employed for analysis. The same amount of electrical and thermal product outputs is considered for all systems to facilitate comparisons. The theoretical analysis was done according to 1st and 2nd law of thermodynamic. The results demonstrate that exergy analysis is a useful tool in performance analysis of cogeneration systems and permits meaningful comparisons of different cogeneration systems based on their merits, also the result showed that the back pressure steam-turbine is more efficient than other pro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun May 02 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Rationalization of costs by using the tool of the quality function deployment: / applied research in the State Company for Textile and Leather Industries
...Show More Authors

The research aims to apply one of the techniques of management accounting, which is the technique of the quality function deployment on the men's leather shoe product Model (79043) in the General Company for Textile and Leather Industries by determining the basic requirements of the customer and then designing the characteristics and specifications of the product according to the preferences of the customer in order to respond to the customer's voice in agreement With the characteristics and technical characteristics of the product, taking into account the products of the competing companies to achieve the maximum customer satisfaction, the highest quality and the lowest costs. Hence, the importance of research has emerged, which indicat

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Engineering
ORGANOCLAY FOR ADSORPTION OF BINARY SYSTEM OF POLLUTANTS FROM WASTEWATER
...Show More Authors

single and binary competitive sorption of phenol and p-nitrophenol onto clay modified with
quaternary ammonium (Hexadecyltrimethyl ammonium ) was investigated to obtain the
adsorption isotherms constants for each solutes. The modified clay was prepared from
blending of local bentonite with quaternary ammonium . The organoclay was characterized
by cation exchange capacity. and surface area. The results show that paranitrophenol is
being adsorbed faster than phenol . The experimental data for each solute was fitted well with
the Freundlich isotherm model for single solute and with the combination of Freundlich-
Langmuier model for binary system .

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Environmental Engineering And Science
Soybean peroxidase-catalysed removal of benzidines from water
...Show More Authors

Crude soybean peroxidase (SBP), isolated from soybean seed coats (hulls) at unusually low concentrations, catalyses the oxidative polymerisation of hazardous aqueous benzidine and its 3,3′-dichloro, 3,3′-dimethyl and 3,3′-dimethoxy derivatives in the presence of hydrogen peroxide. The optimum operating conditions for oxidation of 0·10 mM benzidine were investigated. At pH 5, the hydrogen peroxide-to-substrate concentration ratio was 1·5 and the minimum SBP concentration required to achieve at least 95% conversion of the benzidine in synthetic wastewater was 0·43 mU/ml. Progress curves were established for the conversion of the four substrates, and apparent first-order rate constants were derived. Enzyme-catalysed polym

... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Crossref
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Emulsified Kerosene from Water by Flotation
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Mar 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Oily Wastewater Treatment Using Expanded Beds of Activated Carbon and Zeolite
...Show More Authors

Two types of adsorbents were used to treat oily wastewater, activated carbon and zeolite. The removal efficiencies of these materials were compared to each other. The results showed that activated carbon performed some better properties in removal of oil. The experimental methods which were employed in this investigation included batch and column studies. The former was used to evaluate the rate and equilibrium of carbon and zeolie adsorption, while the latter was used to determine treatment efficiencies and performance characteristics. Expanded bed adsorber was constructed in the column studies. In this study, the adsorption behavior of vegetable oil (corn oil) onto activated carbon and zeolite was examined as a function of the concentr

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 07 2014
Journal Name
Baghdad Science Journal
Adsorption of some Metal Ions from Aqueous Solution on Iraqi Rice Bran and Its Relation to the Physical Properties of these Metal Ions
...Show More Authors

Adsorption studies were carried out to test the ability of the Iraqi rice bran (Amber type) to adsorb some metals divalent cations (Cd2+, Co2+, Cu2+, Fe2+, Ni2+, Pb2+, and Zn2+) as an alternative tool to remove these pollutants from water. The Concentrations of these ions in water were measured using flame and flamless atomic absorption spectrophotometry techniques. The applicability of the adsorption isotherm on Langmuir or Freundlisch equation were tested and found to be dependent on the type of ions. The results showed different adsorptive behavior and different capacities of the adsorption of the ions on the surface of the bran. The correlation between the amounts adsorbed and different cation parameters including (electronegativity, io

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jul 18 2022
Journal Name
World Bulletin Of Public Health (wbph)
WASTEWATER TREATMENTS: A REVIEW
...Show More Authors

Many water supplies are now contaminated by anthropogenic sources such as domestic and agricultural waste, as well as manufacturing activities, the public's concern about the environmental effects of wastewater contamination has grown. Several traditional wastewater treatment methods, such as chemical coagulation, adsorption, and activated sludge, have been used to eliminate pollution; however, there are several drawbacks, most notably high operating costs, because of its low operating and repair costs, the usage of aerobic waste water treatment as a reductive medium is gaining popularity. Furthermore, it is simple to produce and has a high efficacy and potential to degrade pollu

... Show More
Publication Date
Tue Feb 22 2022
Journal Name
Watre
Subsurface Flow Phytoremediation Using Barley Plants for Water Recovery from Kerosene-Contaminated Water: Effect of Kerosene Concentration and Removal Kinetics
...Show More Authors

A phytoremediation experiment was carried out with kerosene as a model for total petroleum hydrocarbons. A constructed wetland of barley was exposed to kerosene pollutants at varying concentrations (1, 2, and 3% v/v) in a subsurface flow (SSF) system. After a period of 42 days of exposure, it was found that the average ability to eliminate kerosene ranged from 56.5% to 61.2%, with the highest removal obtained at a kerosene concentration of 1% v/v. The analysis of kerosene at varying initial concentrations allowed the kinetics of kerosene to be fitted with the Grau model, which was closer than that with the zero order, first order, or second order kinetic models. The experimental study showed that the barley plant designed in a subsu

... Show More
Crossref (10)
Crossref
Publication Date
Tue Feb 22 2022
Journal Name
Water
Subsurface Flow Phytoremediation Using Barley Plants for Water Recovery from Kerosene-Contaminated Water: Effect of Kerosene Concentration and Removal Kinetics
...Show More Authors

A phytoremediation experiment was carried out with kerosene as a model for total petroleum hydrocarbons. A constructed wetland of barley was exposed to kerosene pollutants at varying concentrations (1, 2, and 3% v/v) in a subsurface flow (SSF) system. After a period of 42 days of exposure, it was found that the average ability to eliminate kerosene ranged from 56.5% to 61.2%, with the highest removal obtained at a kerosene concentration of 1% v/v. The analysis of kerosene at varying initial concentrations allowed the kinetics of kerosene to be fitted with the Grau model, which was closer than that with the zero order, first order, or second order kinetic models. The experimental study showed that the barley plant designed in a subsu

... Show More
Scopus (12)
Crossref (10)