This study focused on treatment of real wastewater rejected from leather industry in Al-Nahrawan city in Iraq by Electrocoagulation (EC) process followed by Reverse Osmosis (RO) process. The successive treatment was applied due to high concentration of Cr3+ ions (about 1600 ppm) rejected in wastewater of this industry and for applying EC with moderate power consumption and better results of produced water. In Electrocoagulation process (EC), the effect of NaCl concentration (1.5, 3 g/l), current density (C.D.) (15-25 mA/cm2), electrolysis time (1-2 h), and distance between electrodes (E.D.) (1-2 cm) were examined in a batch cell by implementing Taguchi experimental design. According to the results obtained from multiple regression and signal to noise ratio (S/N), the optimum conditions for the best removal of Cr3+ ions were, 1.5 g/l of NaCl, 25 mA/cm2 of C.D., 2 h of electrolysis time, and 1.5 cm of distance between electrodes. Also, the analysis of variance (ANOVA) indicates that the percentage of contribution followed the order: C.D. (47.26 %), time (15.56 %), NaCl conc. (13.81 %), and E.D. (5.67%). The results of multiple regression model gave R2= 88.41 % which can be considered as an acceptable agreement between predicted and experimental values. Results of confirmation test revealed that the removal efficiency of Cr3+ ions at optimum conditions was 88.80 %. The final collected solution from EC process was treated with RO process in which the effect of applied pressure and feed flowrate were investigated. Experimental results revealed that the highest values of Cr3+ Re% in permeate was 99.89 %.
An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreThe present study explores the solar-induced photocatalytic degradation of reactive red (RR) and reactive turquoise (RT) dyes in a single system using TiO2 immobilized in xanthan gum (TiO2/XG), synthesized using the sol–gel dip-coating technique for direct precipitation. SEM-EDX, XRD, FTIR, and UV–Vis were used to assess the characteristics of the resulting catalyst. Moreover, the effects of different operating parameters, specifically pH, dye concentration, TiO2/XG concentration, H2O2 concentration, and contact time, were also investigated in a batch photocatalytic reactor. The immobilized TiO2/XG catalyst showed a slight adsorption degradation efficiency and then improved the RR and RT dye degradation activity (92.5 and 90.8%
... Show MoreDensity Functional Theory at the generalized-gradient approximation level coupled with large unit cell method is used to simulate the electronic structure of (II-VI) zinc-blende cadmium sulfide nanocrystals that have dimensions 2-2.5 nm. The calculated properties include lattice constant, conduction and valence bands width, energy of the highest occupied orbital, energy of the lowest unoccupied orbital, energy gap, density of states etc. Results show that lattice constant and energy gap converge to definite values. However, highest occupied orbital, lowest unoccupied orbital fluctuates indefinitely depending on the shape of the nanocrystal.
In this study, novel Schiff base complexes with Zn(II) and Co(II) ions were successfully synthesized. The malonic acid dihydrazide was converted into the Schiff base ligand by combining it with 1-hydroxy-2-naphthaldehyde, and the last step required reacting it with the appropriate metal(II) chloride to produce pure target complexes. The generated complexes were thoroughly characterized using FTIR, 1H-NMR, 13C-NMR, GC-mass, and UV-Vis spectroscopies. In order to photo-stabilize polystyrene (PS) and reduce the photodegradation of its polymeric chains, these chemicals have been used in this work. The efficiency of the generated complexes as photo-stabilizers was evaluated using a variety of techniques, including FTIR, weight loss, visc
... Show MoreHouse 21 fungal isolates fungus to the analyst Albroca output of manufactured blood clot from the Blama human blood showed positive fungi to test analyzes blood clot variation in times where decomposition recorded fungi
Background: The skin functions as a barrier to the external environment, damage to this barrier following a burn disrupts the innate immune system and increases susceptibility to bacterial infection. Objective: This study was carried out to determine the bacterial isolates and study their antimicrobial susceptibility in burned wound infections at one burn's hospital in Baghdad.Type of study:Cross-sectional study.Methods: The bacteria were identified at species level by using Analytic Profile Index (API) system and The antimicrobial susceptibility test was performed according to Kirby-Bauer (disk diffusion) technique.Results: Over a period of one year (from October 2014 to October 2015). Out of 848 patients with different degrees of burns
... Show MoreThirty one samples of gum swabs were collected from patients with tooth caries (5-30 years old) from the College of Science (Biology department )- University of Baghdad- Iraq for the period from October 2018 to December 2018. , The samples were transported, after inoculation in a transport media (nutrient broth), to the laboratory of the College of Science and then cultured on mannitol salt agar and blood agar). The isolates belonging to Staphylococcus spp. were identified by biochemical tests and Vitek 2 compact system, while the more antibiotic resistant isolates were identified by using Polymerase Chain Reaction(ï´¾PCR) and sequencing of 16SrRNA . The results showed sharp UV absorption peaks at 330 - 340nm and AFM at 5
... Show More