the study covered theoretical concering parial molal volume the applicability of jones-dole equation
This study included the compromised the containing Hardness and some ions of treated water in central Karbala drinking water treatment station with Iraqi and international drinking water criteria. Also, this study was attempted to focus on probable pollution sources. The Hardness and other waters salts Sulphates (SO4), Chloride ion (Cl-), Calcium ion (Ca+2), and Magnesium ion (Mg+2) tests criteria were determined on water samples taken from Al-Hussainia River water source, treated drinking water during October-November 2013 to August - September 2014.Study results revealed an increasing in Total hardness (TH), sulfate, chloride, calcium, in winter (December- January) 2014. In addition, the results showed a decrease in above mentioned cri
... Show MoreThis in vivo study was conducted to investigate the effect of different concentrations of ozonated water on experimentally skin infection with some of bacterial isolates (Pseudomonas aeruginosa and Staphylococcus aureus ) which Showed dermal infection in experimental animals after 48 hours of exposure to these Microorganisms. Results revealed that ozone has the power to accelerated the healing process depending on the perfect concentration of ozonated water used and the severity of infection & nature of causative agent , in which the recovering period was 7 days for the infection caused by P. aeruginosa and 5 day for S.aureus by using the concentration 60 µg/ml . Results also indicated in this study the stimulated effect of O
... Show MoreWater injection equipments such as pipelines, which are used in the second recovery of oil in the Al-Ahdeb wells, suffer from the corrosion in water during maintaining vacuum deoxygenated tower that used to decrease concentration of the dissolved oxygen gas in the water from 6.2-9.1 ppm to o.5 ppm. This study involved calculation the corrosion rates of the internal surfaces of the pipelines either during operation of the vacuum unit or when the tower out of operation. Finally, find the solution by one of the following suggestions. In the first suggestion removal of the dissolved O2 from water is achieved by increasing the dosage of the oxygen scavenger (sodium sulphite). The second suggestion involves re
... Show MoreThis paper study the ability of Enterobacter cloacae for degrading crude oil in contaminated water. Six isolates of E. cloacae were isolated from hydrocarbon contaminated soil and water of different sites. The isolate E. cloacae E1 showed the highest emulsification index (E24%) reached 62% thus it was chosen for further study. Biosurfactant produced by E. cloacae E1 reduced the surface tension of the medium from 64 to 36 mN/m. pH range 6.5 – 7 and temperature range 30˚C - 35˚C were the optimal conditions for maximum degradation. After 30 days of incubation, E. cloacae E1 degraded 70.00 ± 0.40% of the crude oil. GC-MS analysis revealed that E. cloacae E1 was able to degrade aromatic compounds. This study proved that E. cloacae E1 con
... Show MoreCurrent study aimed to investigate the effect of cigarette and water pipe smoking on smoker immunity comparing to non smoker. Twenty blood samples were collected from smoker students and twenty blood samples from non smoker students from Baghdad university in 2014.The results showed that there was increase in W.B.Cs total count in smoker group comparing to non smoker in a significant differences P<0.05. The differential W.B.Cs count results shows that there are increase was neutrophiles and Monocytes while there is decrease in lymphocytes in smoker group comparing to non smokers in a significant differences P<0.05 .Also the results revealed that there is an increase in percentage of phagocytosis to Staphyllociccus aureus bacteria b
... Show MoreMolecular interactions between 2-isopropenylnaphthalene-methacrylic acid (IPNMA) block copolymer( as a model for water- soluble polymer) and methanol at several temperatures were studied using fluorescence techniques , Fluorescence spectrum for (IPNMA) exhibits two emission bands at around 342 nm and 387 nm corresponding to the monomer and the excimer bands , respectively .The fluorescence spectra of dilute solution of (IPNMA) in methanol were recorded in temperature range of 8- 45?C . Plot of the excimer to monomer intensity ratio Ie/Im versus temperature was obtained, which shows double lines with positive slopes crossing at 25?C , the increasing of slope value above this temperature is s
... Show MoreMonitoring water quality in hemodialysis systems is extremely important to maintain adequate quality services for patients suffering from kidney failure. This work aims to examine and evaluate bacteriological characteristics and endotoxin contamination levels in hemodialysis water produced in dialysis centers. Forty‐eight water samples were collected and analyzed from four major hospitals in Baghdad for one year to evaluate seasonal effects. The analysis included the determination of total heterotrophic bacteria using the pour plate method, identification of bacterial isolate using the Vitek2 compact instrument, and the determination of endotoxins levels using Limulus ameboc
A study of irrigation water was conducted Baghdad city to find out extent of its pollution by some heavy metals (Pb, Cd, Ni, Co, CU, Cr, Zn and Fe). Water samples were collected randomly from different sources (river, well and stream). Results showed that the concentration of studied heavy metals were as follows: Lead between 0.43-11.75 mg L-1, Cadmium between 0.01-0.95 mg L-1, Nickel between 0.008-0.46 mg L-1, Cobalt between Nil - 0.185 mg L-1, Copper is between 0.326 - 1.58 mg L-1, Chromium is between Nil-0.068 mg L-1, Zinc 0.398-1.182 mg L-1, as for Iro
Atotal of 551 water samples drinking( five Water Treatment Plans (WTPs) and raw water( from different sites on Tigris river) were collected.According to morphological characteristics and a set of biochemical tests, one hundred twenty eight of Aeromonas spp isolates were obtained In this study The percentages of Aeromonas recovery from river water was 72.52%, from wells water was (35%).Total percentage of positive aeromonas samples of treated water(Filtration &chlorine tank, supply water of WTPs, distribution system, reserviores and other samples not related to WPTs) was 8.8%.Count of Aeromonas in positive aeromonas samples ranging from 1 to 175 cfu 100 ml.
The results showed that generally no significant correlation between presen