The existing investigation explains the consequence of irradiation of red laser on the optic properties of (CoO2) films. The film was equipped by the utilization of semi-computerized spray pyrolysis technique (SCSPT), it is the first time that this technique is used in the preparation and irradiation using a laser in this technique. From the XRD analysis, the crystalline existence with trigonal crystal system was when the received films were processed by continuous red laser (700 nm) with power (>1000mW)for different laser irradiation time using different number of times a laser scan (0, 6, 9, 12, 15 and 18 times) with total irradiation time(0,30,45,60,75,90 min) respectively at room temperature. The optic properties of CoO2 thin samples was struck by light of red laser. The parameters such as the absorbance, coefficient of absorption coefficient of extinction refractive index, optic conductivity, the realϵ_1 and imaginaryϵ_2part of the dielectric constant of the films rises subsequently by laser irradiation, only the transmittance was decremented with laser ray of light. The optic energy gap was reduced from (1.91eV) without irradiation to (1.57eV) and subsequent laser irradiation, and there is a great alteration of optical energy gap values for photovoltaic (PV) utilization. As the results showed that the laser irradiation method has a clear change in the optical properties with less time and energy than the traditional annealing methods, this is the aim of the study.
Thin-walled members are increasingly used in structural applications, especially in light structures like in constructions and aircraft structures because of their high strength-to-weight ratio. Perforations are often made on these structures for reducing weight and to facilitate the services and maintenance works like in aircraft wing ribs. This type of structures suffers from buckling phenomena due to its dimensions, and this suffering increases with the presence of holes in it. This study investigated experimentally and numerically the buckling behavior of aluminum alloy 6061-O thin-walled lipped channel beam with specific holes subjected to compression load. A nonlinear finite elements analysis was used to obtain the
... Show MoreThe concentration of elements were analyzed of twelve cultivation medium (Peat moss, Perlite and Hermon) selected from Iraqi markets using X-ray fluorescence techniques. The analytical results show that the cultivation medium contained high concentration of (Na, Al, Si, S, K, Ca, Fe) and low concentration of (Mg, P, Cl, Ti, V, Cr, Mn, Co, Ni, Cu, Zn). The samples also contained trace concentration of (Ge, As, Se, Br, Sr, Y, Mo, Cd, I, Hg, Pb, U). The results were compared using atomic absorption spectrophotometric technique for measuring the concentration of (K, Ca, Cu, Mn, Zn, Pb).
The Results showed that there is significant difference in the concentration of each element in most of the samples. The concentrations of elements a
... Show MoreThe study area is encompassed by the 33.59-34.93°N latitudes and 45.44-46.39°E longitudes and divided into four groups with respect to earthquake event locations. We determined fault plane solutions, moment magnitudes, focal depths, and trend of slip with the direction of the moment stress axes (P, N, and T) for 102 earthquakes. These earthquakes had a local magnitude in the range between 4.0 and 6.4 for the time period from January 2018 to the end of August 2019, with focal depths ranged between 6 and 17 km. Waveform moment tensor inversion technique was used to analyze the database constructed from seismic stations on local and neighboring country networks (Iraq, Iran, and Turkey). We separated the studie
... Show MoreThis research is studying technique sculptures super - realism, search through, how the method of work, and the search for the materials used in their manufacture, and this is the first study in the field of art and the field of academic study in the country.Research consists of an introduction, And four sections, The introduction containing information on: research problem, Importance of research, Goals of the research, Limits of research, research approach, and research tools.The first section contains a technical study sculptures super -realism in contemporary sculpture, while the second section includes a search for alternative materials available in the local markets, for making sculptures super - realism, the third section dedicate
... Show MoreThis contribution investigates the impact of adding transition metal of Ti to CeOy samples at various concentrations referring to 0, 15.84, 24.46, 34.46, 36.23, 38.46, 45.38% and pure TiOy, correspondingly. The samples were fabricated by the magnetron sputtering technique. X-ray diffraction (XRD) configurations demonstrate the presence of α-Ce2O3 and Ce2O3 phases with increased Ti contents in the systems. X-ray photoelectron spectroscopy (XPS) experimentation confirms the purity of the S1-sample (CeO2) and the purity of the S8-sample (TiO2). Further XPS analysis reveals that Ti incorporation in the doped systems functions as a reducing agent because of the existence of α-Ce2O3 and Ce2O3 phases. Moreover, based on UV–vis spectroscopy res
... Show MoreComputer-aided modeling and simulation software programs are essential tools
to predict how an optical communication component, link, or network will function
and perform. This paper aims to investigate the various effects on pulses
propagation in optical transmission systems utilizing the MATLAB program.
Dispersion and Attenuation effects are explored. The simulation of Gaussian pulses
propagation through single mode optical fiber, simplifies the design of optical
communication system and make the design process more efficient, less expensive,
and faster.
The major function of the kidney is the filtration and secretion of the final products of metabolism and the excess of electrolytes. The term kidney failure denotes inability of the kidneys to perform excretory function leading to retention of nitrogenous waste products from the blood. Biosensor are most accurate, with a rapid diagnosis ,more costly method than the traditional method to avoid any biological changes in blood sample that lead to changes optical characteristic (refractive index and absorption) of blood sample. The current study was designed to single mode more Sensitivity than multi mode for Biomarkers were recorded for Albumin 5447.06, 5193.93 and Urea sample 2623.14, 1998.44 in sm and mm respectively .
... Show MoreThis contribution investigates the impact of adding transition metal of Ti to CeOy samples at various concentrations referring to 0, 15.84, 24.46, 34.46, 36.23, 38.46, 45.38% and pure TiOy, correspondingly. The samples were fabricated by the magnetron sputtering technique. X-ray diffraction (XRD) configurations demonstrate the presence of α-Ce2O3 and Ce2O3 phases with increased Ti contents in the systems. X-ray photoelectron spectroscopy (XPS) experimentation confirms the purity of the S1-sample (CeO2) and the purity of the S8-sample (TiO2). Further XPS analysis reveals that Ti incorporation in the doped systems functions as a reducing agent because of the existence of α-Ce2O3 and Ce2O3 phases. Moreover, based on UV–vis spectroscopy res
... Show MoreElectrochemical method was used to prepare carbon quantum dots (CQDs). Size of matter was nature when evaluate via X-ray diffraction (XRD). A distinct peak at 2θ equal to 31.6° and three other small peaks at 38.28°, 56.41° and 66.12° were observed. The measures of Fourier Transform Infrared Spectroscopy (FTIR) showed the bonds in the transmittance spectrum are manufactured with carbon nanostructures in view. The first peaks are the O–H stretching vibration bands at (3417 and 2922) cm−1, (C–O–H at 1400, and 1317) cm−1, (C–H), (C=C), (C–O–H), (C=O), and (C–O) bonds at 2850, 1668, 1101, and 1026 cm−1 sequentially. The transmission electron microscopy (TEM) results presented that the spherical CQDs are in shape and on a
... Show MoreThe ascorbic acid content of juices of some fruits and pharmaceutical tablets of Vitamin C was determined by a homemade apparatus of DIE technique using a thermocouple as heat sensor. The method is simple, speed, low cost and the different types of turbid, colored samples can be analyzed without any problem. The results were of a valuable accuracy and precision, and the recovery of results was with acceptable values