A new method for determination of allopurinol in microgram level depending on its ability to reduce the yellow absorption spectrum of (I-3) at maximum wavelength ( ?max 350nm) . The optimum conditions such as "concentration of reactant materials , time of sitting and order of addition were studied to get a high sensitivity ( ? = 27229 l.mole-1.cm-1) sandal sensitivity : 0.0053 µg cm-2 ,with wide range of calibration curve ( 1 – 9 µg.ml-1 ) good stability (more then24 hr.) and repeatability ( RSD % : 2.1 -2.6 % ) , the Recovery % : ( 98.17 – 100.5 % ) , the Erel % ( 0.50 -1.83 % ) and the interference's of Xanthine , Cystein , Creatinine , Urea and the Glucose in 20 , 40 , 60 fold of analyate were also studied .
Industrial dyes are major pollutants in wastewater and river water with an initial visible concentration of 1 mg/L. Recent studies have shown the possibility of using polyphenol oxidase in catalytic biological treatment due to its ability to oxidize a large number of dyes and pollutants in wastewater and the flexibility to work in wide ranges of temperature, pH and salinity. It is easy availability as well as the low economic cost resulting from its use in biological treatments, this enzyme polyphenol oxidase was used. The findings in this study showed that the extraction of polyphenol oxidase (PPO) from potato peel was homogenized with potassium phosphate buffer (0.1 M, pH 7) at a ratio of 1:10 (weight: volume) for two min. The res
... Show MoreOptical fiber technology is without a doubt one of the most significant phases of the communications revolution and is crucial to our daily lives. Using the free version (2022) of RP Fiber Calculator, the modal properties for optical fibers with core radii (1.5−7.5) μm, core index (1.44−1.48) and cladding index (1.43−1.47) have been determined at a wavelength of 1000 nm. When the fiber core’s radius is larger than its operating wavelength, multimode fibers can be created. The result is a single-mode fiber in all other cases. All of the calculated properties, it has been shown, increase with increasing core radius. The modes’ intensity profiles were displayed.
Background: The patient's vital signs must stay stable pre a pulmonary function test since the approach demands the patient to breathe slowly and deeply and exhale quickly. However, events that cause variations in normal vital signs may impact the patient. Many strategies can be utilized to stabilize vital signs, including music treatment. The purpose of this study is to compare the effectiveness of music therapy on the vital signs of client's pre a pulmonary function test. Methods: An experimental design study with an application (pre-test, post-test), to determine the effectiveness of music therapy for clients pre pulmonary function test for 106 clients in Al-Diwaniyah, Al-Shamiya, and Al- Hamza public hospitals In Iraq. Parti
... Show MoreAcute appendicitis is the most common surgical abdominal emergency. Its clinical diagnosis remains a challenge to surgeons, so different imaging options were introduced to improve diagnostic accuracy. Among these imaging modality choices, diagnostic medical sonography (DMS) is a simple, easily available, and cost effective clinical tool. The purpose of this study was to assess the accuracy of DMS, in the diagnosis of acute appendicitis compared to the histopathology report, as a gold standard. Between May 2015 and May 2016, 215 patients with suspected appendicitis were examined with DMS. The DMS findings were recorded as positive and negative for acute appendicitis and compared with the histopathological results, as a gold standard
... Show MoreZinc Oxide nanoparticles were prepared using pulsed laser ablation process from a pure zinc metal placed inside a liquid environment. The latter is composed of acetyltrimethylammonium bromide (CTAB) of 10−3 molarity and distilled water. A Ti:Sapphire laser of 800 nm wavelength, 1 kHz pulse repetition rate, 130 fs pulse duration is used at three values of pulse energies of 0.05 mJ, 1.11 mJ and 1.15 mJ. The evaluation of the optical properties for the obtained suspension was applied through ultraviolet–visible absorption spectroscopy test (UV/VIS). The result showed peak wavelengths at 210 nm, 211 nm and 213 nm for the three used pulse energies 0.05 mJ, 1.11 mJ and 1.15 mJ respectively. This indicates a blue shift,
... Show MoreTen isolates of Klebsiella pneumoniae, seven isolates of Pseudomonas aeruginosa and nine isolates of Staphylococcus aureus, were obtained from 100 urine samples collected from Baghdad hospitals. All isolates were identified biochemically and confirmed by using VITEK 2 and were then tested for their susceptibility towards 6 antibiotics and for phenolic extracts of Thymus vulgaris and Cinnamomum cassia. All bacteria were greatly affected by T. vulgaris, especially K. pneumoniae. Viable count was performed, it was noted that the number of bacterial cells reduced from 1×108 CFU to 1.2× 103, 2×105 and 1.8×106CFU of K. pneumoniae, P. aeruginosa and S. aureus respectively. While C. cassiahad a slight effect on them. K. pneumoniae isola
... Show MoreАннотация
в статье рассматриваются проблемы преподавания русской литературы в иракской аудитории.. Использование литературы в преподавании иностранного языка, как правило, имеет две цели. Первая-чисто лингвистическая .. Вторая цель, однако, ассоциируется больше с экстралингвистикой и представляет собой ознакомление студентов с различными аспектами русской жизни, культуры,
... Show MoreAbstract: Polarization beam splitter (PBS) integrated waveguides are the key components in the receiver of quantum key distribution (QKD) systems. Their function is to analyze the polarization of polarized light and separate the transverse-electric (TE) and transverse-magnetic (TM) polarizations into different waveguides. In this paper, a performance study of polarization beam splitters based on horizontal slot waveguide has been investigated for a wavelength of . PBS based on horizontal slot waveguide structure shows a polarization extinction ratio for quasi-TE and quasi-TM modes larger than with insertion loss below and a bandwidth of . Also, the fabrication tolerance of the structure is analyzed.<
... Show More