Most companies use social media data for business. Sentiment analysis automatically gathers analyses and summarizes this type of data. Managing unstructured social media data is difficult. Noisy data is a challenge to sentiment analysis. Since over 50% of the sentiment analysis process is data pre-processing, processing big social media data is challenging too. If pre-processing is carried out correctly, data accuracy may improve. Also, sentiment analysis workflow is highly dependent. Because no pre-processing technique works well in all situations or with all data sources, choosing the most important ones is crucial. Prioritization is an excellent technique for choosing the most important ones. As one of many Multi-Criteria Decision Making (MCDM) methods, the Analytic Hierarchy Process (AHP) is preferred for handling complicated decision-making challenges using several criteria. The Consistency Ratio (CR) scores were used to examine pair-wise comparisons to evaluate the AHP. This study used two judgment scales to get the most consistent judgment. Firstly, the Saaty judgment scale (SS), then the Generalized Balanced Scale (GBS). It investigated whether two different AHP judgment scales would affect decision-making. The main criteria for prioritizing pre-processing techniques in sentiment analysis are Punctuation, Spelling, Number, and Context. These four criteria also contain sub-criteria. GBS pair-wise comparisons are closer to the CR value than SS, reducing the alternatives’ weight ratios. This paper explains how AHP aids logical decision-making. Prioritizing pre-processing techniques with AHP can be a paradigm for other sentiment analysis stages. In short, this paper adds another contribution to the Big Data Analytics domain.
Data steganography is a technique used to hide data, secret message, within another data, cover carrier. It is considered as a part of information security. Audio steganography is a type of data steganography, where the secret message is hidden in audio carrier. This paper proposes an efficient audio steganography method that uses LSB technique. The proposed method enhances steganography performance by exploiting all carrier samples and balancing between hiding capacity and distortion ratio. It suggests an adaptive number of hiding bits for each audio sample depending on the secret message size, the cover carrier size, and the signal to noise ratio (SNR). Comparison results show that the proposed method outperforms state of the art methods
... Show MorePolymer electrolytes systems compose of (PEO+KI+I2) and (PEO+RbI+I2) with different concentration, and a fixed amount of ethylene carbonate (EC) and propylene carbonate (PC) over temperatures range 293-343 K prepared by solution cast me
... Show MoreData steganography is a technique used to hide data, secret message, within another data, cover carrier. It is considered as a part of information security. Audio steganography is a type of data steganography, where the secret message is hidden in audio carrier. This paper proposes an efficient audio steganography method that uses LSB technique. The proposed method enhances steganography performance by exploiting all carrier samples and balancing between hiding capacity and distortion ratio. It suggests an adaptive number of hiding bits for each audio sample depending on the secret message size, the cover carrier size, and the signal to noise ratio (SNR). Comparison results show that the proposed method outperforms state of the art methods
... Show MoreBackground: Surgery is one and may be the most effective method to treat obesity. In the last decade, Laparoscopic Sleeve Gastrectomy is perceived to be less invasive, technically simple, less morbid and more popular form of bariatric surgery.
Objectives: This study aims to assess the effect of Laparoscopic Sleeve Gastrectomy on Fasting Blood Glucose Levels and Blood Pressure.
Methods: A prospective controlled study in which 50 obese patients were involved, 36 of patients have hypertension and type 2 diabetes mellitus , 7 patients have type 2 diabetes mellitus only, and 7 patients don’t have hypertension or type 2 diabetes. All patients were submitted to Laparosco
... Show MoreDue to the broad range uses of chromium for industrial purposes, besides its carcinogenic effect, an efficient, cost effective removal method should be obtained. In this study, cow bones as a cheap raw material were utilized to produce active carbon (CBAC) by physiochemical activation, which was characterized using: SEM to investigate surface morphology and BET to estimate the specific surface area. The best surface area of CBAC was 595.9 m2/gm which was prepared at 600 ᵒC activation temperature and impregnation ratio of 1:1.5. CBAC was used in aqueous chromium ions adsorption. The investigated factors and their ranges are: initial concentration (10-50 mg/L), adsorption time (30-300 min), temperature (20-50
... Show Moreto study the discribrion and the pollution in the environment in the south of baghdad samples of waste water from industrail units using the mercury in its process also
The problem of soil contamination is increased recently due to increasing the industrial wastes such as petroleum hydrocarbon, organic solvents, and heavy metals as well as maximizing the use of agricultural fertilizers. During this period, wide development of data collection methods, using remote sensing techniques in the field of soil and environment applications appear and state the suitable technique for remediation. This study deals with the application of remote sensing techniques in geoenvironmental engineering through a field spectral reflectance measurements at nine spots of naturally hydrocarbons contaminated soil in Al-Daura Refinery Company site which is located to the south west of Baghdad using radiometer device to get stan
... Show MoreThe work demonstrates the effect of cold atmospheric plasma (CAP) on adult female rats suffering from osteoporosis, the used plasma was generated by a floating electrode-dielectric barrier discharge system with an electrode diameter of 3 cm. The output power was from (12-20) watts. The effect of non-thermal plasma was observed on rats with various exposure times of 20, 30, and 40 sec. It was noted that the blood calcium percentage of animals exposed to cold plasma increased, as well as an increase in the level of vitamin D3 at the same time, it is noted that there is no effect on parathyroid hormone level. For the thyroid gland, it is noticed an increase in the level of T3, and T4 hormones in the blood during the period of induction for
... Show More