The numerical simulation for the low frequency waves in dusty plasma has been studied. The studying was done by taking two special cases depending on the direction of the propagation of the wave:First, when the propagation is parallel to the magnetic field K//B,this mode is called acoustic mode.Second,when K B this mode is called cyclotron mode.In addition, every one of the two modes divided into two modes depending on the range of the frequency.The Coulomb coupling parameter was studied, with temperature T,density of the dust particles Nd ,and the charge of the particle Qd.The low frequency electrostatic waves in dusty grains were studied. Also, the properties of ion-acoustic waves and ion-cyclotron waves are shown to modify even through the dust grains do not participate in the wave dynamics. If the dust dynamics induced in the analysis, new “ dust modes “ appear.
With the development of communication technologies, the use of wireless systems in biomedical implanted devices has become very useful. Bio-implantable devices are electronic devices which are used for treatment and monitoring brain implants, pacemakers, cochlear implants, retinal implants and so on. The inductive coupling link is used to transmit power and data between the primary and secondary sides of the biomedical implanted system, in which efficient power amplifier is very much needed to ensure the best data transmission rates and low power losses. However, the efficiency of the implanted devices depends on the circuit design, controller, load variation, changes of radio frequency coil’s mutual displacement and coupling coef
... Show MoreNon-thermal atmospheric pressure plasma has emerged as a
new promising tool in medicine and biology. In this work, A DBD
system was built as a source of atmospheric pressure non-thermal
Plasma suitable for clinical and biological applications. E. coli and
staphylococcus spp bacteria were exposed to the DBD plasma for a
period of time as inactivation (sterilization) process. A series of
experiments were achieved under different operating conditions. The
results showed that the inactivation, of the two kinds of bacteria, was
affected (increasing or decreasing) according to operation conditions
because they affects, as expected, the produced plasma properties
according to those conditions.
This paper aims to study the fractional differential systems arising in warm plasma, which exhibits traveling wave-type solutions. Time-fractional Korteweg-De Vries (KdV) and time-fractional Kawahara equations are used to analyze cold collision-free plasma, which exhibits magnet-acoustic waves and shock wave formation respectively. The decomposition method is used to solve the proposed equations. Also, the convergence and uniqueness of the obtained solution are discussed. To illuminate the effectiveness of the presented method, the solutions of these equations are obtained and compared with the exact solution. Furthermore, solutions are obtained for different values of time-fractional order and represented graphically.
A number of pulsed experiments have been carried out using a high-voltage circuit containing R,L, and C in certain arrangements. A spherical spark gap of steel electrodes was used as a high-current switch operated by a voltage of up to 8kV and triggered in both self-triggering and third-electrode triggering modes. Current measurements were carried out by using both current-viewing resistor and Rogowski coils designed for this purpose. Typical current waveforms have shown obvious dominating inductance effect of the circuit components in an underdamped oscillation. The behavior of the circuit impedance was studied by recording both pulsed current peaks and the charging voltages when currents of up to 2.5kA were recorded. The dur
... Show MoreThe motion of fast deuterons in most dense plasma focus devices ( DPF ) , may be characterized that it has a complex nature in its paths and this phenomena by describing a through gyrating motion with arbitrary changes in magnitude and direction . In this research , we focused on the understanding the theoretical concepts which depend deeply on the experimental results to explain the deuteron motions in the pinch region , and then to use the fundamental physical formulas that are deeply related to the explanation of this motion to prepare a suitable model for calculating the vertical and radial components for deuteron velocity by improving the Rung – Kutta Method
Numerical simulation of charge density produced in plasma actuators is dependent upon the development of models dealing with electrical properties. The main aim of this work is to investigate the characteristics surface charge density and space charge density of DBD plasma actuator. A simple design of surface dielectric barrier discharge plasma actuator is used in the study. The discharge gas was N2:H2 mixture with applied voltage equal to 1.5 kV. A theoretical plasma model is used to establish the charge density details. Results show that surface charge density increased in value and spread in width alone the exposed electrode as the voltage increased and reached to the amplitude value.
Objectives: To determined the levels of lipid profile (TC, TG, HDL-c, LDL-C, VLDL) in diabetic and diabetic neuropathy patients and compare the results with control group. Also, to compare Atherogenic Index of Plasma (AIP) levels in these groups that may be predict prone of patients to cardiovascular disease. Methodology: Ninety subjects were enrolled in this study with aged ranged (40-65) years and BMI with (30-35) Kg/m2 that divided into three groups as follows: group one (G1) consists of 30 healthy individuals as a control group, group two (G2) consists of 30 patients with diabetes and group three (G3) consists of 30 patients with diabetes and neuropathy as complication. Electrochemical Skin Conductance (Feet Mean), Electrochemic
... Show MoreDue to the importance of the extraction process in many engineering and medical industries, in addition to great interest in medicinal plants, in this research, microwave-assisted extraction has been applied to extract some active compounds from Rosmarinus officinalis leaves. The optimal extraction conditions were then determined by calculating the ratio and extraction efficiency. The process has also been described through kinetic study by applying five kinetic models, the Hyperbolic diffusion model, Power low model, the First order reaction model, Elovich's model, and Fick's second law diffusion model and determining their compatibility with the studies operation, and determining the kinetic constants for each model. The result
... Show MoreThe current study was designed to investigate the occurrence of aflatoxin B1 in thirty two samples of fish feedstuff were collected randomly from some Iraqi local markets using ELISA technique. Aflatoxin B1 was detected in thirty samples and the concentration of toxin ranged from 50 ppb to 1000 ppb.
Microwave and ozone were used for detoxification of aflatoxin B1 from sample with highest concentration (1000 ppb), two degree of temperature and two times (50°C and 100°C for 5 minute and 10 minute to each degree) of microwave, also two doses and two times (2 g and 4 g for 5 minute and 10 minute to each dose) of ozone gas were used.
Degradation of aflatoxin B1 by
... Show More