This study was conducted in the Poultry farm of the animal during the Production department, Iraqi during the (Ministry of Science and Technology) period from 3-9-2001 to 8-4-2002. The objectives of this study were to evaluate the effect of low – level chronic aflatoxicosis on performance (body weight, feed conversion efficiency and mortality), Serum biochemistry and activity of some enzymes (GOT,GPT, ALKP, LDH). A total of 300 male chicks of broiler breeder (Faw–Bro) were used. Chicks at day 1 of age were fed diets contaminated with aflatoxine at levels of 0, 0.3, 0.6, 0.9, 1.2, and 1.5 the feeding period were extended to 8 weeks. The data were subjected to analysis of variance by the completely randomized design. The results showed the presence of a number of fungi especially the type of Aspergillus flavus genus that reaches 40%. All aflatoxine dose levels significantly (P < 0.05) decreased live weight, it was also noticed that there were higher significant decrease in feed conversion when aflatoxine level was elevated in the feed. Increasing mortality with each increasing in aflatoxine level, the low level of chronic aflatoxine in the diets caused increased in the relative weight of internal organs (Liver, Pancreases, spleen, heart, gizzard, fibresia gland) as a results of aflatoxine presence in the diet, the low level of chronic aflatoxicosis for long time decreased in packed cell volume percentage, heamoglbulin concentration and red blood cell cont., with increase in white blood cells and (neutrophil, Hetrophil, Lymphocyte). The aflatoxine increased the serum concentration of protein, albumin, Cholesterol, Phosphor the activity of LDH, GOT, GPT, AIKP.
The performance of composite prestressed concrete beam topped with reinforced concrete flange structures in fire depends upon several factors, including the change in properties of the two different materials due to fire exposure and temperature distribution within the composition of the composite members of the structure. The present experimental work included casting of 12 identical simply supported prestressed concrete beams grouped into 3 categories, depending on the strength of the top reinforced concrete deck slab (20, 30, and 40 MPa). They were connected together by using shear connector reinforcements. To simulate the real practical fire disasters, 3 composite prestressed concrete beams from each group were exposed to high t
... Show MoreAbstract
The aim of this paper is to investigate and discuss the mechanisms of corrosion of epoxy coatings used for potable water tanks. Two distinct types of Jotun epoxy coatings: Tankguard 412 contained polyamine cured epoxy and Penguard HB contained polyamide cured epoxy, were tested and studied using the electrochemical impedance spectroscopic (EIS) method. The porosity of epoxy coatings was determined using EIS method. The obtained results showed that the two epoxy coatings have excellent behavior when applied and tested in potable water of Basrah city. Polyamine is more resistance to water corrosion compared to polyamide curing epoxy and has high impedance values. Microscopic inspection after te
... Show MoreImage compression is a suitable technique to reduce the storage space of an image, increase the area of storage in the device, and speed up the transmission process. In this paper, a new idea for image compression is proposed to improve the performance of the Absolute Moment Block Truncation Coding (AMBTC) method depending on Weber's law condition to distinguish uniform blocks (i.e., low and constant details blocks) from non-uniform blocks in original images. Then, all elements in the bitmap of each uniform block are represented by zero. After that, the lossless method, which is Run Length method, is used for compressing the bits more, which represent the bitmap of these uniform blocks. Via this simple idea, the result is improving
... Show MoreThis paper proposes a novel finite-time generalized proportional integral observer (FTGPIO) based a sliding mode control (SMC) scheme for the tracking control problem of high order uncertain systems subject to fast time-varying disturbances. For this purpose, the construction of the controller consists of two consecutive steps. First, the novel FTGPIO is designed to observe unmeasurable plant dynamics states and disturbance with its higher time derivatives in finite time rather than infinite time as in the standard GPIO. In the FTGPO estimator, the finite time convergence rate of estimations is well achieved, whereas the convergence rate of estimations by classical GPIO is asymptotic and slow. Secondly, on the basis of the finite and fast e
... Show MoreA mathematical model has been formulated to predict the influence of high outdoor air temperature on the performance of small scale air - conditioning system using R22 and alternative refrigerants R290, R407C, R410A. All refrigerants were investigated in the cooling mode operation. The mathematical model results have been validated with experimental data extracted from split type air conditioner of 2 TR capacity. This entailed the construction of an experimental test rig which consists of four main parts. They are, the refrigeration system, psychrometric test facility, measuring instrumentation, and auxiliary systems. The conditioned air was maintained at 25 0C dry bulb and 19 0C wet bulb for all tests. The outdoor ambient air temperatur
... Show MoreThe thermal and electrical performance of different designs of air based hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and
... Show More