Preferred Language
Articles
/
bsj-895
The Datums Transformation for GPS Navigation Measurements Correction
...Show More Authors

The GPS navigation measurements become more widely used in many civilian and scientific application. All GPS navigation data holds many errors, the main error sources arise from the geodetic Datum variation when user apply the GPS measurements with the map. Geodetic datums define the size and shape of the earth and the origin and orientation of the coordinate systems used to map the earth surface. In this paper, the Datum transformation was evaluated in two mathematical methods to overcome the errors due to the difference between the WGS-84 and our country Datum Clarck-1880. The results was evaluated and investigated using Carmin GPS device for GCPs comparison, topographic map for Hilla city, mid Iraq 1:100000 scale, and two georefrencing ETM+ & TM satellite images. The spatial transformation error was less than 10 meter for UTM projection & less than 1 sec for (?, ?) projection, which can considered as suitable results in transformation calculation All results were overcome using two written program for each method with the help of Matlab facility. GPS: Global Positioning System, GCPs: Ground Control Points

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 28 2018
Journal Name
Iraqi Journal Of Science
Remove Reflection Using Wavelet transformation Estimation
...Show More Authors

     Improving the performance of visual computing systems is achieved by removing unwanted reflections from a picture captured in front of a glass. Reflection and transmission layers are superimposed in a linear form at the reflected photographs. Decomposing an image into these layers is often a difficult task. Plentiful classical separation methods are available in the literature which either works on a single image or requires multiple images. The major step in reflection removal is the detection of reflection and background edges. Separation of the background and reflection layers is depended on edge categorization results. In this paper a wavelet transform is used as a prior estimation of background edges to sepa

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Science
The effect of Serratia marcescens protease on human lymphocytes transformation
...Show More Authors

Fifteen blood samples were collected from healthy males and females (6 males &
9 females), average age (21-34 years) in heparinized sterile tubes. The extracellular
protease was extracted from a clinical isolate of Serratia marcescens that was
isolated from a patient suffering from urinary tract infection taken from the Central
Health Laboratory. The extracted protease was purified partial by two steps,
precipitation with 30-55% saturation of ammonium sulfate following with dialysis
and ion exchange chromatography DEAE-cellulose. The protease concentration was
0.15 mg/ml. Two concentration 0.258g/ml and 0.58/ml of protease were prepared
and applied in current study. Lymphocyte transformation test using whole b

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 29 2020
Journal Name
Iraqi Journal Of Science
Interpolation and Statistical Analysis for Evaluation of Global Earth Gravity Models Based on GPS and Orthometric Heights in the Middle of Iraq
...Show More Authors

The regions around the world need to perform their results based on the local geoid. However, each region has different ground topography based on the amount of gravity in this region. Nowadays, the recent global Earth's gravity model of 2008 is successfully used for different purposes in geosciences research. This research presents an overview of the preliminary evaluation results of the new Earth Gravitation Model (EGM08) in the middle of Iraq. For completeness, the evaluation tests were also performed for EGM96 by examining 31 stations distributed over four Iraqi provinces. The national orthometric heights were compared with the GPS /leveling data obtained from these stations. This study illustrated that the GPS /leveling based on EGM

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Crossref
Publication Date
Wed Feb 20 2019
Journal Name
Iraqi Journal Of Physics
The measurements of neutron Fermi Age for selected Nuclear Reactor shielding materials using the Indium foil technique
...Show More Authors

The Neutron Fermi Age, t, and the neutron slowing down density,   q (r, t) , have been measured for some materials such as Graphite and Iron by using gamma spectrometry system UCS-30 with NaI (Tl) detector. This technique was applied for Graphite and Iron materials by using Indium foils covered by Cadmium and the measurements done at the Indium resonance of 1.46 eV. These materials are exposed to a plane 241Am/Be neutron source with recent activity 38 mCi. The measurements of the Fermi Age were found to be t = 297 ± 21 cm2 for Graphite, t = 400 ± 28 cm2 for Iron. Neutron slowing down density was also calculated depending on the recent experimental t value and distance.

View Publication Preview PDF
Crossref
Publication Date
Sun Mar 17 2019
Journal Name
Baghdad Science Journal
Study of Aerodynamic Surface Roughness for Baghdad City Using Signal-Level Measurements
...Show More Authors

Roughness length is one of the key variables in micrometeorological studies and environmental studies in regards to describing development of cities and urban environments. By utilizing the three dimensions ultrasonic anemometer installed at Mustansiriyah university, we determined the rate of the height of the rough elements (trees, buildings and bridges) to the surrounding area of the university for a radius of 1 km. After this, we calculated the zero-plane displacement length of eight sections and calculated the length of surface roughness. The results proved that the ranges of the variables above are ZH (9.2-13.8) m, Zd (4.3-8.1) m and Zo (0.24-0.48) m.

View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Apr 16 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Using of the Correction Schwarzschild radius Equation and Its Application of the Black Holes
...Show More Authors

  This study is a try to compare between the traditional Schwarzschild’s radius and the equation of Schwarzschild’s radius including the photon’s wavelength that is suggested by Kanarev for black holes to correct the error in the calculation of the gravitational radius where the wavelengths of the electromagnetic radiation will be in our calculation. By using the different wavelengths; from radio waves to gamma ray for arbitrary black holes (ordinary and supermassive).
 

View Publication Preview PDF
Publication Date
Sun May 01 2016
Journal Name
Journal Of Engineering
Improving the Accuracy of Handheld GPS Receivers Based on NMEA File Generating and Least Squares Adjustment
...Show More Authors

This study aims to improve the quality of satellites signals in addition to increase accuracy level delivered from handheld GPS data by building up a program to read and decode data of handheld GPS. Where, the NMEA protocol file, which stands for the National Marine Electronics Association, was generated from handheld GPS receivers in real time using in-house design program. The NMEA protocol file provides ability to choose points positions with best status level of satellites such as number of visible satellite, satellite geometry, and GPS mode, which are defined as accuracy factors. In addition to fix signal quality, least squares technique was adopted in this study to minimize the residuals of GPS observations and enh

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 16 2021
Journal Name
Kufa Medical Journal
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer Lens Implantation for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat

... Show More
View Publication
Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Clinical and Refractive Outcomes of Toric Phakic Implantable Collamer lens Implantat for correction of myopic astigmatism
...Show More Authors

Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.

Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in  Eye Specialty Private Hospital, Baghdad, Iraq.

Type of the Study: a prospective non randomize intervention study.

Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Correction of Non-Uniform illumination for Biological Images Using Morphological Operation Assessing with Statistical Features Quality.
...Show More Authors

Non Uniform Illumination biological image often leads to diminish structures and inhomogeneous intensities of the image. Algorithm has been proposed using Morphological Operations different types of structuring elements including (dick, line, square and ball) with the same parameters of (15).To correct the non-uniform illumination and enhancement biological images, the non-uniform background illumination have been removed from image, using (contrast adjustment, histogram equalization and adaptive histogram equalization). The used basic approach to extract the statistical features values from gray level of co-occurrence matrices (GLCM) can show the typical values for features content of biological images that can be in form of shape or sp

... Show More
View Publication Preview PDF