Preferred Language
Articles
/
bsj-876
Spectrophotometric determination of Procaine penicillin in pure and pharmaceutical formulations using metol
...Show More Authors

A simple, accurate and sensitive spectrophotometric method for the determination of Procaine penicillin (PP) is described. The method is based on charge-transfer reaction of PP with metol (N-methyl-p-hydroxy aniline) in the presence of ferric sulphate to form a purple-water soluble complex ,which is stable and has a maximum absorption at 510 nm .A graph of absorbance versus concentration shows that Beer’s low is obeyed over the concentration range of 3-80 µg /ml of PP (i.e.,3-80 ppm) with a molar absorbativity of 4.945 ×103 L.mol-1.cm-1 ,Sandell sensitivity of 0.1190 µg cm-2 ,a relative error of (-1.57)-2.79 % and a standard deviation of less than 0.59 depending on the concentration of PP.The optimum conditions for full colour development are described and the proposed method was probably applied satisfactorily to pharmaceutical injections containing PP.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 01 2025
Journal Name
Journal Of Physics: Conference Series
Determination of Radioactivity Levels in Some Rice Samples available in the Iraqi Markets Using the system of High-purity Germanium
...Show More Authors
Abstract<p>This study aimed to determine the radioactivity and radiation hazard indicators of rice samples potentially for human consumption. Gamma spectroscopy was used to calculate the specific activity of natural and artificial radionuclides (<sup>238</sup>U, <sup>232</sup>Th, <sup>40</sup>K, and <sup>137</sup>Cs) in local and imported rice samples collected from local markets in Baghdad Governorate, Iraq, in addition to various radiological hazard indices. The radionuclide concentrations in the samples varied from 2.123 ± 1.457 Bq/kg to 13.032 ± 3.610 Bq/kg for <sup>238</sup>U, 2.906 ± 1.705 Bq/kg to 17.290 ± 4.158 Bq/kg for <sup>232</sup></p> ... Show More
View Publication
Scopus Crossref
Publication Date
Tue Jan 09 2018
Journal Name
World Rural Observations
Solid cartridges in Determination of Benzidines in River and Wastewater by HPLC
...Show More Authors

A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS

... Show More
Publication Date
Mon Dec 25 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetry and Indirect X-ray Fluorescence Determination of Active Ingredients in Tetracycline Hydrochloride Drug and Injection Solution of B12 Vitamin Using of Polyurethane Foam Sorbents
...Show More Authors

The simple and available technique of colorimetry and indirect X-ray fluorescence determination of tetracycline hydrochloride (in the form of colored complex with iron(III) ions) and cyanocobalamine (in the form of the colored thiocyanate complex with cobalt(II) ions) is offered. The analytes were separated from the accompanying components by sorption to polyurethane foam based on ethers. The conditions of sorption separation and measurement of analytical signal of these substances are optimized. The obtained results of tetracycline drugs and injection solution B12 vitamin are in satisfactory agreement with data declared by the manufacturer.

View Publication Preview PDF
Crossref
Publication Date
Thu Jan 02 2020
Journal Name
Journal Of Research In Medical And Dental Science
Assessment of Surface Roughness and Surface Wettability of Laser Structuring Commercial Pure Titanium
...Show More Authors

Aim: To evaluate the commercial pure titanium disks that structuring by laser in two design (dot and groove) each one with three different laser scan (5, 15 and 25) and comparing with titanium surface that not subjected to any surface structuring (control) through measuring the wettability test and surface roughness test. Materials and methods: Structuring on the surface of the commercial pure titanium (CP Ti) disks was performed via using fiber laser CNC machine in two design (dot and groove) in three different laser scans (5, 15 and 25), then the structuring disks analyzed with the control group by atomic force microscope and water contact angle test. Results: The results of this study showed that the surface roughness and the wettability

... Show More
Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
Journal Of Physics: Conference Series
Determination of the Fertility of Southern Iraqi Soil Using Laser - Induced Breakdown Spectroscopy System
...Show More Authors

In this work, seven soil samples were brought brought to study and analyses the element concentrations from different southern regions of Iraq using laser-induced breakdown spectroscopy (LIBS) technique. It has been documented as an atomic emission spectroscopy (AES) technique. Laser-induced plasma utilized to analyze elements in materials (gases, liquids, and solids). In order to analyze elements in materials (gases, liquids, and solid). The Nd: YAG laser excitation source at 1064 nm with pulse width 9 ns is used to generate power density of 5.5 x 1012 MW/mm2, with optical spectrum in the range 320-740 nm. From this investigation, the soil sample analysis of the southern cities of Iraqi, it is concluded that the rich soil element of P, Si,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Dec 11 2018
Journal Name
Iraqi Journal Of Physics
Preparation and study the structure of pure and impure barium titanate with Mg2+ ion
...Show More Authors

Pure and doped barium titanate with Mg2+ ion at two molar ratios x= (5%, 10%) mol. has been synthesized by solid state reaction technique. The powders sintered at two temperatures (1000 °C and 1400 °C). An XRD technique was used in order to study the crystal structure of pure and doped barium titanate, which confirmed the formation of the tetragonal phase of BaTiO3, and then calculate the lattice parameters of pure and doped barium titanate, the addition of magnesium ion Mg2+ can lead to decreases lattice parameters.

View Publication Preview PDF
Crossref
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Preparation and study the structure of pure and impure barium titanate with Mg2+ ion
...Show More Authors

Pure and doped barium titanate with Mg2+ ion at two molar ratios x= (5%, 10%) mol. has been synthesized by solid state reaction technique. The powders sintered at two temperatures (1000 °C and 1400 °C). An XRD technique was used in order to study the crystal structure of pure and doped barium titanate, which confirmed the formation of the tetragonal phase of BaTiO3, and then calculate the lattice parameters of pure and doped barium titanate, the addition of magnesium ion Mg2+ can lead to decreases lattice parameters.

View Publication Preview PDF
Crossref
Publication Date
Fri Jan 17 2025
Journal Name
African Journal Of Biomedical Research
Digital Evaluation of Cuspal Deflection of Endodontically Treated Teeth Restored with Resin Composite and Different Fiber Formulations
...Show More Authors

Background: This study evaluated the influence of different fiber formulations incorporation in resin composite on cuspal deflection (CD) of endodontically-treated teeth with mesio-occluso-distal (MOD) cavities. Materials and Methods: Thirty-two freshly extracted maxillary premolar teeth received MOD cavity preparation followed by endodontic treatment using single cone obturation technique, and divided into: Group I: direct composite resin only using a centripetal technique, Group II: direct composite resin with short fiber-reinforced composite (everX Flow), Group III: direct composite resin with leno wave ultra-high molecular weight polyethylene (LWUHMWPE) fibers placed on the cavity floor, and Group IV: direct composite resin with LWUHMWP

... Show More
Preview PDF
Publication Date
Sun Dec 04 2016
Journal Name
Baghdad Science Journal
Mefenamic Acid Selective Membranes Sensor and Its Application to pharmaceutical Analysis
...Show More Authors

PVC membrane sensor for the selective determination of Mefenamic acid (MFA) was constructed. The sensor is based on ion association of MFA with Dodecaphospho molybdic acid (PMA) and Dodeca–Tungstophosphoric acid(PTA) as ion pairs. Nitro benzene (NB) and di-butyl phthalate (DBPH) were used as plasticizing agents in PVC matrix membranes. The specification of sensor based on PMA showed a linear response of a concentration range 1.0 × 10–2 –1.0 × 10–5 M, Nernstian slopes of 17.1-18.86 mV/ decade, detection limit of 7 × 10-5 -9.5 × 10 -7M, pH range 3 – 8 , with correlation coefficients lying between 0.9992 and 0.9976, respectively. By using the ionphore based on PTA gives a concentration range of 1.0 × 10–4 –1.0 × 10–5 M,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 12 2021
Journal Name
Pollution Research
DETERMINATION OF ANILINE IN WASTEWATER BY CLOUDPOINT EXTRACTION FOLLOWED BY HPLC USING 8-HYDROXYQUINOLINE AS A DERIVATIZATION AGENT
...Show More Authors

A procedure, depending on the derivatization and determination of aniline was depicted andvalidated in this study. 8-hydroxyquinoline (8-HQ) was used as the derivatizing agent for thedetermination of aniline. An optimization study was performed for the derivatization reaction, i.e.,the diazonium coupling reaction, the optimum parameters were as follows: 22 mM of hydrochloricacid, 54mM of sodium hydroxide, and 1.8mM of sodium nitrate. The optimization study of themethod of cloud point extraction (CPE) revealed that the extraction solvent was 0.5 ml of Triton X-100, the optimum temperature was 90 °C, and the incubation time was 25 min. The linearity,correlation coefficients, molar absorptivities, and limits of detection were improved using t

... Show More