Preferred Language
Articles
/
bsj-870
Three-Dimensional Microfabrication With Conjugated Polymers
...Show More Authors

In this paper we reported the microfabrication of three-dimensional structures using two-photon polymerization (2PP) in a mixture of MEH-PPV and an acrylic resin. Femtosecond laser operating at 800nm was employed for the two-photon polymerization processes. As a first step in this project we obtained the better composition in order to fabricate microstructers of MEH-PPV in the resin via two-photon polymerzation. Acknowledgement:This research is support by Mazur Group, Harvrad Universirt.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
College Of Islamic Sciences
AYĀT AL-HUJJAH FĪ SŪRAT AL-ANĀM RIWĀIAH WA DERĀIAH ( a model in three verses from Surat Al-An’am 108-110)
...Show More Authors

 

The current research discusses the jurisprudence of the argumentative meaning in the Qur’an, and it is one of the general methods of responses in the Qur’an, as well as the argumentative approach to the recitations of the readers and directing their meanings. I have chosen a model for three verses from Surat Al-An’am, in which there are seven frequent recitations and seven odd ones, on a topic related to theology and faith; It forms the centerpiece of the argument verses in Surat Al-An'am; It contains the jurisprudence of dealing with infidels and dissenters, turning away and forbidding insulting what they claim besides God in the event of corruption, and God Almighty’s decree and wisdom in the occurrence of unbeli

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Xlinguae
The three-level phono-grammar order and its derivational connecting link: the elements of language system (on the material of Arabic)
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
International Journal Of Drug Delivery Technology
Phytochemical Investigation and Pharmacological Activity of Solidago canadensis L. against H1N1 Virus, involving the Separation and Identification of Three New Compounds
...Show More Authors

Scopus
Publication Date
Sat Sep 28 2024
Journal Name
Journal Of International Dental And Medical Research
Effect of Air–Particle Abrasion of Dentin Surface on Shear Bond Strength of Lithium Disilicate to Dentin Using Three Different Cements
...Show More Authors

This study aims to evaluate the influence of the air abrasion of dentin on the shear bond strength of lithium disilicate using three different types of luting cements. Sixty cylindrical specimens were milled from lithium disilicate CAD/CAM blocks (IPSe.max CAD). Sixty sound human maxillary premolar teeth were decoronated to the level of peripheral dentin, then randomly divided into three groups according to the type of luting cement used for the cementation of the lithium disilicate specimens (n = 20); Group A: Glass ionomer cement (Riva Self- Cure); Group B: Adhesive resin cement (Rely X Ultimate); Group C: Self-adhesive resin cement (Rely X U200). Each group was then further subdivided into two subgroups (n=10); Subgroups AI, BI, and CI,

... Show More
Preview PDF
Scopus
Publication Date
Mon Mar 07 2022
Journal Name
Journal Of Educational And Psychological Researches
Math Word Problems in Mathematics Books for the First Three Grads of the Basic Stage in Palestine (An analytical and Evaluative Study)
...Show More Authors

This study aimed at revealing the degree of availability of standards of word problems in mathematics books for the first three grades of the basic stage in Palestine. For this purpose, the researcher prepared an analysis tool and a list of criteria consisting of two areas: linguistic formulation and mathematical content. Every area had seven items. The results of the study showed that the third-grade mathematics book has the highest degree of availability of the standards with 85.75%, and then came the second-grade mathematics book with 83.12%. Finally, the first-grade mathematics book came with 80.13%. In the light of the previous results, the researcher recommended to develop the language of word problems, to take into account their i

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 27 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of curvature angle and rotational speed on the cyclic fatigue of three types of rotary instrument (In vitro): comparative study
...Show More Authors

Background: The fracture of instruments within root canal during endodontic treatment is a common incidence, fracture because of fatigue through flexure occurs due to metal fatigue, this study aimed to assess the effect of curvature angle and rotational speed on the cyclic fatigue of different type of Endodontic NiTi Rotary Instruments and compare among them. Materials and method: Three types of rotary instruments with tip size 0.25: ProTaPer F2 (Densply, Malifier) Revo-S SU( 0.06 taper, MicroMega) and RaCe system (0.06 taper, FKG, Dentaire), Forty file of each instrument were used within two canals with angle of curvature (40 &60 )at two speed (250&400)RPM, twelve group were formed for all instruments(total number=120),ten file fo

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro Comparative Assessment Of The Effect Of Gutta-Fusion Obturation On The Push Out Bond Strenght Of Three Types Of Sealers
...Show More Authors

Background: The bond strength of the root canal sealers to dentin is very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate and compare the push-out bond strength of root filled with total fill Bioceramic, AH Plus and Gutta-flow®2 sealers using GuttaFusion®obturation system versus single cone obturation technique. Materials and method: sixty of mandibular premolars teeth with straight roots were used in this study, these roots were instrumented using Reciproc system, instrumentation were done with copious irrigation of 3 mL 5.25% sodium hypochlorite solution (NaOCl) during all the steps of preparation, and smear layer will be removed with 1 ml of 17% EDTA kept in

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Global Pharma Technology
Study of the genetic diversity in three species belonging to family: Daphniidae (Crustaceae, Cladocera) collected from different regions in Baghdad Province/Iraq
...Show More Authors

Scopus (2)
Scopus
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro Comparative Assessment of the Effect of Gutta-Fusion Obturation on the Push Out Bond Strength of Three Types of Sealers
...Show More Authors

Background: The bond strength of the root canal sealers to dentin is very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate and compare the push-out bond strength of root filled with total fill Bioceramic, AH Plus and Gutta-flow®2 sealers using GuttaFusion®obturation system versus single cone obturation technique. Materials and method: sixty of mandibular premolars teeth with straight roots were used in this study, these roots were instrumented using Reciproc system, instrumentation were done with copious irrigation of 3 mL 5.25% sodium hypochlorite solution (NaOCl) during all the steps of preparation, and smear layer will be removed with 1 ml of 17% EDTA kept in

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Oral Medicine And Oral Surgery
Evaluating dental implant stability using three devices Osstell<sup>®</sup>, Periotest<sup>®</sup>, and AnyCheck<sup>®</sup>: a clinical study
...Show More Authors

Introduction: Implant stability is usually measured with resonance frequency analysis (RFA) and damping capacity assessment (DCA). This study aimed to measure primary and secondary stabilities using 3 devices that are based on these methods, namely; RFA (Osstell®) and DCA (Periotest® and AnyCheck®) to assess the correlations of the measurements obtained by these devices and the correlations between implant stability and insertion torque. Material and Methods: This observational prospective study included 35 dental implants. The implant stability was measured using the 3 devices. Mann–Whitney U

... Show More
View Publication
Crossref (1)
Scopus Crossref